This microwave surface light bulb (120v 25w) is an OEM replacement part used in microwaves and microwave/hood combos. It is one of the two halogen lightbulbs that are positioned on either end of the base of the appliance to illuminate the cooking surface. The light allows you to easily monitor the cooking/heating process. Over time the li...Read moreght bulb may burn out or break resulting in difficulty viewing the cooking surface, and increased chances of injury while cooking. To replace the bulb, unplug the appliance and remove the light cover/lens, to access the bulb housing. Carefully unscrew the old bulb from its socket to avoid breaking it and damaging the assembly. Inspect the socket to check that it is in good working condition. If both of your light bulbs fail at the same time, the socket may be experiencing an electrical fault and will need to be replaced. Install the new bulb by screwing it into the socket. Reattach the light cover and plug in the appliance to check that the light bulb is functional. Each light bulb is sold individually.
The glass turntable tray rotates food in the microwave to ensure even heating. Designed for compatibility with specific models, it provides a stable surface for cookware. Check fitment before ordering, as trays may vary slightly in size and configuration.
This diode, or high voltage diode, is used in microwaves. It is an electrical current control device that ensures power flows in one direction and not the other way. If your microwave produces no heat, heats inconsistently, or gets noisy, replacing this part can be the solution. The tools needed for this replacement are a nutdriver, plier...Read mores, and screwdrivers. First remove the microwave cover, then remove the old part by disconnecting the small thermostat. Replace with the new diode. Remember to use the diagram provided by the manufacturer for more instructions.
If your microwave is not turning on it could be due to your fuse needing to be replaced. This part protects the microwave by shutting it off if there is an electrical surge. This fuse is just over an inch long, is metallic on both ends and ceramic in the middle. Before beginning this repair, unplug the appliance and wait a few minutes bef...Read moreore starting. Remove the outer cabinet which is held in place with two screws. You will then locate the power cord which will lead you to the fuse holder. Determine if the fuse has blown. Using an ohmmeter, you should be able to figure out if it has blown. A proper reading is zero ohms, if it reads as anything else then your fuse has in fact blown. Simply snap the old fuse out of place and place the new one in.
This damper is an authentic OEM replacement assembly used in microwave/range hood combos. It includes the damper door and frame. It is designed to direct the flow of air through the vent duct, and the release of steam and heat from the appliance during cooking. Over time, the damper door and frame can wear down or become obstructed by foo...Read mored particles and debris. A faulty damper assembly will result in poor ventilation, uneven cooking, and excessive moisture buildup which can damage internal components in the appliance. Disconnect any wires or connectors attached to the faulty damper assembly and remove it from the appliance. Position the new damper assembly and reconnect the wires/connectors before securing it with the appropriate fasteners.
This is a manufacturer-approved mounting kit for your microwave. This kit is crucial for keeping your microwave securely wall-mounted. This kit does not include the mounting plate itself. This kit comes in handy if you buy your microwave separately from the mounting kit.
This mounting plate provides a secure foundation for attaching components within the appliance, ensuring proper alignment and structural stability. It is commonly replaced when wear, corrosion, or damage affects the secure installation of internal parts.
The Plate is listed for compatible Whirlpool range models. This part covers, supports, or finishes the named appliance area. Confirm its position, finish, and attachment points against the model-specific parts diagram. Use the full model number to confirm fit, finish, and mounting position before ordering. This is a genuine OEM part sourced directly from the manufacturer.
Ask our experts a question about this model and we'll get back to you as soon as possible!
We may have answered a similar question already! Search questions and answers left by others using simple keywords like "fit", "broken", "easy", or "quality" to find questions that match.
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Sort by:
Prev
1
Next
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Ken - For model number YWML55011HS3
December 12, 2022
little white button between door latchhes will not depress, not allowing door to close??
Hello Ken, thank you for reaching out. According to our research, the problem seems to be with the door interlock and you may need to replace it, the part number is PS12749558. If you need help placing an order for it, please feel free to give us a call. We look forward to hearing from you!
Microwave wont heat, slight burning smell when turned on and is noisy.
Hello Chris, thank you for your inquiry. The no heat and a burning smell may be coming from the Transformer PS12346470 or Magnetron PS12731283. We hope this helps.
Hi. My 5 yr old low profile whirlpool microwave is not heating. The light turns on and the table top spins as well but food doesn't heat at all. I'm wondering if it's worth fixing. Can you please provide thoughts?
Hi Satish,
Thank you for your question. If the microwave is not heating, we recommend checking the diode, the magnetron, and the fuse. Before checking these parts, we recommend unplugging the microwave from the electrical outlet and releasing the charge from the capacitor. To avoid injury, you will need to release the potentially dangerous charge from the capacitor by placing a screwdriver with an insulated handle across the terminals. Be careful not to touch the metal portion of the tool. We have included a link from our website with more information on how to release the charge. Once the charge has been released, you will need to test these parts for continuity with a multimeter on the Rx1 setting. For the diode, touch the probes to the terminals. Then reverse the probes to check for continuity in the other direction. You should receive a reading that shows continuity in one direction, but not the other direction. If your diode does not show continuity, or shows continuity in both directions, you will need a replacement high voltage diode. For the magneton, you should receive a reading of two to three ohms of resistance. Next, move one probe to touch the metal housing of the magnetron. This test should not indicate that continuity is present. If the results of your test do not match the results above, you will need a replacement magnetron. For the fuse you should receive a reading of zero. If you get any other reading, you will need a replacement fuse. We hope this helps!
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Microwave made very loud noise while on. No heat.
52 of 87 peoplefound this instruction helpful.
Sleiman from Miami, FL
Easy
More than 2 hours
Pliers, Screw drivers
Unless you have a very comfortable background with electronics and electricity, I don't necessarily recommend taking apart a microwave. If you are very handy and are going to be VERY cautious to follow the rules of discharging caps and testing voltages before moving forward, then go for it. That said, I took the microwave off and apart.
... Read more Not knowing where to find the parts, I was fortunate that the installer put the instruction book for the microwave inside the front vent slot above the touchpad for reference. it details the location of every part and it tells you very clearly what each part you test should show specific to this microwave on your multimeter. Find this guide online if you don't have it. Turn on the microwave for 20 seconds with a glass of water to make sure it's not heating - that with the noise means it's eeither the magnetron, cap, or diode. Read the notes on this site for all of the basic things to look for with the magnetron, diode, and capacitor. Once comfortable with the guide, locations of those devices, and how to test, then take it down and apart. Unfortunately, I didn't do all those things in that order, and it only wasted a lot of time trying to find the parts. Once I found the parts and put all the screws and covers back for all the areas that didn't need to be accessed for the repair, testing went quickly. The diode was bad. Ordered a new one and had it in 3 days or so. That means your microwave will be apart and sitting somewhere for a little while until you get the part and have time to repair it. Putting the diode back isn't too bad. Reassemble the microwave and put it back up again. If i had to do it again, it would take me 20 to 30 minutes once the microwave was down and on a table. Also, I used some bricks with towels over them or you could use some sawhorses to keep the microwave elevated so you can plug it in and run it after installing the new component. Again, make sure you discharge the cap before touching anything again even if you didn't run it, but just plugged it in.
Read less
Was this helpful?
Thank you for voting!
Humming sound, not heating.
43 of 63 peoplefound this instruction helpful.
Fausto from Miramar, FL
Easy
15 - 30 mins
Nutdriver, Pliers, Screw drivers
I turn off the income electricity by shutting down the corresponding circuit breaker. Then, I removed the control panel from the microwave which gave me access to the capacitor and adjacent diode. After that i unscrewed the defective diode and replaced it with the new one and BINGO!
Was this helpful?
Thank you for voting!
Microwave wouldn't turn on and found breaker been tripped and then microwave wouldn't turn on at all.
31 of 55 peoplefound this instruction helpful.
Daniel from DECATUR, GA
Easy
30 - 60 mins
Pliers, Screw drivers
Read some instructions and easily found the fuse. Replaced it. Still didn't work. Took control panel off to check door switches. Nothing I read mentioned a second fuse. Tested and it to had blown. Ordered another one. Popped them in. Done.