This part is a genuine manufacturer door interlock switch kit, also known as primary micro switch or microwave switch kit, for a microwave. The function of this part is to sense when the door of the microwave is open or closed. If the part is defective, the microwave will not start or will start when door is open. This kit contains two 15...Read more Amp, 125/250 Volt switches with 3/16 inch terminals. Be sure to disconnect power to microwave before replacing part. Use extreme caution when replacing microwave parts, as high-voltage capacitors can retain an electrical charge when unplugged. NOTE: This kit includes 2 single pole, double throw (SPDT) micro switches. As per the manufacture for the secondary interlock switch order part # 56001100.
This screw is for microwaves.
A qualified technician should install this part if it requires accessing internal components of the microwave or microwave door. High-voltage capacitors can retain a lethal electrical charge even when the microwave is unplugged, and door shielding components should be tested for leaks after all door repairs. This screw is sold individually.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Microwave worked intermittently depending on how door was closed
67 of 85 peoplefound this instruction helpful.
Robert from Bainbridge Island, WA
A Bit Difficult
30 - 60 mins
Pliers, Screw drivers
Remove top grille (2 screws), undo control panel (1 screw). Tilt down control panel, switches are on the left. There are actually three switches that are involved with the door, two horizontally mounted, one vertically mounted. This would be an EASY REPAIR, but it took me a while to figure out which of the three switches was bad, and a
... Read morelso took a while to figure out that there is a plastic rod that inserts through the hole in the switch body. Once i figured this out went like a breeze. Lower horizontal switch was the bad one, but since the kit came with two switches i went ahead and replaced the upper horizontal one as well. IT appears that the horizontal switches are probably more likely to fail than the vertical switch based on the position of the switch and force angles. Works great now!
Read less
Was this helpful?
Thank you for voting!
Microwave went dead while in use.
35 of 42 peoplefound this instruction helpful.
Keith from Georgetown, TX
Really Easy
15 - 30 mins
Pliers, Screw drivers
1. removed vent across the top to gain excess to Screw holding control in place. 2. Removed control panel to access Fuse. 3. Remover fuse after pulling plug. 4.Tested fuse for continuity with volt ohm meter noting no continuity.5. Orderd new fuse. 6. receeived new fuse and installed infuse holder.7. plugged microwave plug back in receptic
... Read moreal and tested unit now working OK.Reversed steps 2 & 1 job complete
Read less
Was this helpful?
Thank you for voting!
Close the door on the microwave, punch in the # nothing happened
15 of 23 peoplefound this instruction helpful.
Robert S. from Stafford, TX
Really Easy
15 - 30 mins
Screw drivers
I removed the unit from the wall. Took the cover off. Set the unit on its side. It revealed the working parts. Removed the old micro switches. Put in the new oness. Presto, it worked. Very easy for me. The parts was delivered almost before my notice they were shipped.