This ice and water filter helps reduce impurities in select side by side and bottom freezer refrigerators. Replace it about every six months, or when water flow slows, ice production drops, or the filter light turns red. Some older filter setups may need an adapter. Place a cloth under the filter before removal. Check the exact refrigerator model before ordering.
The ice bucket auger is located within the ice bucket assembly in your freezer. It stirs and dispenses the ice in the bucket. You may need to replace the auger if your ice maker is noisy, or not dispensing ice. Disassembly of the ice bucket assembly is necessary to replace this part. Turn off power to the appliance before removing the ice bucket assembly to do this repair.
This temperature sensor, also called a thermistor, measures temperature inside the refrigerator or freezer and sends readings to the main control board. The board uses this information to control cooling, including compressor and fan operation. Incorrect readings may cause the compartment to become too warm or too cold, or make cooling ru...Read moren longer than needed. The replacement includes the sensor body and wire leads. Its location varies by appliance. This is an OEM part sourced directly from the manufacturer.
This defrost termination thermostat (Defrost Limiter Thermostat, High Limit Thermostat, Refrigerator Defrost Bi-Metal Thermostat) acts as a safety device to stop the evaporator coil from overheating, by turning off the defrost heater at the end of the defrost cycle. This part attaches to the tubing of the evaporator coil in the freezer. A...Read more faulty defrost termination thermostat may result in the defrost heater never heating and a solid frost buildup on the evaporator coil, which results in too warm temperatures. The thermostat contacts are normally closed and have continuity until it reaches 140 degrees. If this high limit thermostat is open at room temperature or colder, it is defective. This limit thermostat has an attached mounting clip and comes with pink and amber wire leads. The thermostat is 1 inch in diameter and 1/2 inch thick, the 2 wire leads are 10 inches long.
If your refrigerator is leaking, the dispenser is not dispensing, or the ice maker is not making or dispensing ice, the inlet valve may be involved. It controls water flow to the refrigerator’s water system and includes a guard. Check water pressure first; if it is sufficient, test valve continuity with a multimeter. Disconnect power befo...Read morere testing or replacing the valve. The inlet uses a 1/4-inch compression fitting, with 1/4-inch and 5/16-inch John Guest outlets. Confirm fit for your refrigerator.
This refrigerator ice maker assembly automatically freezes water and releases crescent-shaped ice cubes into the storage bin. It replaces an existing ice maker that has stopped cycling, fails to release ice, or has damaged components. Poor ice production can also result from a restricted water supply or incorrect freezer temperature, so c...Read moreheck these conditions before replacing the assembly. Confirm the mounting arrangement, fill cup position, electrical connections, and included adapters against the appliance parts list to ensure the kit matches the original installation. This is an OEM part sourced directly from the manufacturer.
Warm, moist air stays out of the ice chute when this refrigerator dispenser door flapper closes against the opening. The flap opens during ice dispensing, allowing cubes to pass through, then returns to form a seal when dispensing ends. A cracked, warped, or damaged sealing edge may leave gaps that contribute to frost, condensation, or dr...Read moreipping around the chute. Replacing a damaged flapper helps restore proper closure and reduces air leakage between the freezer and room while the dispenser is idle. This is an OEM part sourced directly from the manufacturer.
This ice dispenser solenoid moves the linkage that opens the ice chute door when dispensing is activated. When power is released, the mechanism allows the flap to close and limit warm air entering the freezer. A failed or sticking solenoid may prevent ice from dispensing or leave the chute door open, contributing to frost or moisture buil...Read moredup. Inspect the solenoid, spring, and door linkage before replacement, since other mechanism faults can cause similar symptoms. Disconnect power before accessing the dispenser assembly and follow the appliance instructions for mounting and wiring. This is an OEM part sourced directly from the manufacturer.
This electronic board (Main Control Board Assembly, Control Board, Motherboard) controls the temperature and defrost functions of the unit. This control board is located on the back of the refrigerator, and measures 8 inches by 5 inches. It’s constructed of metal and plastic, and comes in green. This kit includes one main control board wi...Read moreth built in defrost controls. If broken due to electrical surges or normal use, your fridge may experience temperatures that are too warm or too cold, or inconsistent defrost cycles. If this happens, the part should be replaced.
This defrost heater and bracket assembly melts frost from the evaporator coils during the automatic defrost cycle. Clearing the frost allows air to move across the cooling surface and through the refrigerator compartments. A failed heater may allow ice to build up, restricting airflow and leaving the fresh food or freezer section too warm...Read more. The appliance may also run longer without reaching the set temperature. Confirm the heater fault before replacement, since the thermostat and defrost control can cause similar symptoms. Disconnect power before accessing the assembly. This is an OEM part sourced directly from the manufacturer.
This is the replacement dairy door for a refrigerator. It is installed on the inner door and rotates up and down to allow access to the dairy compartment. It is made of clear plastic. If your dairy door is cracked, broken, missing, or won't stay on, you may need to replace it. This is an OEM part sourced directly from the manufacturer.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Refrigertor water dispenser not working BUT ice machine is working
1038 of 1163 peoplefound this instruction helpful.
ralph from bristow, VA
Really Easy
Less than 15 mins
Nutdriver, Screw drivers, Socket set
The very first symptom here is important! The door water dispenser is not working but the ice macine is working. You may only have a frozen water tube in the door so do the following before diagnosing that your solenoid valve is bad: 1) the tube usually runs under the front of the refrigerator and usually has a quick disconnect. Undo t
... Read morehe connection and press the dispenser. If water comes out of the tube you have a frozen or blocked tube in the door. 2) Immediately adjust the temperature in the freezer and warm the freezer compartment as much as you can without destroying the freezer contents. Wait 24 hours. This will usually unfreeze the line. Do not waste your time with a hair dryer. NOW, if this doesn't work and you are convinced you need to order and replace the solenoid, follow these steps. Assemble your tools first. I needed a good ratchet set and a screwdriver. A shop towel is helpful for spilled water. A light is handy. Pull out the refreigerator to gain access to the rear of the unit. Unplug the power and close the water valve (older homes, you may need to actually shut the house water supply). Remove the screws which hold the cover over the lower half of the refrigerator. On the left you will see the solenoid. It's always good to see that your new part matches the one you feel needs replaced. They may not match perfectly due to changing design but they should be very similar. One screw holds this part in place and access is very simple. Now simply unplug the electrical connections. In my case, one blue "blade" type connection (powering the water) and one red "blade" type connection powering the ice maker. They are not the same size and this coupled with the coloring means you will not accidently switch them. pull the tubes clear of the solenoid. This is simple and needs no explantion. Grab your new solenoid and reattach both the electrical and water lines (two, remember, ice maker and drink dispencer). Replace the single screw. Re-attach the rear, lower refrigerator cover and go to the front of the unit to check the water. You can listen carefully and hear the power engage from the new part bringing you water. Clean up, replace the refrigerator back to its place and look really tired when your wife sees that you worked "so hard"! You probably saved at least $50-$80 from a service call which can now be used to take the family to dinner after your "exhausting" 15 minute workout of removing about 10 screws and wheeling the unit in and out of place. Writing this article took longer! My 4 year old worked harder holding the flash light!
Read less
Was this helpful?
Thank you for voting!
Plastic Auger blades broke in ice tray
586 of 630 peoplefound this instruction helpful.
Tim from Newport News, VA
A Bit Difficult
30 - 60 mins
Pliers, Screw drivers
I used a digital camera and photographed the assembled unit and the metal blades before I started the repair. Then, I removed the top screw on the clear shield. Flip over ice tray and removed two Phillips screws on bottom. Exterior plastic white cover comes off next. The cover sides have hard push-in white plastic tabs. Push them in; pry
... Read moreup top cover with small flathead screwdriver. Slide white top cover up and you will now see the metal blades and assembly. Auger is held in place with a metal c-clip and washer on the end. Use flat head screwdriver to pry off c-clip. Then you will see a nylon round slotted nut. The threads are reverse, use pliers and loosen nut. It is not that tight but pliers are needed. Then it all is loose and ready for removal. I slid all the blades off at one time and kept them stacked together. Slide out auger and clear flat shield cover. Install new auger, clear shield, and metal blade stack. When you put it all back together take a look at the long metal J-hook on the bottom make sure it is in the slot before you make everything tight. Failing to do this will prevent cubed ice from dispensing. It is not that hard to do the repair it just takes some patience and paying attention to details.
Read less
Was this helpful?
Thank you for voting!
Fridge too warm, evaporator icing up
606 of 738 peoplefound this instruction helpful.
Gerald from San Clemente, CA
Easy
15 - 30 mins
Screw drivers
After replacing the defrost heater, main board and thermistor I still had the same problem. Called a repair guy and he (with the help of GE on the phone) diagnosed that the temperature sensor was bad. So I ordered from partselect and installed it and it fixed the problem. Been good for a couple months (knocking on wood). To install I
... Read morehad to cut the 2 wires to the old sensor, crimp the 2 new wires on and snap the new sensor to the clip on the evaporator. Very easy. Make sure you seal the ends of the wire crimps so moisture doesn't get in and corrode the connection.