The high-voltage capacitor is an electronic device that holds a charge of electricity in the high-voltage circuit of the microwave. The capacitor stores electricity similar to how a battery does, but can be charged and discharged instantly. If your microwave will not produce heat, there could be an issue with the capacitor. This genuine O...Read moreEM replacement high-voltage capacitor is approximately 5 inches long x 2 inches wide, and is compatible with most microwave brands.
NOTE: Make sure your microwave is unplugged, and that your capacitor is discharged before you begin this repair. A capacitor stores large amounts of electricity even after your microwave is unplugged.
This cord clip, also known as a strain relief, is used in microwaves, refrigerators and air conditioners. The clip holds the cord in a certain position to ensure that it is not strained. This extends the life of a power cord on your appliance and relieves tension. Refer to the manual provided by the manufacturer for further installation i...Read morenstructions and accurate guidance. As a safety precaution remember to unplug your appliance from the power source and wear work gloves to protect your hands.
This gasket is gray and is made of a spongy material. This gasket is used for many air conditioners. It will come to you at the length you specify: one foot, two feet, whatever you require. When ordering over the internet, requesting a quantity of one will result in you receiving one foot of this gasket. Requesting a quantity of two will result in you receiving two feet of this gasket, and so on.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
tray glass floor broke
4 of 8 peoplefound this instruction helpful.
Eduardo from baltimore, MD
Really Easy
15 - 30 mins
Remove old tray, clean old caulk, and clean inside of microwave, Place new tray-glass floor and caulk with heat resistant silicone. Easy project.
Was this helpful?
Thank you for voting!
broken tray-glass floor of microwave
3 of 5 peoplefound this instruction helpful.
ted from lagrange, KY
Really Easy
15 - 30 mins
very simple job. removed broken tray, inserted new tray and caulked around edges with a high heat resistant caulk.
Was this helpful?
Thank you for voting!
Magnetron shorted out blowed 15 amp fuse
3 of 8 peoplefound this instruction helpful.
Duane from Jacksonville, FL
Very Easy
1- 2 hours
Screw drivers, Socket set
removed cover of microwave, replaced fuse checked for short at plug with volt ohm meter, there was a short at the plug then checked magnetron for short and there was a short at the magnetron, the cap and diode checked good.