This part is a thermistor assembly and it works in conjunction with your room air conditioner. The thermistor is a sensor that attaches to the control board of your air conditioner. Once attached it will help regulate and monitor the temperature within the room. This model measures to be slightly under 20 inches in length, and it is black...Read more in color. The most common reason for needing to replace this part is if your appliance is no longer cooling properly. To replace this assembly, you will need a screwdriver set.
This control board, also known as a display board, is used for air conditioners. The control board regulates and carries the power to the various air conditioner components. If your control is defective or broken, it should be replaced or it will affect how your air conditioner functions. Check for other commonly defective parts that occu...Read morer before replacing the control board. Refer to the manual provided by the manufacturer for installation instructions and accurate guidance. Remember to unplug your appliance from the power source for safety before beginning this repair.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
accumulated condensation caused condenser fan failure
20 of 25 peoplefound this instruction helpful.
Sam from MCQUEENEY, TX
Easy
30 - 60 mins
Screw drivers
Pull the unit out of cabinet. Remove the brace between the blower housing and the condenser frame. Remove the screws securing the the condenser coil to the base and carefully lift and angle it just enough for the broken fan to clear ( be very careful with the refrigerant lines ). Slide the new fan back on the shaft and secure with the sp
... Read morering clamp. I used a pair of vice grips to compress the clamp, but be very careful because the clamp can exit the pliers, if the jaws are not perpendicular to the clamp. If you live in a area with high humidity remove the rubber plug at the back of the unit or the condensation will break your new fan. This fan needs some changes in design because the condensation puts too much stress on the plastic that contacts the motor shaft - some metal between shaft and the blades would help.
Part of the fan blade broke on my AC unit and was causing a vibration. This made the AC unusable. The ordered Fan was a perfect OE replacement. I simply removed the outside over and then the fan shroud inside the unit. I carefully repositioned the condenser unit being careful not to damage the fins. Using a pair of pliers, I removed
... Read morethe retainer clip and removed the old fan. The new fan slid right over the shaft. I replaced the retaining clip and then repositioned the shroud. Then I placed the condenser and fins back into place and then placed the cover back over the unit. Worked perfect. No issues. Take your time. Excellent replacement fan!
Read less
Was this helpful?
Thank you for voting!
Bad thermistor
1 personfound this instruction helpful.
Cindy from Baltimore, MD
Really Easy
15 - 30 mins
Screw drivers
Took front cover off air conditioner and pulled it a little forward out of the outdoor housing. I then flipped the LED display section out to the left and exposed the patch panel. The next step was to remove the panel with a small screwdriver and disconnect the old thermistor plug. I then plugged in the new one, remove the old one from th
... Read moree grid bracket and placed the new one in. I then replaced everything else in reverse order. I have two LG air conditioners and they both have the same connection setup.