Lcd Went Out On Control Panel
Step 1. Remove 3 screws holding above vent. Step 2. Remove single screw holding right side panel. Step 3. Unplug unit step 4. Lower panel. Will rest on lower pegs and wires. Step 5. Unplug control panel assembly. 5 Plugs. Remember location of each to replace when finished. Step 6. Remove entire panel carefully not to
... Read more
break off plastic teets holding panel in place. Step 7. Unscrew 4 screws whith phillips screwdriver holding panel assembly in place remembering how it goes. Step 8. Unfasten/plug lcd portion from control panel assembly. Step 9. Snap out lcd glass panel and remove entire unit. Step 10. Reverse each step in order. Be prepared to take your time and handle gently with care! Its not very difficult if you take your time, write down steps and draw diagrams if necessary. You can save alot of money by doing it yourself!
Read less
Parts Used:
-
David from Whitewater, WI
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
5 of 5 people
found this instruction helpful.