This light bulb is located on the inside of your microwave. The bulb is behind the top grill. It will need to be replaced when it has burnt out and no longer works. Unplug the unit before beginning this repair. Remove the top grill of your microwave, use your screwdriver to open the light socket, scrape off any silicone holding the bulb i...Read moren place, clean the area of any oil and dirt, insert the new bulb into the socket without touching the bulb, slide the holder back into place, line up the tabs on top of the metal plate, and secure the holder back into place.
This ceramic microwave fuse is just over an inch in length. It is white in the center, and metal on both ends. This is a 20-amp fuse, and is used to power your microwave. If the touch pad on the microwave becomes unresponsive, the microwave produces little to no heat, or the appliance simply does not turn on, it could mean that your fuse ...Read moreis at fault and needs to be replaced. Because this part contains an electrical charge, remember to disconnect power to the microwave unit before you begin this repair.
NOTE: Before you start this repair, ensure that the microwave is unplugged, and the capacitor is discharged. A capacitor stores large amounts of electricity even after your microwave is unplugged.
This switch monitor interlock is a critical safety component designed to ensure proper communication between the microwave door latch and the control board. When functioning correctly, it confirms that the door is securely closed before allowing the microwave to operate. A damaged or faulty switch may prevent the unit from starting, even ...Read moreif the door appears latched. Replacing this genuine part restores safe and reliable operation. Installation should be performed with care, and it's recommended to disconnect power before beginning any repair.
Introducing the GE Microwave Thermostat - a vital safety component for your microwave. Crafted with precision, this thermostat is specifically designed to prevent overheating scenarios which can cause hazards. Its main function is to promptly cut off power and shut down the microwave if a potential overheating problem is detected. Due to ...Read morethe potential risks associated with high-voltage capacitors within the microwave, the installation of this part should ideally be handled by a professional service technician. Invest in this GE Microwave Thermostat for optimal safety and maximum performance of your appliance. Trust GE for reliable and safe microwave operation.
This diode cable is a replacement electrical component designed to regulate current flow within an appliance circuit. It helps protect sensitive components and is commonly replaced when electrical faults or power irregularities occur. Proper application should be verified before installation.
If your microwave’s turntable isn’t rotating smoothly, the roller guide may be the issue. Positioned beneath the glass tray, this component helps ensure even spinning during operation. Designed for select models, it’s a direct replacement that restores proper movement and supports consistent heating. Be sure to check your microwave’s model number before purchasing to confirm compatibility.
This GE Turntable Shaft, also known as a Shaft Turntable, is an essential component for your microwave. Manufactured by trusted brand, GE, it is designed with precision to ensure your microwave's turntable rotates smoothly and efficiently. This high-quality piece sustained its function under regular wear and tear, ensuring long-lasting pe...Read morerformance and durability. It's perfect for when your existing shaft turntable needs replacement or simply an upgrade for optimal functionality. Trust your appliance's performance to the reliable build and design of GE products.
This capacitor delivers the electrical boost required for motors to start and operate efficiently. Proper capacitance reduces strain on motor components and helps prevent startup failures or inconsistent performance. Replacing a weakened capacitor restores smooth motor operation and supports long-term reliability.
Ask our experts a question about this model and we'll get back to you as soon as possible!
We may have answered a similar question already! Search questions and answers left by others using simple keywords like "fit", "broken", "easy", or "quality" to find questions that match.
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Sort by:
Prev
1
Next
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Susan - For model number PSB2201NSS02
June 2, 2023
My Convention component is broken including the cover plate
Hello Susan, thank you for reaching out. The parts you are looking for are the convection element, part number PS1018432, and the bottom panel, part number PS1016384. We hope this solves your problem!
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Microwave completely stopped working
968 of 1266 peoplefound this instruction helpful.
Kim from Cliffside Park, NJ
Really Easy
15 - 30 mins
Screw drivers
Turned out the issue was easily solved by replacing a single, inexpensive fuse.
First off, UNPLUG THE MICROWAVE.
The fuse is located under the plastic grill at the top of the microwave. It's held on by two screws. Once you've removed the screws and taken off the plastic grill, you go to the right side of the mic
... Read morerowave and remove another screw that holds a small metal grill in place. Removing the small metal grill is probably the toughest part of this repair. You kind of have to rock it back and forth a bit to get it to release. Once that's off, you can get to the fuse. I removed the burnt out one with a pair of needle nose pliers. I also put a small piece of cardboard under the fuse when I did this so I didn't accidentally drop it into the innards of the microwave. I did the same thing when I replaced the new fuse. I then plugged the appliance back in and made sure it worked. Once that was confirmed, I replaced both grills.
Read less
Was this helpful?
Thank you for voting!
Under the vent light bulbs needed to be replaced
66 of 87 peoplefound this instruction helpful.
Robert from Naples, ME
Really Easy
Less than 15 mins
Screw drivers
Turned of f the circuit breaker to the microwave. Unscrewed the cover (1 screw!) popped out the old bulbs and plugged in the new ones, using the bubblewrap as a handle to be sure my skin didn't touch the light bulbs so the oil from my hands didn't damage or shorten the life of the new bulbs. Turned the circuit back on. That's it!
Was this helpful?
Thank you for voting!
No power to microwave, no heating.
48 of 80 peoplefound this instruction helpful.
Michael from Coulterville, CA
A Bit Difficult
30 - 60 mins
Screw drivers
Unpluged power cord!! Removed front control panel to expose electronics (need to remove top horizontal vent cover to expose mounting hardware). Unplugged leads to control panel board. Removed magnetron with Tstat (3- phillip heads, need stubby). Installed new parts and control panel, plugged it in tested. Done.