MT700402 Campbell Hausfeld Compressor - Overview

Diagrams for MT700402

See every part. Know exactly what you need.

Enter a part description. DIY Heroes keep it simple, eg. "belt" or "pump".

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Regulator – Part Number: RE206203AV
$28.38
In Stock
Regulator
Part #RE206203AV
This is a genuine manufacturer sourced replacement regulator. It is specially designed for Campbell Hausfeld air compressors. This part adjusts the pressure of the air coming from the tank to the desired level. Please note, this only includes the metal regulator and the plastic knob. The valves, gauges and the pressure switch are all sold separately. To complete this repair you would need an a screwdriver, pliers and a set of wrenches. • First make sure to unplug the compressor • Drain the air from the tank • Disconnect all the valves and gauges from the regulator • Remove the old regulator • Secure the new regulator assembly • Reassemble and test the new regulator
Asme Safety Valve – Part Number: V-215100AV
$35.72
In Stock
Asme Safety Valve
Part #V-215100AV
This ASME safety valve is constructed of high-qualty metal, and is made for use with many air compressor models. Fastened to the manifold, the safety valve diminishes air pressure when the pump is not shut off at the proper setting. This important component is sold individually. A screwdriver, adjustable wrench and a pair of pliers are often necessary for the removal and replacement. Please refer to the specific manual for additional repair information.
Drain Valve – Part Number: SR060513SV
$17.98
In Stock
Drain Valve
Part #SR060513SV
This is a genuine Campbell Hausfeld replacement drain valve, sold individually. When using an air compressor, moisture naturally condenses inside the tank. If this water is left sitting for too long, it can lead to internal rust and damage. The drain valve allows you to release this built-up moisture easily. It's especially important to drain your tank after each use—particularly if you tend to leave air in the tank for extended periods. Regular draining helps extend the life of your compressor and maintain its performance. Be sure to open the valve regularly to prevent water buildup and potential tank corrosion.
Nipple – Part Number: HF002401AV-S
$6.40
In Stock
Nipple
Part #HF002401AV-S
This genuine OEM replacement nipple is designed for use in air compressors, serving as a critical connector between the pressure switch, the tank, and the regulator. A damaged or corroded nipple can lead to air leaks and inconsistent pressure, affecting overall performance. To check for leaks, apply soapy water to the fittings around the pressure switch and watch for bubbles. If replacement is necessary, the process typically involves disassembling the pressure switch. Begin by draining the tank using the valve at the bottom, then remove the coupler from the regulator and unthread the nipple. Access the wire connections by removing the pressure switch shroud, and carefully note the position of each wire before disconnecting them—starting with the motor wire, followed by the cord wires and ground wires. Remove the strain relief, pressure gauge, and the airline connecting the check valve to the switch. Finally, unthread the pressure switch from the tank nipple and remove the nipple itself. When reassembling, it is recommended to use thread tape to ensure a proper seal. This replacement part is sold individually.
Pressure Switch – Part Number: CW210100SJ
$137.12
In Stock
Pressure Switch
Part #CW210100SJ
This is a manufacturer sourced replacement part designed for use with Campbell Hausfeld air compressors. The pressure switch tells your compressor when to stop and when to start. There are multiple reasons a pressure switch could be leaking air. If it is leaking air the pressure switch should be replaced for a compressor to operate properly and safely. To complete this repair you would need: wrench set, nut driver set and a thread-sealing tape. • Shut off the electricity and drain the air tank • Remove the tank pressure gauge • Remove the pressure switch tube • Remove the pressure regulator assembly • Disconnect the wires • Remove the safety valve • Install the new pressure switch • Reinstall the safety valve • Connect the wires • Reinstall the pressure switch tube • Screw the pressure gauge onto the new pressure switch and tighten the gauge firmly • Test the air compressor
Gauge – Part Number: GA016313AV
$19.59
Special Order
Gauge
Part #GA016313AV
Reducer – Part Number: ST071407AV
$8.27
In Stock
Reducer
Part #ST071407AV
Sretainer Ring – Part Number: ST063100AV
No Longer Available
Sretainer Ring
Part #ST063100AV
Unloader Valve – Part Number: CW000800AV
$140.19
In Stock
Unloader Valve
Part #CW000800AV
Barb Fitting – Part Number: HF005000AV
$8.93
Special Order
Barb Fitting
Part #HF005000AV
Valve Inlet – Part Number: LT013400AV
No Longer Available
Valve Inlet
Part #LT013400AV
Check Valve – Part Number: CV221505SJ
$57.03
On Order
Check Valve
Part #CV221505SJ
This is an authentic Campbell Hausfeld replacement part manufactured for use with air compressors. The check valve prevents pressurized air from backing up into the pump from the tank and allows air to flow into the tank from the pump. It is a one-way valve. A bad check valve may not allow air into the tank causing the motor to run but not move the pump. The motor will make a buzzing sound and may eventually burn out. This check valve is available as an individual replacement part.

Watch our pros, then fix it yourself.