This OEM glass cooking tray is a removable glass plate, measuring 13 inches in diameter, that spins inside the microwave during operation. It ensures that heat is evenly distributed in the microwave to properly heat or cook the food. Over time, the heat generated in the microwave can cause the glass to warp and the plastic rollers to wear...Read more down. The glass can also crack or shatter accidentally. It is important to replace the glass as soon as it is no longer functioning well to prevent uneven heating and reduce any safety hazards from damaged glass. Carefully pull the old glass cooking tray from the microwave and clean the microwave cavity. Place the new tray onto the rotating mechanism, and properly align it with the rollers. Turn the microwave on and check to see that the tray is rotating freely.
This magnetron in your microwave creates the radiation needed for cooking or warming your food. It is located inside the main cavity, typically near the transformer or waveguide. When the magnetron becomes defective, your food may not heat up properly or heat up at all. Additionally, buzzing or humming sounds may be noticeable while the m...Read moreicrowave is in operation. With a malfunctioning magnetron, your microwave loses its primary function. To remove it, you first need to unplug your microwave from its outlet. Before touching any components, discharge the capacitor by placing a screwdriver, with an insulated handle, across the two terminals of the capacitor. Once the capacitor is discharged, replace the current magnetron by disconnecting it from any wires and removing any mounting screws or clips. This magnetron is sold individually and is supplied directly from the original equipment manufacturer.
Usually found kitchen appliances, this OEM-certified diode cable assembly helps to convert power from the transformer to the magnetron, to heat up your food. A damaged cable assembly will cause your appliance to heat food inconsistently or to not work at all. You might notice a burning smell or a loud buzzing sound coming from your applia...Read morence. If you do not replace a broken cable assembly, the components that produce heat in your appliance can overheat and fail. To replace your cable assembly, start by unplugging your appliance from any electrical source. Remove any protective casing from the assembly by unthreading any screws or clips. Disconnect the cable assembly from the transformer and the magnetron with pliers. Reinstalling a new cable assembly requires you to reverse the previous steps. Please keep in mind that this cable assembly is sold individually.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Broke the round glass tray
10 of 14 peoplefound this instruction helpful.
Eileen from DETROIT LAKES, MN
Very Easy
Less than 15 mins
new glass tray
Was this helpful?
Thank you for voting!
Magnitron failed
8 of 13 peoplefound this instruction helpful.
Joseph from WILTON, NH
A Bit Difficult
1- 2 hours
Screw drivers
Over the stove microwave installed in top cabinet row. 1. Unplug device. 2. Two people to remove from wall/cabinet (remove two, large, top mounting screws and rotate entire microwave down and off the wall mount). Should be some wood spacers between top of device and bottom of cabinet. 3. Remove screws from sheet metal cover
... Read more. 4. Remove one screw holding blowers in place and rotate out of the way, in order to gain access to 2 of 5 screws that hold the magnetron in place. 5. Unplug magnetron and remove the 5 screws. 6. Drop in new magnetron and re-assemble microwave in reverse order (steps 5-3). 7. Two people restore micro to wall/cabinet. Replace wood spacers, re-install two, large mounting screws (finger-tight). Test device. Secure the two large screws.
Read less
Was this helpful?
Thank you for voting!
Would not heat and made a buzzing or popping sound
4 of 7 peoplefound this instruction helpful.
Thomas from NEWARK, DE
Easy
15 - 30 mins
Screw drivers
Unplug the microwave. Remove the Philips head and safety Torx head screws along the bottom of the sides and rear of the microwave which hold the black cover on. Lift the cover up at the rear and slide it backwards to disengage the tabs on the front top. Remove the cover. Discharge the capacitor by shorting the terminals to each other
... Read moreand then ground. Do this with a well insulated object and be aware there may be a pop when you do this. Keep hands, etc. on the insulated part of the object (screwdriver handle, etc). There's a lot of stored energy in that capacitor. I'd advise first checking the diode to make sure its not bad. Replace it if it is. The Magnatron is held in with a couple of screws on the top and sides. Unplug the connector and remove the screws. Remove the Magnatron. Installation is the reverse of removal.