Float – Part Number: 5303306080
No Longer Available
Float
★★★★★
★★★★★
(3)
Part #5303306080
If the bucket is full indicator on your dehumidifier is on, but the bucket is empty, or your dehumidifier is overflowing, you may have a problem with the float. This device is located near the bucket and moves up as the water level in the bucket rises. The float will trip the water level switch when the bucket is full. This is a safety device to prevent the unit from overflowing. When the switch is tripped, power to the compressor and fan motor circuits is disrupted until the bucket is emptied. Make sure that the float assembly can move or pivot freely so that it can trigger the level switch when the bucket is full. If the assembly is warped or damaged it should be replaced.
Damper,Compressor – Part Number: 4H00982E
$8.55
Special Order
Damper,Compressor
Part #4H00982E
Humidistat Control – Part Number: 5303296823
No Longer Available
Humidistat Control
Part #5303296823
This is a humidistat control for a dehumidifier. The humidistat on your dehumidifier responds to the humidity in the air to determine if the appliance should continue to dehumidify or shut off, based on the desired humidity level. This control needs to be replaced if the dehumidifier wont shut off when the desired humidity level is reached. This part is approximately 3.5 inches long and 1.5 inches wide. The part will be easy to replace, simply remove the front cover, remove the humidistat from the bracket, and remove the two push-on wire connectors. Reverse this process to reinstall the control. Be sure to disconnect power to the dehumidifier before completing this repair.
Thermistor Assembly – Part Number: EBG61107109
$48.45
In Stock
Red Indicator Light Lens – Part Number: 318250801
No Longer Available
Red Indicator Light Lens
Part #318250801
This indicator light lens protects bulbs in ranges, ovens, stoves, and humidifiers. The lens keeps the bulb from getting cracked, scratched, and damaged. It is 1 inch long and 1 inch wide. If your lens is defective or broken, or the bulb is easily getting damaged, replacing the lens can be a solution. Refer to the installation instructions provided by the manufacturer for further accurate guidance. Remember to unplug your appliance from the power source before starting this project and wear gloves to ensure your hands are protected.
Auto Shut Off Switch – Part Number: 5308016437
No Longer Available
Auto Shut Off Switch
Part #5308016437
The auto shut off switch is for dehumidifiers. If the water bucket is not attached properly the switch will ensure the compressor does not run. You may need to perform a continuity test on the switch to determine if the part has indeed failed since you cannot tell by looking at it. Make sure your dehumidifier is unplugged before you begin. Consider wearing gloves to protect your hands while performing this task. This is a genuine OEM part that comes straight from the manufacturer.
Thermistor Assembly – Part Number: EBG61107014
$46.34
In Stock
Thermistor Assembly
Part #EBG61107014
SCREW – Part Number: 5304455651
$25.23
Special Order
SCREW
Part #5304455651
Fan,Propeller – Part Number: MDG37708601
$143.88
In Stock
Fan,Propeller
★★★★★
★★★★★
(1)
Part #MDG37708601
This propeller fan is designed to maintain optimal airflow in air conditioning and heat pump systems, ensuring efficient heating and cooling performance. It circulates conditioned air evenly throughout the space, helping regulate temperature and improve comfort. Built from durable materials, the fan supports system longevity and energy efficiency. If you notice unusual noises, reduced airflow, or uneven cooling, replacing the fan can restore proper operation. Confirm compatibility with your unit before installation.
KNOB-CONTROL – Part Number: 5308016109
No Longer Available
KNOB-CONTROL
Part #5308016109
MOTOR ASSEMBLY,DC,INDOOR – Part Number: 4681A20172Q
$207.88
In Stock
MOTOR ASSEMBLY,DC,INDOOR
★★★★★
★★★★★
(2)
Part #4681A20172Q
This DC motor assembly is a genuine replacement component designed for the outdoor unit of select LG ductless and window air conditioners. It powers the fan responsible for circulating air over the condensing coil, a critical function that supports cooling efficiency and overall system performance. By converting electrical energy into mechanical motion, the motor helps maintain proper airflow and temperature regulation. If your air conditioner is not blowing cold air or fails to turn on, a faulty motor may be the cause. Installation should be performed with the power disconnected to ensure safety. This OEM part is engineered for a precise fit and reliable operation, but users should verify compatibility with their specific model before installation due to variations in size and design.
Fan,Propeller – Part Number: MDG37706501
$75.13
In Stock
Fan,Propeller
Part #MDG37706501
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
LG Mini Split Air Conditioner Error Code CH 46
23 of 31 people found this instruction helpful.
  • Malcolm from Mt Pleasant, SC
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Remove the main power disconnect. Remove the top cover and the fan-side side panel. Disconnect the thermister from the main circuit board located under top panel. Remove the two thermister sensors from the holders attached to suction piping. Install the new thermisters and reconnect the harness to the circuit board. Reinstall top cover an d side panel. Reinstall main power disconnect. Verify that error code has cleared. Operate the system normally.
Was this helpful?
Thank you for voting!
Unit would run continuously and not shut off
7 of 9 people found this instruction helpful.
  • Jonathan from New Oxford, PA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Removed the front cover and then the humidistat from the bracket. Two push on wire connectors and then reversed. Very straightforward and excellent part matching. Given the prices for new dehumidifiers it was great to breathe life back into this unit which does its job well. Thanks for the easy to use web site and fast fast service!
Was this helpful?
Thank you for voting!
The float turned up missing during a move to another city.
4 of 5 people found this instruction helpful.
  • Gregory from MARINETTE, WI
  • Very Easy
  • Less than 15 mins
The repair was just putting the float into the inside of the tank itself and then, inserting the two pins (left and right) into each slot so the float operates up and down freely.
Was this helpful?