EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details
✖

Find Parts

Parts Departments

Top Model Types

Top Brands

Repair Help

Expert Repair Videos

Keep typing for more specific results...

MA2003B (BKEGSE) LG Range - Overview

Enter a part description. DIY Heroes keep it simple, eg. "belt" or "pump".

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Time Delay Fuse – Part Number: 3B74133Q
$11.77
In Stock
Time Delay Fuse
★★★★★
★★★★★
(3)
Part #3B74133Q
The fuse-time delay may also be known as a line fuse or a microwave fuse, and it is a piece for your microwave. The function of this part is to shut off the microwave if there is a power surge, in order to protect your microwave from damage. You should consider having a service technician install this part as the high-voltage capacitors in a microwave can contain a very harmful electrical charge, even when the microwave is unplugged and has been inactive for some time. The tools that would be needed to complete this installation include a Phillips screwdriver, an insulated screwdriver, and a pair of pliers.
Microwave Screwtapping – Part Number: 1TTL0402818
$13.92
Special Order
Switch,Micro – Part Number: 3B73361E
$21.45
Special Order
Switch,Micro
Part #3B73361E
This is a micro switch, but you may also know it as a door switch and it is compatible with your microwave. The function of the micro switch is to communicate to the electronic control board of your appliance when the door is opened and closed. If this part is broken and needs replacing you will notice your timer activated but the food inside is not being heated. This part measures to be roughly 1.5 inches long by just over half an inch wide, and it is black in color. You will find the location of this part behind the front panel of your microwave.
Turntable Assembly – Part Number: 5889W2A014C
No Longer Available
Turntable Assembly
Part #5889W2A014C
Lamp,Incandescent – Part Number: 6912W3B002L
$21.45
In Stock
Cover,Resin – Part Number: 3052W2A021A
No Longer Available
Cover,Resin
Part #3052W2A021A
Screw,Taptite – Part Number: 1SBF0402418
$13.92
Special Order
Screw,Taptite
Part #1SBF0402418
Screw,Tapping – Part Number: 1TTL0402418
$11.77
In Stock
Screw,Tapping
Part #1TTL0402418
Lamp,Incandescent – Part Number: 6912W3B002G
No Longer Available
Lamp,Incandescent
Part #6912W3B002G
Micro Switch – Part Number: 3B73362E
$21.45
Special Order
Micro Switch
Part #3B73362E
Wire Holder – Part Number: 4B72944B
$13.92
Special Order
Wire Holder
Part #4B72944B
Screw,Tapping – Part Number: 1TPL0402418
$29.47
Special Order
Screw,Tapping
Part #1TPL0402418

Common Symptoms of the MA2003B

How this model fails, and the parts that fix it.

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Light bulb went out
1 person found this instruction helpful.
  • Andrea from Fanning Springs, FL
  • Very Easy
  • 15 - 30 mins
  • Screw drivers
Remove screws, take microwave cover off. Pull light assembly and unplug bulb. Replace with new bulb and snap back in place. Screw cover on and your done.
Was this helpful?
Thank you for voting!
Microwave operated but did not heat
3 of 10 people found this instruction helpful.
  • Donald from Oak Ridge, TN
  • Easy
  • 1- 2 hours
  • Screw drivers
Initial failure of over range microwave Aug 3rd. Control Panel worked but no heat. Took to local LG authoriaed local repair place. They fixed it quickly and we re-installed it. Worked fine for 2 months then had similar failure again. Agaim took to same authorized repairer. They kept unit for 3 months but finally concluded theu could not fix it and suggested we contact LG for a partial refund. When they tested the unit during re-assembly in my presence, there was a blue flash and the fuse blew. Since we had built a custom tile mural back splash around this unit, I brought it home, ordered a number of time delay fuses new capacitor and two new high voltage diodes. However, using my Fluke DMM, I checked the existing capacitor and high voltage diode and they checked OK so I just replaced the time delay fuse. The high voltage transformer leads had 2 possible ways to connect to capacitor and diode. Tried one way, plugged unit in and turned it on, and immediatly blew the fuse. Replaced the fuse and reversed the high voltage transformer connections,amd turned unit pn, and it worked perfectly. Since we had experienced several power failures during the time of the original failure, the repairer concluded that power spikes might be at fault, so I also purchased a TrippLite ISOBAR4ULTRA 3300 Joule surge protector between wall outlet and microwave, and re-installed over range. It has worked perfectly since.