The condenser fan blade fits onto the air conditioner motor shaft. The fan blade helps circulate air over the condenser to cool the refrigerant before it enters in to the evaporator. This part is beige in color, made of plastic and measures approximately14 1/2” in diameter. This is a genuine OEM part. Please remember to disconnect the power to the air conditioner before starting the repair.
This spring clamp is designed for your room air conditioner. This clamp holds the fan blade on the motor shaft so it can rotate during operation. If your fan blade is wobbling on the motor shaft, you may need to replace it. The part is made of metal and is approximately 3/4-inch in diameter. This is an OEM part sourced directly from the m...Read moreanufacturer. This spring clamp is sold individually. Before you begin this repair, make sure your air conditioner is disconnected from the power source. To complete this repair, you will likely need to remove the air conditioning unit from the wall.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Broken fan axial blade
8 of 13 peoplefound this instruction helpful.
John from HARLINGEN, TX
Easy
30 - 60 mins
Pliers, Screw drivers
Unscrewed the unit from the exterior case pulled out the unit unscrewed the 4 screw that hold the fan shroud carefully unscrewed the coil pulled back unclipped the axial fan clip gentlyhit with rubber mallet replacement of new fan replaced clip 15 minutes best investment of 20 bucks as apposed to 400 $
Was this helpful?
Thank you for voting!
compressor staying on, even in OFF mode: failed compressor relay on Printed Circuit Board #EBR895407
2 of 3 peoplefound this instruction helpful.
Philip from NEW MARKET, VA
A Bit Difficult
15 - 30 mins
Screw drivers
PC Board #EBR895407 No Longer Available, replaced with #EBR7773051 - mirror image board, but wires long enough and connections same. Unit unplugged: slide filter up and out. Remove two phillips screws behind where top of filter was to remove grill (easier done with magnetic screw driver). Remove two phillips screws, one each side, at
... Read more base of cabinet. Slide assembly out of cabinet 6-8". Remove phillips screw(s) on metal control panel housing. With needle nose, rock (2) main female spade connectors left/right until off (easier done with PC board still secured). Remove phillips screw holding plastic base of PC board. Viewing new board control connectors will simplify disconnecting the (3) control plugs. A small straight blade screwdriver can help.
Read less
Was this helpful?
Thank you for voting!
window a/x unit fan broke
6 of 22 peoplefound this instruction helpful.
margaret from CARRIERE, MS
Really Easy
15 - 30 mins
Pliers
took apart the fan housing and replaced the fan saving me hundreds of dollars from buying a new unit