Models
>
LW1212HR
LW1212HR (AWYAHDP) LG Air Conditioner - Overview
Sections of the LW1212HR
[Viewing 1 of 1]Keep searches simple, eg. "belt" or "pump".
Fan Assembly,Axial
PartSelect #: PS3528606
Manufacturer #: 5900AR1173A
The fan assembly or condenser fan blade fits on the motor shaft and circulates air over the condenser. This cools the refrigerant before it enters the evaporator. If the fan assembly in your room air ...
No Longer Available
Room Air Conditioner Installation Kit
PartSelect #: PS7784777
Manufacturer #: 3127A20074Y
The installation kit contains the hardware you need to install the room air conditioner.
$48.05
On Order
CLAMP,SPRING
PartSelect #: PS16224004
Manufacturer #: MBU64446301
The fan blade clamp, also known as a clamp spring, are for air conditioners. The clamp supports the fan blade on the motor shaft. When the motor is running, it signals the shaft to turn and rotate, bu...
$6.37
In Stock
Questions And Answers for LW1212HR
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Sort by:
- < Prev
- 1
- Next >
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Mike
July 27, 2023
Can these ac window units be recharged with freon? Mine has quit cooling
For model number LW1212HR
Hello Mike, thank you for your query. According to our research, a window air conditioner can be recharged. The correct refrigerant will be needed, along with HVAC gauges. Before that, we would recommend checking the thermistor, part number PS3528976, to fix the issue. It monitors temperatures and communicates the temperature to the control board. If it is faulty, the air conditioner may not cool. We hope this solves your problem!
Was this helpful?
Thank you for voting!
Related Parts:
- < Prev
- 1
- Next >
Common Symptoms of the LW1212HR
[Viewing 1 of 1]Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
fan had stripped out and was replacing.
very tight working situations. made a mistake with a delicate piece of the fan and broke it and that rendered the part unuseful. Since I broke it I considered it to be my fault and just threw it away. Ordered another from another company hoping that just maybe it would be more durable. It arrived in only 4 days. Yours took well over
... Read more
a week to arrive. Thanks for asking for my experience.
Read less
Parts Used:
-
Douglas from ENGLEWOOD, TN
-
Difficulty Level:Very Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Pliers, Screw drivers, Socket set
1 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!