EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details
✖

Find Parts

Parts Departments

Top Model Types

Top Brands

Repair Help

Expert Repair Videos

Keep typing for more specific results...

LMH1017CVW (01) LG Microwave - Overview

Diagrams for LMH1017CVW

See every part. Know exactly what you need.

Enter a part description. DIY Heroes keep it simple, eg. "belt" or "pump".

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Microwave Thermostat – Part Number: 6930W1A003X
$31.85
In Stock
Microwave Thermostat
★★★★★
★★★★★
(12)
Part #6930W1A003X
This thermal safety thermostat helps protect the appliance from overheating by interrupting an electrical circuit when temperatures rise above its cutoff point. It senses heat at its mounting location and limits operation to help protect nearby wiring and components. A failed thermostat may prevent heating or leave the appliance unable to operate. Replacing a faulty unit helps restore the temperature protection needed for normal use. The thermostat works as a safety limit rather than a control for selecting everyday cooking temperatures. This is an OEM part sourced directly from the manufacturer.
Micro Switch – Part Number: 6600W1K001D
$25.78
In Stock
Micro Switch
★★★★★
★★★★★
(27)
Part #6600W1K001D
This microwave door interlock switch responds to the door latch, helping prevent cooking operation while the door is open. Its small actuator changes the electrical contact when the door opens or closes. A worn or damaged switch may prevent the microwave from starting even when the door is fully shut. Replacing a faulty switch helps restore proper door detection within the safety interlock system. Internal microwave components can retain a dangerous electrical charge after unplugging, so disconnecting power alone does not make them safe to handle. This is an OEM part sourced directly from the manufacturer.
Time Delay Fuse – Part Number: 3B74133Q
$11.77
In Stock
Time Delay Fuse
★★★★★
★★★★★
(3)
Part #3B74133Q
Electrical overload protection comes from this microwave time delay fuse, rated at 20 amps and 250 volts. It tolerates brief startup current while opening the circuit during a sustained overload or short circuit. A blown main fuse may leave the microwave without power or prevent it from starting. The fuse cannot be reset and requires replacement once it opens. Internal microwave components can retain a dangerous electrical charge after unplugging, so disconnecting the power cord alone does not make internal handling safe. This is an OEM part sourced directly from the manufacturer.
Microwave Locker – Part Number: 4026W2A019A
$21.95
In Stock
Microwave Locker
★★★★★
★★★★★
(9)
Part #4026W2A019A
Secure door closure relies on this black plastic microwave door latch hook. Installed inside the door assembly, it engages the latch openings and operates the safety interlock switches when the door closes. A cracked hook or damaged latch may prevent the door from staying shut or keep the microwave from starting. Replacing a damaged latch helps restore proper mechanical engagement and door operation. The hook moves with the door release mechanism, allowing the door to open when released and latch again when closed. This is an OEM part sourced directly from the manufacturer.
FOOT – Part Number: 4778W1N001B
$31.85
In Stock
FOOT
★★★★★
★★★★★
(1)
Part #4778W1N001B
This range leveling leg supports the appliance and lets you adjust the height of one corner for a steady, level cooking surface. Its threaded post screws into the base and turns to raise or lower the range on uneven flooring. A bent leg, damaged threads, or a missing foot may cause the stove to rock or sit unevenly. Replacing a damaged leg helps restore stable support and align the range with nearby countertops. A level surface also helps keep oil and batter from pooling to one side. This is an OEM part sourced directly from the manufacturer.
Magnetron – Part Number: 6324W1A001L
$130.68
In Stock
Magnetron
★★★★★
★★★★★
(8)
Part #6324W1A001L
Microwave energy for heating food is generated by this magnetron, which converts electrical power from the high voltage circuit into cooking energy. A failed magnetron may leave the appliance running without heating, even while the turntable, display, and fan continue to operate. Replacing a faulty unit helps restore the energy needed to warm and cook food. Internal microwave components can retain a dangerous electrical charge after the appliance is unplugged, so disconnecting power alone does not make the internal circuitry safe to handle. This is an OEM part sourced directly from the manufacturer.
Microwave Motor Ac Synchronous – Part Number: 6549W1S013H
$48.35
In Stock
Microwave Motor Ac Synchronous
★★★★★
★★★★★
(5)
Part #6549W1S013H
If the turntable on your microwave does not rotate, or you can hear a grinding noise, the problem may be with the motor. The motor is typically located below the floor of the oven, and is accessed through the bottom. The motor is normally held in place with a retaining screw and will have two wires attached to it as well. If the motor is making a grinding noise it will need to be replaced. If the motor does not turn, you can check for voltage or continuity with a multi-meter. Make sure the power is disconnected from your microwave before beginning this repair.
Microwave Screwtapping – Part Number: 1TTL0402818
$16.45
On Order
Diode (Cable, Assembly) – Part Number: 6851W1A002E
$17.15
In Stock
Diode (Cable, Assembly)
★★★★★
★★★★★
(1)
Part #6851W1A002E
Current flows in one direction through this microwave high voltage diode and cable assembly, which works with the capacitor and transformer to supply the magnetron. This electrical process supports the microwave energy used to heat food. A failed diode may cause a loss of heating or unusual humming while the appliance runs. Replacing a faulty assembly helps restore normal high voltage circuit operation. Internal microwave components can retain a dangerous electrical charge after unplugging, so disconnecting power alone does not make them safe to handle. This is an OEM part sourced directly from the manufacturer.
TURNTABLE ASSEMBLY – Part Number: 5889W2A015A
No Longer Available
Assembly Kit – Part Number: 3861W2A006A
No Longer Available
Assembly Kit
Part #3861W2A006A

Common Symptoms of the LMH1017CVW

How this model fails, and the parts that fix it.

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Broken door micro switch. (unit does not start heating)
37 of 68 people found this instruction helpful.
  • JAMES from BILLINGS, MT
  • Very Easy
  • 30 - 60 mins
  • Screw drivers
Unplug the unit before servicing. Need phillips screwdriver. Open door. Use step ladder to access and remove 2 small screws from top of the room air diffuser at top of unit. Slide diffuser slightly to the left to align the diffuser's plastic tab on the left side to rotate toward you. (The wires for the front control panel are at the far l eft side of this difuser, but difuser is slotted for easy removal). Once the difuser is removed you will see 1 screw at the top that secures the pannel cover on the left side of the unit. Remove screw and slide this panel slightly up and out. This exposes the plastic frame that holds the upper and lower door switches. To locate the door switches and observe how they work, close and open the door and watch the door (bayonets) open and close the micro switches. Do the (red) buttons on top of the switches move up and down when the door bayonets push and release? If the buttons do not "pop" up when opened the switch is defective. The switch frame is secured with 2 screws. Remove screws and rotate the unit out for easy access to the micro switch(s). The internal (spring?) on my unit that is suposed to allow the red (visible) button on top of the switch to "pop" up when the door is opened was broken. Carefully pry the switch outward while being careful to lift the plastic holder-piece that holds the switch in place. Be careful, there is a small pin on the frame, so rotate the switch OUT toward you while lifting (carefully) the plastic holder-piece (you will see it on top of the switch). You can use an ohm meter to test the continuity of the switches. But if the buttons don't "pop" they are defective. Replace switch and reassemble.
Was this helpful?
Thank you for voting!
One of the switches in a component that door activates when shut.
9 of 11 people found this instruction helpful.
  • Jimmy from OZARK, MO
  • Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
I replaced the whole component with all three switches in it even though only one switch was bad . Taking out one switch out of the holder unit would probably have damaged the unit that was holding the switches. Easy install and it works great again .
Was this helpful?
Thank you for voting!
Door sensor switch went bad. Microwave would not operate.
15 of 29 people found this instruction helpful.
  • Randall from ARCADIA, CA
  • A Bit Difficult
  • 1- 2 hours
  • Pliers, Screw drivers
Watched a couple of repair videos on Youtube by searching for the model number. Found out what to do in order not to get shocked by the powerful capacitor.
Ordered the two switches (To be sure, I could have ordered a third switch as suggested in the videos.)
Bought a tamper-proof star bit to get the cover off. Followed the dir ections to replace the switches. - I broke the harness and had to use some super glue, but it's all good. I should have removed the harness instead of trying to get a switch out while it was still in place.
It's all back together, and the wife is happy!!
Was this helpful?
Thank you for voting!