Time Delay Fuse – Part Number: 3B74133Q
$11.77
In Stock
Time Delay Fuse
★★★★★
★★★★★
(3)
Part #3B74133Q
Electrical overload protection comes from this microwave time delay fuse, rated at 20 amps and 250 volts. It tolerates brief startup current while opening the circuit during a sustained overload or short circuit. A blown main fuse may leave the microwave without power or prevent it from starting. The fuse cannot be reset and requires replacement once it opens. Internal microwave components can retain a dangerous electrical charge after unplugging, so disconnecting the power cord alone does not make internal handling safe. This is an OEM part sourced directly from the manufacturer.
Insulator Cover – Part Number: MCK69074904
$21.95
In Stock
Insulator Cover
Part #MCK69074904
Sparking in a microwave is associated with the waveguide insulator cover. It insulates the waveguide area, and this OEM part is for microwave applications.
TRAY,GLASS – Part Number: MJS63771901
$39.55
On Order
Microwave Thermostat – Part Number: 6930W1A004N
$16.45
Special Order
Microwave Thermostat
Part #6930W1A004N
FOOT ASSEMBLY – Part Number: ADU73009001
$16.45
In Stock
FOOT ASSEMBLY
Part #ADU73009001
Screw,Customized – Part Number: 4000W4A003A
$16.45
In Stock
Screw,Customized
Part #4000W4A003A
MOTOR, AC SYNCHRONOUS – Part Number: 6549W1S011E
$33.69
In Stock
Thermostat – Part Number: 6930W1A003A
$25.78
Special Order
Screw,Taptite – Part Number: 1SBF0402418
$16.45
Special Order
Screw,Taptite
Part #1SBF0402418
TURNTABLE ASSEMBLY – Part Number: AJS73129202
$35.39
In Stock
TURNTABLE ASSEMBLY
Part #AJS73129202
LOCKER – Part Number: MFG63839001
$16.45
In Stock
LOCKER
Part #MFG63839001
THERMOSTAT – Part Number: 6930W1A004X
$16.45
Special Order

Questions And Answers for LMC0975ST

Ask our experts a question about this model and we'll get back to you as soon as possible!

Sort by:
  • 1
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Lori - For model number LMC0975ST
January 22, 2025
Where is the oven light bulb located in this microwave? Ours has been out for awhile and I can't find it to replace it.
Chris Boyle Profile
Hi Lori, Thank you for your question. The part number for the lamp assembly is PS12078343. It is found at the top of the interior of the microwave towards the front. We hope this helps!
$44.23
Special Order
HOLDER ASSEMBLY,LAMP
Was this helpful?
Thank you for voting!
  • 1

Common Symptoms of the LMC0975ST

How this model fails, and the parts that fix it.

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Sparks from an old wave guide that needed to be replaced
5 of 6 people found this instruction helpful.
  • Ellen from REDDING, CA
  • Easy
  • 15 - 30 mins
Put microwave on its side as my hands weren’t ready enough to hold it up while trying to push it in.
Put board on the door to hold it open.
Gently pushed the wave guide back as far as it would go. Then, I carefully pushed the front tabs in place. No bending. I had practiced on the old one first. Broke the 2 old tabs by pushing back to hard so you need to be careful.
Was this helpful?
Thank you for voting!
Cracked glass tray replaced
1 of 2 people found this instruction helpful.
  • Joseph from PARKER, CO
  • Very Easy
  • Less than 15 mins
Open the micro door, removed glass plate and installed the replacement
Was this helpful?
Thank you for voting!
Microwave operated but did not heat
3 of 10 people found this instruction helpful.
  • Donald from Oak Ridge, TN
  • Easy
  • 1- 2 hours
  • Screw drivers
Initial failure of over range microwave Aug 3rd. Control Panel worked but no heat. Took to local LG authoriaed local repair place. They fixed it quickly and we re-installed it. Worked fine for 2 months then had similar failure again. Agaim took to same authorized repairer. They kept unit for 3 months but finally concluded theu could not fix it and suggested we contact LG for a partial refund. When they tested the unit during re-assembly in my presence, there was a blue flash and the fuse blew. Since we had built a custom tile mural back splash around this unit, I brought it home, ordered a number of time delay fuses new capacitor and two new high voltage diodes. However, using my Fluke DMM, I checked the existing capacitor and high voltage diode and they checked OK so I just replaced the time delay fuse. The high voltage transformer leads had 2 possible ways to connect to capacitor and diode. Tried one way, plugged unit in and turned it on, and immediatly blew the fuse. Replaced the fuse and reversed the high voltage transformer connections,amd turned unit pn, and it worked perfectly. Since we had experienced several power failures during the time of the original failure, the repairer concluded that power spikes might be at fault, so I also purchased a TrippLite ISOBAR4ULTRA 3300 Joule surge protector between wall outlet and microwave, and re-installed over range. It has worked perfectly since.
Was this helpful?
Thank you for voting!