EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details

Find Parts

Parts Departments

Top Model Types

Top Brands

Repair Help

Expert Repair Videos

Keep typing for more specific results...

LMC0975ASZ (CSSEAMZ) LG Range - Overview

Diagrams for LMC0975ASZ

See every part. Know exactly what you need.

Enter a part description. DIY Heroes keep it simple, eg. "belt" or "pump".

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Time Delay Fuse – Part Number: 3B74133Q
$11.77
On Order
Time Delay Fuse
★★★★★
★★★★★
(3)
Part #3B74133Q
The fuse-time delay may also be known as a line fuse or a microwave fuse, and it is a piece for your microwave. The function of this part is to shut off the microwave if there is a power surge, in order to protect your microwave from damage. You should consider having a service technician install this part as the high-voltage capacitors in a microwave can contain a very harmful electrical charge, even when the microwave is unplugged and has been inactive for some time. The tools that would be needed to complete this installation include a Phillips screwdriver, an insulated screwdriver, and a pair of pliers.
Insulator Cover – Part Number: MCK69074904
$13.92
In Stock
Insulator Cover
Part #MCK69074904
This mica plate, also known as an insulator cover or a waveguide cover, protects the opening where microwaves enter the cooking cavity from the magnetron. By covering it, the plate ensures the even distribution of microwaves while also preventing food particles and vapor from causing damage to the internal components. If this cover becomes damaged, you may notice sparks or arcing inside the microwave during use. This replacement part is sourced directly from its original manufacturer.
TRAY,GLASS – Part Number: MJS63771901
$32.63
On Order
Microwave Thermostat – Part Number: 6930W1A004N
$13.92
Special Order
Microwave Thermostat
Part #6930W1A004N
FOOT ASSEMBLY – Part Number: ADU73009001
$13.92
In Stock
FOOT ASSEMBLY
Part #ADU73009001
Screw,Customized – Part Number: 4000W4A003A
$13.92
Special Order
Screw,Customized
Part #4000W4A003A
MOTOR, AC SYNCHRONOUS – Part Number: 6549W1S011E
$33.69
In Stock
Thermostat – Part Number: 6930W1A003A
$21.45
Special Order
Screw,Taptite – Part Number: 1SBF0402418
$13.92
Special Order
Screw,Taptite
Part #1SBF0402418
TURNTABLE ASSEMBLY – Part Number: AJS73129202
$29.47
On Order
TURNTABLE ASSEMBLY
Part #AJS73129202
LOCKER – Part Number: MFG63839001
$13.92
In Stock
LOCKER
Part #MFG63839001
MAGNETRON – Part Number: EAS61382907
$130.18
On Order
MAGNETRON
Part #EAS61382907

Common Symptoms of the LMC0975ASZ

How this model fails, and the parts that fix it.

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Sparks from an old wave guide that needed to be replaced
5 of 6 people found this instruction helpful.
  • Ellen from REDDING, CA
  • Easy
  • 15 - 30 mins
Put microwave on its side as my hands weren’t ready enough to hold it up while trying to push it in.
Put board on the door to hold it open.
Gently pushed the wave guide back as far as it would go. Then, I carefully pushed the front tabs in place. No bending. I had practiced on the old one first. Broke the 2 old tabs by pushing back to hard so you need to be careful.
Was this helpful?
Thank you for voting!
Cracked glass tray replaced
1 of 2 people found this instruction helpful.
  • Joseph from PARKER, CO
  • Very Easy
  • Less than 15 mins
Open the micro door, removed glass plate and installed the replacement
Was this helpful?
Thank you for voting!
Microwave operated but did not heat
3 of 10 people found this instruction helpful.
  • Donald from Oak Ridge, TN
  • Easy
  • 1- 2 hours
  • Screw drivers
Initial failure of over range microwave Aug 3rd. Control Panel worked but no heat. Took to local LG authoriaed local repair place. They fixed it quickly and we re-installed it. Worked fine for 2 months then had similar failure again. Agaim took to same authorized repairer. They kept unit for 3 months but finally concluded theu could not fix it and suggested we contact LG for a partial refund. When they tested the unit during re-assembly in my presence, there was a blue flash and the fuse blew. Since we had built a custom tile mural back splash around this unit, I brought it home, ordered a number of time delay fuses new capacitor and two new high voltage diodes. However, using my Fluke DMM, I checked the existing capacitor and high voltage diode and they checked OK so I just replaced the time delay fuse. The high voltage transformer leads had 2 possible ways to connect to capacitor and diode. Tried one way, plugged unit in and turned it on, and immediatly blew the fuse. Replaced the fuse and reversed the high voltage transformer connections,amd turned unit pn, and it worked perfectly. Since we had experienced several power failures during the time of the original failure, the repairer concluded that power spikes might be at fault, so I also purchased a TrippLite ISOBAR4ULTRA 3300 Joule surge protector between wall outlet and microwave, and re-installed over range. It has worked perfectly since.
Was this helpful?
Thank you for voting!