Restore visibility in the microwave cavity or over the cooktop with this replacement incandescent lamp. The 30 watt bulb uses a screw base to connect to the light socket and provides illumination when the appliance lighting is activated. A burned out filament may leave the area dark while the microwave continues operating normally. Replac...Read moreing a failed bulb restores light for checking food or viewing the cooking surface below. Disconnect power, allow the lamp to cool, and follow the appliance instructions for access to the bulb. This is an OEM part sourced directly from the manufacturer.
This thermal safety thermostat helps protect the appliance from overheating by interrupting an electrical circuit when temperatures rise above its cutoff point. It senses heat at its mounting location and limits operation to help protect nearby wiring and components. A failed thermostat may prevent heating or leave the appliance unable to...Read more operate. Replacing a faulty unit helps restore the temperature protection needed for normal use. The thermostat works as a safety limit rather than a control for selecting everyday cooking temperatures. This is an OEM part sourced directly from the manufacturer.
This microwave door interlock switch responds to the door latch, helping prevent cooking operation while the door is open. Its small actuator changes the electrical contact when the door opens or closes. A worn or damaged switch may prevent the microwave from starting even when the door is fully shut. Replacing a faulty switch helps resto...Read morere proper door detection within the safety interlock system. Internal microwave components can retain a dangerous electrical charge after unplugging, so disconnecting power alone does not make them safe to handle. This is an OEM part sourced directly from the manufacturer.
This bracket holds the metal or plastic flapper that closes off the exhaust duct when the fan is not running and opens when the fan turns on. If the exhaust fan on your microwave does not appear to be working, the problem may be with the damper assembly. If the damper does not open and close easily, check for any damage to the bracket, an...Read mored replace if it is damaged or faulty. This genuine OEM exhaust damper measures approximately 12 inches long by 5 inches wide.
Exhaust air passes through this microwave vent damper when the ventilation fan runs. The metal flap opens with outgoing airflow to let steam and cooking odours enter the exhaust duct, then closes when airflow stops to help limit outside drafts. A bent, warped, or stuck flap may restrict ventilation or allow air to flow back into the kitch...Read moreen. Replacing a damaged damper helps restore free flap movement and proper exhaust operation, providing a movable barrier at the duct opening between fan uses. This is an OEM part sourced directly from the manufacturer.
Secure door closure relies on this black plastic microwave door latch hook. Installed inside the door assembly, it engages the latch openings and operates the safety interlock switches when the door closes. A cracked hook or damaged latch may prevent the door from staying shut or keep the microwave from starting. Replacing a damaged latch...Read more helps restore proper mechanical engagement and door operation. The hook moves with the door release mechanism, allowing the door to open when released and latch again when closed. This is an OEM part sourced directly from the manufacturer.
Microwave energy for heating food is generated by this magnetron, which converts electrical power from the high voltage circuit into cooking energy. A failed magnetron may leave the appliance running without heating, even while the turntable, display, and fan continue to operate. Replacing a faulty unit helps restore the energy needed to ...Read morewarm and cook food. Internal microwave components can retain a dangerous electrical charge after the appliance is unplugged, so disconnecting power alone does not make the internal circuitry safe to handle. This is an OEM part sourced directly from the manufacturer.
Current flows in one direction through this microwave high voltage diode and cable assembly, which works with the capacitor and transformer to supply the magnetron. This electrical process supports the microwave energy used to heat food. A failed diode may cause a loss of heating or unusual humming while the appliance runs. Replacing a fa...Read moreulty assembly helps restore normal high voltage circuit operation. Internal microwave components can retain a dangerous electrical charge after unplugging, so disconnecting power alone does not make them safe to handle. This is an OEM part sourced directly from the manufacturer.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Broken door micro switch. (unit does not start heating)
37 of 68 peoplefound this instruction helpful.
JAMES from BILLINGS, MT
Very Easy
30 - 60 mins
Screw drivers
Unplug the unit before servicing. Need phillips screwdriver. Open door. Use step ladder to access and remove 2 small screws from top of the room air diffuser at top of unit. Slide diffuser slightly to the left to align the diffuser's plastic tab on the left side to rotate toward you. (The wires for the front control panel are at the far l
... Read moreeft side of this difuser, but difuser is slotted for easy removal). Once the difuser is removed you will see 1 screw at the top that secures the pannel cover on the left side of the unit. Remove screw and slide this panel slightly up and out. This exposes the plastic frame that holds the upper and lower door switches. To locate the door switches and observe how they work, close and open the door and watch the door (bayonets) open and close the micro switches. Do the (red) buttons on top of the switches move up and down when the door bayonets push and release? If the buttons do not "pop" up when opened the switch is defective. The switch frame is secured with 2 screws. Remove screws and rotate the unit out for easy access to the micro switch(s). The internal (spring?) on my unit that is suposed to allow the red (visible) button on top of the switch to "pop" up when the door is opened was broken. Carefully pry the switch outward while being careful to lift the plastic holder-piece that holds the switch in place. Be careful, there is a small pin on the frame, so rotate the switch OUT toward you while lifting (carefully) the plastic holder-piece (you will see it on top of the switch). You can use an ohm meter to test the continuity of the switches. But if the buttons don't "pop" they are defective. Replace switch and reassemble.
Read less
Was this helpful?
Thank you for voting!
The major plastic frame was broken at the screw hole support. I was sent the wrong part and found out the part I needed was no longer made and would have to buy a new door for $150.
10 of 11 peoplefound this instruction helpful.
Kyle from LANCASTER, CA
Really Easy
30 - 60 mins
Screw drivers
The wrong part was under $20. When I found out I had to replace the whole door for $150. I decided DYI was the way to go. I used JB weld and the door looks and works like a charm. Give plenty of time to cure all water needs to be cured out if exposed to microwaves. No problems so far.
Was this helpful?
Thank you for voting!
Door sensor switch went bad. Microwave would not operate.
15 of 29 peoplefound this instruction helpful.
Randall from ARCADIA, CA
A Bit Difficult
1- 2 hours
Pliers, Screw drivers
Watched a couple of repair videos on Youtube by searching for the model number. Found out what to do in order not to get shocked by the powerful capacitor. Ordered the two switches (To be sure, I could have ordered a third switch as suggested in the videos.) Bought a tamper-proof star bit to get the cover off. Followed the dir
... Read moreections to replace the switches. - I broke the harness and had to use some super glue, but it's all good. I should have removed the harness instead of trying to get a switch out while it was still in place. It's all back together, and the wife is happy!!