JEM31WYC002 General Electric Microwave - Overview

Diagrams for JEM31WYC002

See every part. Know exactly what you need.

Enter a part description. DIY Heroes keep it simple, eg. "belt" or "pump".

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Primary Door Interlock Switch – Part Number: WB24X10047
$54.07
In Stock
Primary Door Interlock Switch
★★★★★
★★★★★
(20)
Part #WB24X10047
This interlock switch is located in the door latch.
Ceramic Fuse - 15 Amp – Part Number: WB27X7
$23.19
In Stock
Ceramic Fuse - 15 Amp
Part #WB27X7
Steam Sensor – Part Number: WB24X799
$150.57
In Stock
Steam Sensor
★★★★★
★★★★★
(1)
Part #WB24X799
Used in compatible GE microwaves, this steam sensor detects cooking vapors so the appliance can respond during sensor cooking. Poor sensor-cook results may also come from the control or cooking conditions, so check the model and diagnose the circuit before replacing it. Microwave internal service should be performed by a qualified technician.
SMARTBOARD – Part Number: WB27X10076
No Longer Available
SMARTBOARD
Part #WB27X10076
Assembly WIRE HARNESS-S – Part Number: WB18X10030
$37.91
Special Order
Assembly WIRE HARNESS-S
Part #WB18X10030
USE GEH WB6X321 – Part Number: WB06X0321
No Longer Available
USE GEH WB6X321
Part #WB06X0321
BRACKET-HVC – Part Number: WB6X377
$8.55
Special Order
BRACKET-HVC
Part #WB6X377
SUPT HINGE – Part Number: WB1X1497
$10.70
Special Order
SUPT HINGE
Part #WB1X1497
THERMOSTAT – Part Number: WB21M261
No Longer Available
THERMOSTAT
Part #WB21M261
MAGNETRON TUBE – Part Number: WB27M806
No Longer Available
MAGNETRON TUBE
Part #WB27M806
DISCONTINUED – Part Number: WB2X4606
No Longer Available
DISCONTINUED
Part #WB2X4606

Common Symptoms of the JEM31WYC002

How this model fails, and the parts that fix it.

Watch our pros, then fix it yourself.

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Microwave would turn on and count down, but not heating and not rotate turntable. Pressing door up would occasionally start heat.
40 of 67 people found this instruction helpful.
  • Michael from Ridgefield, CT
  • Really Easy
  • Less than 15 mins
  • Screw drivers
First I disconnected the power and opened the door. Then I removed the top screws holding the top vent louvers, then removed the screw at the top of the touch pad. The touch pad removes by sliding up slightly then tilting top out. I unscrewed two screws holding the door latch assembly. Press the tab to remove and replace switch. Reco nnect wires, reseat latch mount by placing top bracket tab in place first, allign and secure with screws. Reseat touch pad by placing bottom tabs in first, tilt forward and press up to seat top tabs, secure with top screw. Secure vent louver screws, plug in and watch your microwave work again.
Was this helpful?
Thank you for voting!
Microwave runs with the door open
37 of 58 people found this instruction helpful.
  • Thomas from Andover, NJ
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
Remove microwave outer cover. Turn on side & locate the upper & lower door switches. Better to replace in pairs even if one is ok. Remove the wire harness to each switch. Then replace switch and re connect the wire harness. Re attach outer cover
and test to see if that solved the problem. If so then well done!!
Was this helpful?
Thank you for voting!
Everything seemed to work with the controls, but when you pressed start the light would come on and nothing else. The turntable and heating system would not function.
25 of 43 people found this instruction helpful.
  • Keith from Bowling Green, KY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I unplugged it, removed the outer shell with torque bits and a screwdriver, drained the main capacitor, and began debugging the circuit with my fluke multimeter, found the bad primary interlock, googled the part number, ordered the part, received it in 2 days, replaced the interlock in about 2 minutes, and put the cover back on. Fixed. Saved me about $200 over buying a new unit and was grateful for partselect's great service.

-Keith Packard
Was this helpful?
Thank you for voting!