Lights inside refrigerator not working
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
Parts Used:
Refrigerator Door Switch
  • Clint from Rayville, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
136 of 250 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not exit defrost mode (continual defrost)
Unplug the refrigerator. Remove face plate located in the upper back of the refrigerator compartment. Remove face place bracket on the right using nut driver. Removing these screws also frees the metal case enclosing the Defrost Timer. Pull the case away from the back of the refrigerator exposing the Defrost timer. Remove the electrical plug from the Defrost Timer. Then remove the Defrost Timer from the case by removing the two screws securing it. Reverse the procedure to install the new Defrost Timer.
Parts Used:
Defrost Timer - 120V 60Hz
  • Leon from Chaparral, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
44 of 56 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Switch broke
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
Parts Used:
Refrigerator Door Switch
  • James Richard from St. Cloud, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
48 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The light switch on the refridgerator broke - no light.
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.

The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.

I'm very pleased!
Parts Used:
Refrigerator Door Switch
  • David from Albany, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
36 of 56 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator fresh food side warm, freezer frosted over
First did the easy part, removed and replaced the defrost timer. Didn't correct the problem.

Then got into the defrost heaters. Big job, because the factory didn't provide for repairs. Had to remove the ice maker because there was one screw holding on the cover panel behind it. The factory installed defrost heaters were run behind the freezer coils so I had to cut them out. Then I had to bend the light aluminum sides with heavy pliers to slip the burned out defrost heaters out and replace them with the new defrost heaters. Didn't use the defrost timer, because I was taking it one step at a time.

Now the refrigerator fresh food side maintains 39 degrees and runs 1/10 the time it was running. My wife says it's better than new! Saved $ 2,400 (the replacement she had picked out).
Parts Used:
Refrigerator Defrost Heater Kit
  • Ernest from Shelby, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
21 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was freezing up and not cooling!
Well first I noticed the back of the freezer compartment freezing up and the ice not freezing. I moved all the contents of the freezer to another freezer. I waited and noticed even when pluged in and everything defrosted the fan didn't kick on on the condensing unit! After a few minutes it did kick on and I took a guess that the defrost timer was probally ok without checking it. I took eight screws out of the back plate and noticed the defrosting tube on the lower part of the coil was broke in half. I knew I had found the problem. It took maybe 10 minutes to remove and about 10 minutes to order the part. Three days later it was at my door. I took my time installing it which only took maybe 30 minutes. It took longer for me to wipe everything down and clean the inside of both compartments than it did to insall the part. Pluged it in and fired it up and problem solved. Thanks Part Select!
Parts Used:
Refrigerator Defrost Heater Kit
  • Garryl from Carleton, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
14 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light inside fridge was flickering and clicking
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Parts Used:
Refrigerator Door Switch
  • bill from escondido, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
20 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leak in double outlet water valve/solenoid
This was an easy fix. The old one had cracked probably from the frige being left out in cold weather. Just remove the back cover. Unscrew the water line and two plastic lines and unplug the two plugs. Then remove a single screw that holds the valve in place and put on the new one and reattach everything. Good idea to recut the ends of the tubing to remove old crimp.
Parts Used:
Double Outlet Water Valve Kit
  • Joel from East Burke, VT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Wrench set
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Parts Used:
Refrigerator Door Switch
  • Lori from Chuluota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light not working in fridge
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
Parts Used:
Refrigerator Door Switch
  • Michael from East Meadow, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator coils would freeze up solid
Removed everything from inside freezer compartment (food and shelves) Removed inside backpanel that covered the coils. At the top of the coils is where the thermostat was attached. Removed old one and installed new. Has been working since.
Parts Used:
Refrigerator Defrost Thermostat
  • Walt from Sutter, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Parts Used:
Refrigerator Door Switch
  • Antonio from San Antonio, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Parts Used:
Refrigerator Door Switch
  • Duncan from Metairie, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
Parts Used:
Refrigerator Door Switch
  • Dave from Manchester Center, VT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water to Ice Maker
Very easy. Pull out refrig from wall to access the rear, turn off ice water line and Unplug refrig from wall outlet. Take socket and unscrew the one (1) tap holding the unit.
Remove the electric conections, pulling out from unit (there is nothing holding it in place but friction).
Remove the main water tube (have papber towel for water drip, there will be some)
Remove the two water tubes on top of unit (noting which tube goes to which relay)
Reconnect electric connectors to the new unit, reonnect water tubes to the new unit, screw down the new unit.
Turn water on and plug refrig back into AC outlet.
That's it, 20-30 min.
Parts Used:
Double Outlet Water Valve Kit
  • James from Jones, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the HMG641430