This end cap can be used for the right or left side of the refrigerator door shelf or the freezer door shelf. It is white in color, made of plastic material and measures about 2 inches high by 3 inches deep. This might need to be replaced if it has broken or worn over time. This repair requires no tools. You will need to open your fridge,...Read more pull upwards on the existing end cap, and pull outwards. There is a locking tab on either end so it does not matter if the top or bottom comes out first. Slide the new end cap onto the rail and it is installed.
This Defrost Timer works like a clock by switching on the defrost heater circuit after a predetermined amount of compressor run time. This allows the defrost circuit to clear the evaporator of ice or frost to maintain proper airflow. The defrost timer is located in the control housing which is in the refrigerator section of your appliance...Read more. If this part is not working, it can lead to temperature increases in your refrigerator. If the compressor circuit fails, no cooling will take place; if the defrost circuit isn't activated, ice will quickly build up on the evaporator coils and reduce airflow and efficiency. If the timer doesn't advance or if the contacts have no continuity, the timer will need to be replaced. This timer measures approximately 3 inches long and 2.5 inches wide, and is constructed of plastic and metal. It comes in black/white/silver and is sold individually. This replacement part features 1 defrost timer.
This OEM 40 watt appliance light bulb is used for some ranges, refrigerators, freezers, and microwaves. Simply locate the existing bulb, unscrew it from its socket, and replace with new light bulb. If the existing bulb is broken in the socket, disconnect the power to the refrigerator and use a pair of needle nose pliers to grip the intern...Read moreal fragments of the bulb to unscrew. Replace with the new bulb and reconnect the power to the refrigerator. These bulbs are sold individually and are a commonly replaced part; consider ordering a spare.
This white door shelf bar is approximately 31 inches long and provides storage space on your refrigerator door. If it becomes loose, cracked, or detached, it needs to be replaced. A damaged shelf bar can lead to sagging and insufficient support for your groceries. To remove the old shelf bar, release the retaining clips or brackets and sl...Read moreide it out carefully. You can cut this retainer bar to fit your fridge model. When purchasing this OEM replacement part, check how many your fridge needs as this shelf bar is sold individually.
The run capacitor helps the compressor kick on and off while maintaining a constant temperature in your fridge and freezer. You may need to replace your run capacitor if your refrigerator or freezer section will not start, if they are too warm, or if your refrigerator has become too noisy. Replacing the run capacitor is a relatively easy ...Read moreproject. For this repair you will only need a 1/4 inch nut driver and needle nose pliers. Remember to disconnect the power and water supply line to the unit before you begin this repair. For full step by step instructions, simply click on the video below.
This is the replacement crisper drawer cover support for your refrigerator. The crisper shelf rests on the support, which keeps it level. If your drawer cover or shelf will not stay level, or will not stay in place, the support may be damaged. The support is held in place on the refrigerator wall with a drive pin. To remove the damaged su...Read morepport, simply drive the pin all the way in, and use a putty knife to pry the support from the refrigerator wall. At this point, pull the drive pin out and replace the old support with the new one. This is an OEM part and is sold individually.
This crisper drawer frame is designed to support the crisper pan and hold the glass shelf above it, helping maintain organization and airflow within your refrigerator. Made of durable white plastic with a raised edge, it fits select models from Frigidaire, Kenmore, Gibson, and Electrolux. Please note that this replacement part includes th...Read moree frame only; the glass shelf is sold separately. For proper installation, simply remove the old frame and position the new one in place.
This evaporator fan blade is a genuine OEM part that is sourced directly from the manufacturer. The evaporator fan blade circulates air through the refrigerator to control the amount of cold air goes that goes to internal compartments of the unit. It may need to be replaced if the fridge is noisy or not cold enough. This part is made of p...Read morelastic and is sold individually. It will be necessary to disconnect power to the refrigerator and empty the freezer compartment of the refrigerator. The tools needed to complete this repair are a 1/4 inch nut driver and a pair of needle nose pliers.
The ice cube tray is made of plastic, is white in color, and is sold individually. This is a part for your freezer. The ice cube tray is sturdy but flexible to allow you to easily release the ice once it is frozen. The ice cube tray is what holds the water that eventually freezes into ice before being used. This tray measures approximatel...Read morey 11 inches long and 4 1/2 inches wide and holds 12 cubes at one time. The frigid temperature of the freezer can cause these trays to crack over time. This part is genuine and comes right from the manufacturer.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Clicking sound then within a minute clicking again, not cooling.
81 of 97 peoplefound this instruction helpful.
Melvin from Semmes, AL
Easy
Less than 15 mins
UNPLUG REFRIGERATOR. Carefully remove relay from the side of the compressor. You shouldn't need a tool to do this, if it is hard you can gently pry the edge with a flat head screw driver just to loosen. Unplug white and red wires from relay, noting that the white wire goes in the hole with a #2 stamped beside it. Shake old relay, if it r
... Read moreattles like a baby rattler then it's most likely the problem. Replace wires into the new relay and plug back into the compressor.
Read less
Was this helpful?
Thank you for voting!
Side-by-side .. freezer working, fridge not cooling
48 of 52 peoplefound this instruction helpful.
Tad from Lancaster, OH
Easy
15 - 30 mins
Screw drivers
My freezer was frozen but my refrigerated side was not cooling, the temp was actually around 60-degrees. After inspecting i noticed no air was flowing through the vent from freezer side to fridge side. I removed everything from freezer and took the back wall panel off inside freezer section and immedietely noticed alot of ice on coils etc
... Read more. After researching i found the defrost timer was not working and thus allowing frost and ice to build up on coils and block air flow. My defrost timer was located on the front bottom left behind kick panel, using a phillips screwdriver i removed 2 screws and then disconnected wire harness to the defrost timer. Then i inserted new defrost timer and connected wire harness and then put the 2 screws back in. My fridge is now working great and the ice build-up is gone and i am getting good air flow .. temps on fridge side are now between 32-34degrees. This was an easy project and saved me alot of money doing myself
Read less
Was this helpful?
Thank you for voting!
Wouldn't hold temp.
49 of 58 peoplefound this instruction helpful.
Laurence from Overland Park, KS
Really Easy
Less than 15 mins
Nutdriver, Screw drivers
I'm too young to die so I unpluged the refriderator first. The cold control is mounted in a plastic housing at the top of the freezer compartment that is held in place by two screws on the back side. I removed them with a nutdriver. Pull off the knob and use a screwdriver to release the control from it's bracket and pull off the 3 wire
... Read mores noteing where they go. Slide the sensing element out and remove the plastic sleeve. Stragihten the sensing element on the new control and slide on the plastic sleve. Slide the sensing element in place, push the wires onto the terminals and snap the control into the bracket. Re-install the two screws and the control knob. Plug it in and you're done. It took longer to write this than to replace the control.