Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
The control board generated clicking noise. Temperature display wrong values.
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay. The Ge profile refrigerator was 15 years old. First I disconnect the power cord, I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor. Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
Pulled the two wires out from the access hole in the lower part of the refrigerator. Put them in the spade connectors on the new switch, and pushed the switch into place.
Exposed evap defrosted with heat gun exposed defrost element defrost termination switch ok therminster didn’t check out the thermistor sends the signal to logic panel then run the the freezer ice machine and refer temps it took 24 hours before the system starting to show results freezer compartment 10 below ice compartment 0 degrees refer temp 37 degrees one refrigerant three different temps system is running at optimum performance 450.00 $ service call the thing with GE appliances there is no wiring diagram .thankyou parts select .ill use you on all domestic service calls.
Bad switch for door prevented interior light from coming on
Just as your video described, although due to the age of the fridge, it took a bit longer to remove the defective switch. Your video made this so simple, I can't imagine why we lived with a dark fridge for so long! I was ready to buy a whole new fridge, as repairmen are often nonexistent for small repairs. I am the biggest fan of your company & it's repair video. THANK YOU SO MUCH
Using plyers Pulled old switch down and out. Put new one in and pushed new switch up into position. The switch plugs into the contacts, no wiring needed. Worked like a charm. You saved me 200 dollars GE repair bill. Thanks
Temp. Sensor was under an egg shaped cover on the left side wall in the refrigerator. Remove the cover, cut the two wires to the old sensor and remove it. Connect the new sensor to the two wires using butt connectors. Replace cover and done.
coils were icing up and refrigerator section was warm freezer was cold
Unplugged unit and removed vented cover over compressor section. The run capacitor is a simple fix 1 Phillips head screw and 2 spade wire connectors. For the temperature sensor I had to remove all drawers and the ice maker to remove the back cover to expose the condenser. Put a bowl at the drain stem in the rear of the unit and used a heat gun to defrost the coils on the condenser. Cut the wire about 3" from the sensor end . cut about the same off the new sensor stripped the wires put shrink wrap on each wire, attached butt connecors . heat gun for the shrink wrap and reassembled everything. Simple job that took about a half hour to do both. I will monitor the fridge for a couple of weeks to see if I need to change the control board.