Sticking Light Switch
122 of 178 people found this instruction helpful.
  • Jonathan from Lilburn, GA
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
I applied some tips learned by reading other reviews. So before I started I grabbed my trusty vise grip pliers and a small screw driver. I locked onto the switch actuator, the part that the refrigerator door pushes in, with the vise grips and pulled on it just hard enough to get the screw driver inserted in the right side to push in the c atch clip so the switch could be pulled out further each time the catch clip was depressed to the next detent. Then I used the screw driver on the left site to encourage the switch past the detents on the left and very quickly the switch was out of the mount. The wires from the refrigerator pulled out with the old switch. I unplugged the old switch from the wires and plugged in the new switch and shoved the new switch back into the mount, wiggled it a couple of times to make sure it was secure and the job was done. Once I applied the vise gripes at first, the whole job took less than a minute.
Was this helpful?
Thank you for voting!
refrigerator was not cooling but the freezer worked fine.
93 of 110 people found this instruction helpful.
  • Wanda from Cabins, WV
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
My husband put on the defrost timer. At first I thought the part was not going to fix the problem. After about 5 hours my refrigerator was still warm. I went to work and when I got home that evening my refrigerator was cooling and down to 28 degrees. So if you replace this part wait at least 12-24 hours. Give it time to stablize. My husband says it has to go through its cycle. It works on a 24 hour timer. My refrigerator is working fine and this has saved me alot of money. My husband says, once you put on the timer you may have to use a flat screwdriver and turn the small dial clockwise one click to start it. He removed the kick grill and replaced the part. Dont forget to shut breaker off to replace this part. Turn power back on and start the timer. We are so happy that we now have a working refrigerator.
Was this helpful?
Thank you for voting!
The cover cracked and was unable to hpld the crisper drawers
64 of 71 people found this instruction helpful.
  • paul from allison park, PA
  • Really Easy
  • Less than 15 mins
Removed the crisper drawers, then the glass top shelf insert, then cleaned the area before sliding in the new cover and then replacing the crisper drawers and the glass top insert.
Was this helpful?
Thank you for voting!
display showed dE
75 of 119 people found this instruction helpful.
  • Nancy from Hamburg, NY
  • Easy
  • Less than 15 mins
  • Nutdriver
popped off front grille, removed 2 screws for bracket, then had to remove one screw for timer. unplugged old timer, reversed procedure, all works.
Was this helpful?
Thank you for voting!
Fridge smelled like something electronic was burning
50 of 59 people found this instruction helpful.
  • BENJAMIN from LAKESIDE, CA
  • Easy
  • 15 - 30 mins
  • Nutdriver
Removed the back cover of the fridge with it still pluged in. The next time the compressor tried to kick on, a small piece of black plastic next to the black tank caught fire, and then went out. I unpluged the fridge, unpluged the two wires feeding the black box. Then the box unpluged from the tank. I searched on the internet for the part using the model #. It ended up being a overload/ptc or relay. There was a smaller black box attached with I think is some sort of an overload. I unplugged the overload and it plugged right into the new relay I had overnighted. Although the new relay was white (not black) and the plug attachments were in different locations, it work great.
Was this helpful?
Thank you for voting!
broke shelf
40 of 45 people found this instruction helpful.
  • allan from brighton, MI
  • Really Easy
  • Less than 15 mins
easy fix... good price fast shipping, thanks
Was this helpful?
Thank you for voting!
Everything was freezing in the bottom and top
26 of 29 people found this instruction helpful.
  • Thomas from Germantown, TN
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Pulled out the control sensor on the ceiling of the fridge. (2 screws) Took a picture with phone on how everything was installed. Unplugged all wires and pulled out Control Temp sensor. Installed new one and attached all wires. Installed back in fridge and plugged it back in. Everything works like new.
Was this helpful?
Thank you for voting!
refrigerator would not defrost
21 of 23 people found this instruction helpful.
  • Donald from worthington, OH
  • A Bit Difficult
  • 15 - 30 mins
  • Screw drivers
Look were timer was located, in my refigerator is next to the dial to ajust the temperature. used a screwdriver to get panel off. replaced timer then used a straight screwdriver to advance timer to turn on compessor . monitor temperature . checked out.
Was this helpful?
Thank you for voting!
The refrigirator light would not come on.
26 of 44 people found this instruction helpful.
  • Jania from Novato, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Was this helpful?
Thank you for voting!
The drawers and shelf in my refrigerator broke
21 of 31 people found this instruction helpful.
  • ROSANNE from HAZLE TOWNSHIP, PA
  • Really Easy
  • Less than 15 mins
I ordered new ones The came really fast. One was broken . My exchange was handled with great speed and excellent customer care.
Was this helpful?
Thank you for voting!
Neeed extra shelves for new purchased refrigerator
22 of 35 people found this instruction helpful.
  • Hollis from Daphne, AL
  • Really Easy
  • Less than 15 mins
Simple install. .
Was this helpful?
Thank you for voting!
The plastic cover broke - probably too many heavy bottles on it.
13 of 14 people found this instruction helpful.
  • lotte from Laguna Woods, CA
  • Really Easy
  • 30 - 60 mins
Had to take out everything on the shelf & pull out the vegetable draws, then proceeded to clean it all. Had to take out the glass inset in the cover & wash that. After that I just slid it in - piece of cake! The hardest part was to get the plastic cover off the new part!

By the way - I'm 87 yrs old.
Was this helpful?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
19 of 33 people found this instruction helpful.
  • Terry from Simi Valley, CA
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring s o it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Was this helpful?
Thank you for voting!
Existing light switch was hard to remove.
14 of 19 people found this instruction helpful.
  • Stephen from Jupiter, FL
  • A Bit Difficult
  • Less than 15 mins
  • Screw drivers
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Was this helpful?
Thank you for voting!
malfunction of the cold control (wearing out after 15 years)
12 of 14 people found this instruction helpful.
  • john from Philadelphia, PA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
1. Disconnected 120 VAC power supply from refrigerator. 2. Removed 2 philip screws from horizonal panel containing the thermostat. (Panel is in refrigerator section). 3. Removed plug module from panel which freed the pa nel which allowed me to remove panel to do repair. 4. Removed wires from thermostat (cold control), and mechanically removed thermostat from panel and installed new cold control (thermostat). Replaced wires on control. 5. Replaced panel and reinstalled 2 philips screws. 6. time to repair about 15 minutes.
Was this helpful?