Microwave Door Interlock Switch – Part Number: W10269458
$31.58
In Stock
Microwave Door Interlock Switch
★★★★★
★★★★★
(12)
Part #W10269458
This door interlock switch is a genuine replacement part designed for use in microwaves. It serves a critical safety function by preventing the microwave from operating when the door is open. Because proper operation of the microwave’s shielding and interlock system is essential for user safety, this part should be installed by a qualified service technician. After installation, the interlock switches and microwave shielding must be thoroughly tested to ensure the appliance meets safety standards.
DIODE – Part Number: W11256462
$26.82
In Stock
DIODE
★★★★★
★★★★★
(10)
Part #W11256462
This diode, or high voltage diode, is used in microwaves. It is an electrical current control device that ensures power flows in one direction and not the other way. If your microwave produces no heat, heats inconsistently, or gets noisy, replacing this part can be the solution. The tools needed for this replacement are a nutdriver, pliers, and screwdrivers. First remove the microwave cover, then remove the old part by disconnecting the small thermostat. Replace with the new diode. Remember to use the diagram provided by the manufacturer for more instructions.
R Ceramic Fuse 20 A – Part Number: W11707984
$36.85
In Stock
R Ceramic Fuse 20 A
★★★★★
★★★★★
(7)
Part #W11707984
If your microwave is not turning on it could be due to your fuse needing to be replaced. This part protects the microwave by shutting it off if there is an electrical surge. This fuse is just over an inch long, is metallic on both ends and ceramic in the middle. Before beginning this repair, unplug the appliance and wait a few minutes before starting. Remove the outer cabinet which is held in place with two screws. You will then locate the power cord which will lead you to the fuse holder. Determine if the fuse has blown. Using an ohmmeter, you should be able to figure out if it has blown. A proper reading is zero ohms, if it reads as anything else then your fuse has in fact blown. Simply snap the old fuse out of place and place the new one in.
Door Switch - 250V – Part Number: W10211972
$47.40
In Stock
Door Switch - 250V
★★★★★
★★★★★
(2)
Part #W10211972
This microwave door interlock switch is a critical safety component designed to prevent the appliance from operating when the door is open. It functions by detecting the door’s position—open or closed—and relaying this information to the microwave’s electronic control system. This ensures the unit only activates when the door is securely latched. Commonly used in microwave models experiencing issues such as failure to start or lack of heating, the switch plays a vital role in maintaining safe operation. Installation involves accessing the internal door latch mechanism and replacing the switch, which typically requires basic tools and careful handling to avoid damage to surrounding components. The switch is compact and designed to fit seamlessly within the microwave’s door assembly.
Microwave Spacer – Part Number: 8184109
$9.62
In Stock
Magnetron – Part Number: W10245183
$155.05
In Stock
Magnetron
★★★★★
★★★★★
(3)
Part #W10245183
This part is used to generate microwave energy/heat.
Door Switch – Part Number: W10211974
$46.34
In Stock
Door Switch
★★★★★
★★★★★
(3)
Part #W10211974
This part keeps the microwave from running when the door is open.
Door Latch – Part Number: 4393913
No Longer Available
Door Latch
★★★★★
★★★★★
(1)
Part #4393913
This latch is sold individually. Two might be required for your model.
Interlock – Part Number: 8205572
$9.62
In Stock
Interlock
Part #8205572
This part houses the switches.
COOKWARE – Part Number: W11512490
$59.47
Special Order
Plate Cam – Part Number: 8183824
No Longer Available
Plate Cam
Part #8183824
Sold individually.
THRMST-FIX – Part Number: 4393943
No Longer Available
THRMST-FIX
Part #4393943

Common Symptoms of the CMT102SGW0

How this model fails, and the parts that fix it.

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
My microwave began suddenly making a loud humming noise while cooking food.
131 of 258 people found this instruction helpful.
  • Lindsay from Nampa, ID
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers
My microwave began suddenly making a loud harsh humming noise while cooking food. I did not let it go on long enough to know if it cooked the food or not. I did some Internet research and learned that it was likely the Magnetron. The test for this was to run the microwave for at least a minute on the lowest power setting and see if the no ise cycled on and off. It did, so I (actually, my wife) ordered the part from partselect.com using the model number. I was successful in replacing the part, and we are back to microwave popcorn and quick defrost for a price that was less than a service call, however, it was time consuming, required a large work area, and access to 5 out of 6 sides of the unit. So proceed at your own discretion

Caution:

The first thing in every set of repair instructions was to discharge (short-circuit) the capacitor, as it may store large (as in lethal) amounts of electricity even when it is not connected to a power source. I had never done this, but found these instructions:

“Discharging your microwave's capacitor is absolutely essential in preventing injury to your microwave, your tools, and yourself. A capacitor stores a large amount of electricity even when your microwave is unplugged, and it must be discharged before beginning any repair.
A capacitor is discharged by creating a short circuit between each of the two capacitor terminals, and between each terminal and the chassis. The chassis is the metal mounting (bare metal surface) of the capacitor. Read these directions thoroughly before you proceed.
With your microwave unit unplugged, touch the blade of a well insulated screwdriver to one terminal. Gently slide the screwdriver forward until it reaches the other terminal, holding it there for a few seconds. Be aware that this often results in a loud and startling 'POP'.
Repeat this procedure in order to create a short circuit between each capacitor terminal and the chassis (bare metal mounting plate surface). This same method can be applied to a capacitor having three, and not two, terminals.”
I had not run my microwave in over a week, and then while my part was shipping, left my microwave 'unplugged' for more than two days, and my capacitor apparently discharged itself, although I did go through the above procedure carefully and completely - just in case.
Step-By-Step:
1. You must remove your microwave from the cabinets - it is impossible to repair otherwise. This is best accomplished with 2 strong people - my wife and I made it work, but wished for another guy.
a. While supporting the microwave, remove the two screws coming down through the cabinet above.
b. Lift the rear of the microwave as much as possible, then tilt the front down - there is a clip high on the left side, as well as the hinge/clips on the bottom.
c. If you do not lift it off the wall all at once, you may have to lift the rear even farther to remove it from the hinge/clips on the bottom.
Important Note: Always beware of the microwave door, if it is bent or broken and cannot retain a seal, the microwave not function as a safety feature to keep from releasing microwaves.
2. Remove the vent cover on the top/front of the microwave - be careful, it's plastic.
3. Remove the vent cover and light panel on the bottom of the microwave - this is several screws and some simple wire clips.
4. Remove the "shell" (top and sides) of the microwave - this is several more screws on the back. Make sure to remove the plate that is holding the cord in place on the top.
5. Remove the interface panel by the screws on the top (which had been hidden by the vent cover) - the wires can remain attached, just slide it aside.
6. Remove the metal cover on the right side at the rear; this will expose the Magnetron and the Capacitor. Remember to immediately test and discharge the capacitor!

7. After you discharge the capacitor, remove the other cover plate and the support bracket - in case you haven't noticed, this is a time and space consuming operation.

8. You
Was this helpful?
Thank you for voting!
Microwave made very loud noise while on. No heat.
52 of 87 people found this instruction helpful.
  • Sleiman from Miami, FL
  • Easy
  • More than 2 hours
  • Pliers, Screw drivers
Unless you have a very comfortable background with electronics and electricity, I don't necessarily recommend taking apart a microwave. If you are very handy and are going to be VERY cautious to follow the rules of discharging caps and testing voltages before moving forward, then go for it. That said, I took the microwave off and apart. Not knowing where to find the parts, I was fortunate that the installer put the instruction book for the microwave inside the front vent slot above the touchpad for reference. it details the location of every part and it tells you very clearly what each part you test should show specific to this microwave on your multimeter. Find this guide online if you don't have it. Turn on the microwave for 20 seconds with a glass of water to make sure it's not heating - that with the noise means it's eeither the magnetron, cap, or diode. Read the notes on this site for all of the basic things to look for with the magnetron, diode, and capacitor. Once comfortable with the guide, locations of those devices, and how to test, then take it down and apart. Unfortunately, I didn't do all those things in that order, and it only wasted a lot of time trying to find the parts. Once I found the parts and put all the screws and covers back for all the areas that didn't need to be accessed for the repair, testing went quickly. The diode was bad. Ordered a new one and had it in 3 days or so. That means your microwave will be apart and sitting somewhere for a little while until you get the part and have time to repair it. Putting the diode back isn't too bad. Reassemble the microwave and put it back up again. If i had to do it again, it would take me 20 to 30 minutes once the microwave was down and on a table. Also, I used some bricks with towels over them or you could use some sawhorses to keep the microwave elevated so you can plug it in and run it after installing the new component. Again, make sure you discharge the cap before touching anything again even if you didn't run it, but just plugged it in.
Was this helpful?
Thank you for voting!
Humming sound, not heating.
43 of 63 people found this instruction helpful.
  • Fausto from Miramar, FL
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
I turn off the income electricity by shutting down the corresponding circuit breaker. Then, I removed the control panel from the microwave which gave me access to the capacitor and adjacent diode. After that i unscrewed the defective diode and replaced it with the new one and BINGO!
Was this helpful?
Thank you for voting!