BEARING – Part Number: 4280A20004M
$12.85
In Stock
Range Hex Nut – Part Number: WP488130
$8.55
Special Order
Range Hex Nut
★★★★★
★★★★★
(2)
Part #WP488130
This hex nut is an authentic Whirlpool part that is sourced directly from the original equipment manufacturer, and will fit a variety of appliances including ovens, microwaves, refrigerators, air conditioners, and dishwashers. It is a metal part with a threaded hole to fasten parts in the appliance together. It is common for this part to wear out; it is recommended to order a spare. To replace this part the tools needed are a nut driver or wrench. This nut features a built-in external tooth lock washer, which is used to help keep the nut in place.
Remote Control – Part Number: AKB74375404
$79.80
In Stock
Remote Control
Part #AKB74375404
FILTER,AIR – Part Number: 5230A20064K
$28.42
Special Order
FILTER,AIR
Part #5230A20064K
AC Fan Motor – Part Number: 4681A20122B
$238.59
On Order
AC Fan Motor
Part #4681A20122B
This outdoor DC motor assembly is a genuine replacement component designed for use in air conditioning and heat pump systems. It powers the outdoor fan, which circulates air across the condenser coils to support efficient cooling and heating. By converting electrical energy into rotational motion, the motor helps regulate airflow and maintain consistent temperature control. A failing motor may cause symptoms such as reduced airflow, unusual noise, vibration, or a humming sound without rotation. Replacing the motor can restore proper operation, improve energy efficiency, and reduce noise. Installation should be performed with the power disconnected to ensure safety. This part is compatible with select models and should be verified for fit before installation.
Fan Assembly,Cross Flow – Part Number: 5901A20017H
$67.82
Special Order
Fan Assembly,Cross Flow
★★★★★
★★★★★
(2)
Part #5901A20017H
This is a cross flow fan assembly for an air conditioner. This is a genuine replacement part sourced directly from the original manufacturer. A cross flow fan assembly is a key part of your air conditioner. It prevents the internal parts of your appliance from overheating by creating a wide and even flow of air throughout the inside of the air conditioner. If you are noticing your appliance getting too warm or overheating, it is recommended to stop using the appliance before replacing the fan. Continuing to use the appliance could cause internal damage to other parts. It is made entirely of plastic, and is off-white in color. This part is sold individually.
Fan Assembly,Propeller – Part Number: 5901A10033A
$53.20
In Stock
Fan Assembly,Propeller
★★★★★
★★★★★
(1)
Part #5901A10033A
This propeller fan assembly circulates air efficiently to support cooling, ventilation, or heat distribution. Balanced airflow helps protect internal components from overheating and improves performance consistency. Replacing a worn fan restores quiet operation and dependable airflow throughout the system.
Capacitor – Part Number: EAE43285408
No Longer Available
Capacitor
Part #EAE43285408
If your air conditioner is not blowing cold air, the problem may be in the capacitor. If the capacitor fails, the compressor will not start and the fan will only blow warm air. The compressor and capacitor are located inside the cabinet and to gain access you will need to remove the cover. If the capacitor does not show any visible signs of damage you may require a qualified technician to test it. Make sure that the replacement capacitor has the same specifications as the original. NOTE: Because capacitors carry a charge even when the unit is disconnected from the power, use extra caution when performing this repair.
Fan Assembly,Cross Flow – Part Number: 5901A92441E
$75.13
In Stock
Fan Assembly,Cross Flow
Part #5901A92441E
This cross-flow fan assembly delivers even air distribution across internal components. Designed for steady airflow, it supports temperature regulation and efficient operation.
PCB Assembly,Main – Part Number: 6871A20901D
No Longer Available
PCB Assembly,Main
Part #6871A20901D
THERMISTOR ASSEMBLY,NTC – Part Number: EBG61106816
$33.69
In Stock
THERMISTOR ASSEMBLY,NTC
Part #EBG61106816
Thermistor,NTC – Part Number: 6323A20002L
No Longer Available
Thermistor,NTC
Part #6323A20002L

Common Symptoms of models starting with ASC1

How this model fails, and the parts that fix it.

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Motor Assembly, DC, Stepping had quit working which caused the loover on the front of the air conditioner to remain open
6 of 10 people found this instruction helpful.
  • DOUG from SHERIDAN, WY
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
Main problem was removing the cowling from the LG head unit as I had no instructions on how to do it. I had watched the previous technicians that had worked on the unit remove it. Once the cowling is removed all that needs done is remove the 2 mounting screws and unplug the old motor, plug in the new motor and remount it with the 2 screws . Then the cowling has to be reinstalled.
Was this helpful?
Thank you for voting!
Plastic fan broke when I attempted to clean it
1 of 2 people found this instruction helpful.
  • Donna from Austin, TX
  • Difficult
  • 1- 2 hours
  • Nutdriver, Pliers, Screw drivers, Socket set
The inside air blower for the LG mini-split collects lint and clogs up. Removing the broken blade requires removing the outer plastic housings, then screws at each end of the blower housing. Some screws at the control end require removing the control units first. There is a set screw that connects the fan to the motor shaft at the control end. There is a missing blade in the fan to allow access. This screw was lock-tighted in place and required significant force to loosen. The new fan took some wiggling to get it onto the shaft. Then replace the screws at each end of the fan housing, followed by the control unit screws, and the plastic outer covers. It was not an easy job. I used more care with a small bottle brush to clean the second fan unit and avoided breaking that fan.
Was this helpful?
Thank you for voting!
Capacitor went out
2 of 6 people found this instruction helpful.
  • Al from CROSS PLAINS, TX
  • Really Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
Unplugged and replugged everything and it worked very easy job thank you
Was this helpful?