Steady compressor operation relies on the electrical support provided by this refrigerator run capacitor. It creates a phase shift in the motor circuit to help the compressor run as designed while circulating refrigerant through the cooling system. A failed capacitor may contribute to unusual humming, difficulty starting, or reduced cooli...Read moreng performance. Replacing a faulty capacitor helps restore proper electrical conditions for compressor operation. The component stores electrical energy and can retain a charge after power is disconnected, requiring care during handling and replacement. This is an OEM part sourced directly from the manufacturer.
This gasket retainer clip kit is for freezers. There are 24 pieces in this kit. The clips are what secure the gasket and liner to the freezer lid. The clips are white in color and made of plastic. If you notice frost build up in your freezer or that is it is not maintaining its temperature, this might be because the retainer clips have br...Read moreoken, and this has caused the gasket to become loose. This is a genuine OEM part that is obtained right from the manufacturer, ensuring a quality repair.
This filter drier removes moisture and traps small particles in the refrigerator sealed refrigerant circuit. It helps keep dirt, metal fragments, and moisture from moving through the cooling system. The component measures approximately 11 inches long. A blocked or faulty filter drier may restrict refrigerant flow and contribute to poor co...Read moreoling even while the compressor runs. These symptoms can also come from other sealed system faults, so confirm the failed component before replacement. Match the filter and tubing connections to the appliance service requirements before selecting the replacement. This is an OEM part sourced directly from the manufacturer.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Clicking sound then within a minute clicking again, not cooling.
81 of 97 peoplefound this instruction helpful.
Melvin from Semmes, AL
Easy
Less than 15 mins
UNPLUG REFRIGERATOR. Carefully remove relay from the side of the compressor. You shouldn't need a tool to do this, if it is hard you can gently pry the edge with a flat head screw driver just to loosen. Unplug white and red wires from relay, noting that the white wire goes in the hole with a #2 stamped beside it. Shake old relay, if it r
... Read moreattles like a baby rattler then it's most likely the problem. Replace wires into the new relay and plug back into the compressor.
Read less
Was this helpful?
Thank you for voting!
buttom of refrigerator not cold
23 of 29 peoplefound this instruction helpful.
Giuseppe from brick, NJ
Really Easy
Less than 15 mins
Screw drivers
unplug it, pulled compressor start relay,which i thing it was the problem, but i replace bolt, very easy.