This refrigerator door hinge bushing is a durable white plastic component that provides a smooth pivot point for the hinge pin, helping keep the door properly aligned and sealed. It is commonly used to correct doors that sag, make noise, or are difficult to open or close due to a worn or damaged bushing. The bushing installs at the door h...Read moreinge pivot point and typically requires removing the hinge bracket with a 10?mm socket. Color is white, and size and dimensions may vary by refrigerator model.
This ice maker assembly is a genuine OEM replacement unit for LG refrigerators. It is responsible for producing and dispensing ice cubes. You can find the ice maker assembly inside the freezer compartment of your fridge. The assembly consists of several parts, including a water inlet valve, ice mold, thermostat, and motorized assembly for...Read more dispensing ice. If any of these components fail, your ice maker will be unable to produce any ice or may only release small amounts of ice. This complete assembly contains all the parts you need to replace your faulty unit and restore your refrigerator.
This water tubing clip holds the water fill tube in place in your refrigerator. The water fill tube attaches and supplies water to the ice maker/water dispenser in your fridge-freezer. If the tubing is in working order, but is hanging loose inside the unit, the issue could be that the clip meant to hold it in place is broken. If this is t...Read morehe case, you should look to replace the clip. This clip is made of black plastic, and is just over half an inch long. This is a genuine OEM replacement part, and is sold separately.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
old bushing worn and broken
23 of 43 peoplefound this instruction helpful.
Jerry from CORSICANA, TX
Really Easy
30 - 60 mins
Screw drivers, Socket set
removed the upper freezer door to access screws to remove lower door. laid bottom door on its side, removed bad bushing, put new bushing in, put bottom door back on refridge, put upper door back on fridge. Door worked easy as when new. good closure of door and story..Happy customer, and wife even happier.....thank you....
Was this helpful?
Thank you for voting!
bottom door dropped slightly and bottom hinge area rubbing on steel door support
12 of 27 peoplefound this instruction helpful.
Louis from PHILADELPHIA, PA
Really Easy
30 - 60 mins
Screw drivers, Socket set, Wrench set
removed 3 fasteners for top door and placed freezer door aside, then removed 3 more fasteners on bottom refrigerator door and place that aside. replaced bushing on lower door bracket and reversed the above procedure to reinstall doors.
Was this helpful?
Thank you for voting!
icemaker stopped working
4 of 5 peoplefound this instruction helpful.
Norris from Telford, PA
A Bit Difficult
30 - 60 mins
Screw drivers
This is bottom drawer type frige. Icemaker is inside (not in the door) and hard to reach. I first tested the solenoids by disconnecting them and using a test cord, energized them independent of the frige wiring. They worked ok. Note: this frige has (2) solenoids going to the icemaker. And it has (3) solenoids serving the water disp
... Read moreenser. The icemaker solenoids are wired in parallel. I removed the icemaker by removing (1) screw from the bottom and loosening (2) on the top. Then removed icemaker as a complete unit disconnecting the wire connector at the same time. On the bench I tested the icemaker to verify it was defective. The wire harness has a 10 amp fuse in the black wire (hot wire). `The fuse was blown. This was sufficient to indicate the icemaker is shot. I did however, do some other tests. Cold resistance of the mold heater was 72 ohms. The timer motor was 4000 ohms. These measurements should be ok. I then activated the icemaker with a test cord, bypassing the blown fuse. The unit cycled one complete rotation then stopped. The mold heater worked. I tested the amp draw on the mold heater and it was only .1 amps. I should be a about .8 amps. I then cycled it again and then the timer motor began to sizzle and smell. Then it smoked and stopped mid-rotation. I then purchased a new icemaker. I believe the mold heater was going bad over time as this unit made ice but very slowly. This put extra strain on the motor as the mold was not releasing quickly. This damaged the motor causing it to fail.