EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details
Back
Back
Back
Keep typing for more specific results...
Keep typing for more specific results...

7479977710 Kenmore Microwave - Overview

Sections of the 7479977710

[Viewing 2 of 2]
Keep searches simple, eg. "belt" or "pump".
Light Bulb - 40W – Part Number: 8009
Light Bulb - 40W
★★★★★
★★★★★
(78)
PartSelect #: PS884734
Manufacturer #: 8009
This an authentic OEM 40-Watt replacement light bulb, used in a number of household appliances. It is specially designed to withstand extreme temperatures, which is why these replacement bulbs are mos...
$19.54
  In Stock
Order now and your part arrives by May 14
Dryer Screw – Part Number: WP90767
Dryer Screw
★★★★★
★★★★★
(2)
PartSelect #: PS11746840
Manufacturer #: WP90767
This screw is sold individually.
$7.47
  In Stock
Order now and your part arrives by May 14
Ceramic Fuse - 20 amp – Part Number: WPM0805101
Ceramic Fuse - 20 amp
★★★★★
★★★★★
(3)
PartSelect #: PS11747931
Manufacturer #: WPM0805101
This microwave fuse is just over an inch in length. It has a white ceramic center, and metal on either end. This is a twenty amp 250-volt fuse, and is used to power your microwave. If your microwave w...
$5.45
  In Stock
Order now and your part arrives by May 14
Screw – Part Number: WP489474
Screw
★★★★★
★★★★★
(1)
PartSelect #: PS11742753
Manufacturer #: WP489474
Sold individually.
$7.47
  In Stock
Order now and your part arrives by May 14
Capacitor – Part Number: 59001160
Capacitor
PartSelect #: PS2055682
Manufacturer #: 59001160
  No Longer Available
INSERT-DOOR/ACCESS – Part Number: 5300808908
INSERT-DOOR/ACCESS
PartSelect #: PS452106
Manufacturer #: 5300808908
  No Longer Available
USE MAC 30929P01 – Part Number: M4D35
USE MAC 30929P01
PartSelect #: PS183370
Manufacturer #: M4D35
  No Longer Available
THERMAL PROTECTOR – Part Number: M4D49
THERMAL PROTECTOR
PartSelect #: PS183383
Manufacturer #: M4D49
  No Longer Available
SHIELD, VENT – Part Number: M5D142
SHIELD, VENT
PartSelect #: PS183984
Manufacturer #: M5D142
  No Longer Available
INNER DOOR ASSEMBLY INCLUDES KEY #10, #11 – Part Number: M70D42
INNER DOOR ASSEMBLY INCLUDES KEY #10, #11
PartSelect #: PS185081
Manufacturer #: M70D42
  No Longer Available
CAVITY & FACEPLATE INCLUDES KEY #20 – Part Number: M77D55
CAVITY & FACEPLATE INCLUDES KEY #20
PartSelect #: PS185285
Manufacturer #: M77D55
  No Longer Available
USE MAC A4539605 – Part Number: M1D227
USE MAC A4539605
PartSelect #: PS180946
Manufacturer #: M1D227
  No Longer Available

Questions And Answers for 7479977710

Be the first to ask our experts a question about this model!

Common Symptoms of the 7479977710

[Viewing 1 of 1]
Won’t turn on
Fixed by
these parts
Fixing
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
microwave oven blew fuse
First I removed upper front grill by removing two Philips head screws on top and pulling off. This exposed the Philips head screw which holds control panel in place. After removing screw I pushed up on panel and it came off to expose fuse. With needle nose pliers I removed old fuse and again with pliers held new fuse in position. With the help of a bladed screwdriver, I pushed new fuse into holder, then replaced panel, screw and grill. This took less than 15 minutes even as one of the wires on control panel pulled out of connection and took some time to locate where to reconnect, otherwise was an easy fix
.
Parts Used:
Ceramic Fuse - 20 amp
  • tad from tamarack, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
27 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microve stopped working
Jenn-Air Microwave would not turn on. Clock worked , light worked, timer worked and would count down .I changed' Part #0813140 Switch, Micr} cost $8.99 plus shippingNow it works Thank You for good advise
Parts Used:
Ceramic Fuse - 20 amp
  • Denice from Montgomery, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
15 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave went pop and nothing would work.
I mistakenly thought I had to remove the microwave to get to the back, not so. I would have had access to what I needed to unscrew; but I have to admit the hassle of taking it down and putting it back equals having to work on it attached to the shelf-your call on how you do this. I unscrewed the front top to remove the vent piece that is across the top front of the microwave. This will reveal the control panel screw. (While you have the vent removed you might want to clean the vent and the exposed filter.) carefully lift and pull out control panel. I unplugged a piece as the wires were tied tight. It will not completely detach, so carefully tip it back from exposed insides. The fuse is not clear but white with silver ends so look in upper right for it. I popped it out and replaced it. Replugged the wired part to cover and carefully fit tabs in and slide down to secre. Replace screw, replace vent piece and secure screws on top of microwave. I plugged it in to test before putting it back above my stove.
Parts Used:
Ceramic Fuse - 20 amp
  • Deborah from STRUM, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!