62622200 Kenmore Microwave - Overview

Diagrams for 62622200

See every part. Know exactly what you need.

Enter a part description. DIY Heroes keep it simple, eg. "belt" or "pump".

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Light Bulb - 120V 30W – Part Number: 6912W1Z004B
$13.73
In Stock
Light Bulb - 120V 30W
★★★★★
★★★★★
(16)
Part #6912W1Z004B
Restore visibility in the microwave cavity or over the cooktop with this replacement incandescent lamp. The 30 watt bulb uses a screw base to connect to the light socket and provides illumination when the appliance lighting is activated. A burned out filament may leave the area dark while the microwave continues operating normally. Replacing a failed bulb restores light for checking food or viewing the cooking surface below. Disconnect power, allow the lamp to cool, and follow the appliance instructions for access to the bulb. This is an OEM part sourced directly from the manufacturer.
Glass Cooking Tray – Part Number: 1B71961H
$45.29
On Order
Glass Cooking Tray
★★★★★
★★★★★
(15)
Part #1B71961H
This OEM glass cooking tray is a removable glass plate, measuring 13 inches in diameter, that spins inside the microwave during operation. It ensures that heat is evenly distributed in the microwave to properly heat or cook the food. Over time, the heat generated in the microwave can cause the glass to warp and the plastic rollers to wear down. The glass can also crack or shatter accidentally. It is important to replace the glass as soon as it is no longer functioning well to prevent uneven heating and reduce any safety hazards from damaged glass. Carefully pull the old glass cooking tray from the microwave and clean the microwave cavity. Place the new tray onto the rotating mechanism, and properly align it with the rollers. Turn the microwave on and check to see that the tray is rotating freely.
Door Handle – Part Number: 5304440323
No Longer Available
Door Handle
★★★★★
★★★★★
(3)
Part #5304440323
Screws NOT included.
Charcoal Filter – Part Number: 5230W1A011B
$24.67
Special Order
Charcoal Filter
★★★★★
★★★★★
(11)
Part #5230W1A011B
This is the replacement charcoal filter for your microwave. It is approximately 8 inches by 5 inches. The charcoal filter removes cooking odors from the air that circulate through the microwave vent. You will likely need to replace the charcoal filter if you notice any damage to it, or if it has been in your microwave for a long time. This part is sold individually and is an authentic OEM part sourced directly from the manufacturer.
Micro Switch – Part Number: 6600W1K001D
$25.78
In Stock
Micro Switch
★★★★★
★★★★★
(27)
Part #6600W1K001D
This microwave door interlock switch responds to the door latch, helping prevent cooking operation while the door is open. Its small actuator changes the electrical contact when the door opens or closes. A worn or damaged switch may prevent the microwave from starting even when the door is fully shut. Replacing a faulty switch helps restore proper door detection within the safety interlock system. Internal microwave components can retain a dangerous electrical charge after unplugging, so disconnecting power alone does not make them safe to handle. This is an OEM part sourced directly from the manufacturer.
Microwave Damper – Part Number: 4900W1A001B
$21.95
In Stock
Microwave Damper
★★★★★
★★★★★
(5)
Part #4900W1A001B
Exhaust air passes through this microwave vent damper when the ventilation fan runs. The metal flap opens with outgoing airflow to let steam and cooking odours enter the exhaust duct, then closes when airflow stops to help limit outside drafts. A bent, warped, or stuck flap may restrict ventilation or allow air to flow back into the kitchen. Replacing a damaged damper helps restore free flap movement and proper exhaust operation, providing a movable barrier at the duct opening between fan uses. This is an OEM part sourced directly from the manufacturer.
Microwave Locker – Part Number: 4026W2A019A
$21.95
In Stock
Microwave Locker
★★★★★
★★★★★
(9)
Part #4026W2A019A
Secure door closure relies on this black plastic microwave door latch hook. Installed inside the door assembly, it engages the latch openings and operates the safety interlock switches when the door closes. A cracked hook or damaged latch may prevent the door from staying shut or keep the microwave from starting. Replacing a damaged latch helps restore proper mechanical engagement and door operation. The hook moves with the door release mechanism, allowing the door to open when released and latch again when closed. This is an OEM part sourced directly from the manufacturer.
Turntable Assembly – Part Number: 5889W2A012F
$27.36
In Stock
Turntable Assembly
★★★★★
★★★★★
(6)
Part #5889W2A012F
This turntable assembly, also known as a rotating ring, is a genuine OEM replacement part for your microwave. It is brown in color and about 10 inches in diameter. This part supports the glass turntable and keeps it in place. Replacing this part is very easy and requires no tools. Simply remove the glass tray, pop out the existing ring and replace with the new one.
Microwave Cook Auxiliary Holder – Part Number: 4930W1A069A
$16.45
In Stock
Microwave Motor Ac Synchronous – Part Number: 6549W1S013H
$48.35
In Stock
Microwave Motor Ac Synchronous
★★★★★
★★★★★
(5)
Part #6549W1S013H
If the turntable on your microwave does not rotate, or you can hear a grinding noise, the problem may be with the motor. The motor is typically located below the floor of the oven, and is accessed through the bottom. The motor is normally held in place with a retaining screw and will have two wires attached to it as well. If the motor is making a grinding noise it will need to be replaced. If the motor does not turn, you can check for voltage or continuity with a multi-meter. Make sure the power is disconnected from your microwave before beginning this repair.
Microwave Screwtapping – Part Number: 1TTL0402818
$16.45
On Order
Diode (Cable, Assembly) – Part Number: 6851W1A002E
$17.15
In Stock
Diode (Cable, Assembly)
★★★★★
★★★★★
(1)
Part #6851W1A002E
Current flows in one direction through this microwave high voltage diode and cable assembly, which works with the capacitor and transformer to supply the magnetron. This electrical process supports the microwave energy used to heat food. A failed diode may cause a loss of heating or unusual humming while the appliance runs. Replacing a faulty assembly helps restore normal high voltage circuit operation. Internal microwave components can retain a dangerous electrical charge after unplugging, so disconnecting power alone does not make them safe to handle. This is an OEM part sourced directly from the manufacturer.

Questions And Answers for 62622200

Ask our experts a question about this model and we'll get back to you as soon as possible!

Sort by:
  • 1
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Karen - For model number 62622200
November 12, 2024
Damper vent
Chris Boyle Profile
Hello Karen, Thank you for your inquiry. We show the compatible damper vent door as part# PS3524148 and the bracket as part# PS3523851. Good luck with your repair.
$21.95
In Stock
Microwave Damper
Was this helpful?
Thank you for voting!
  • 1

Common Symptoms of the 62622200

How this model fails, and the parts that fix it.

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Broken Handle
44 of 64 people found this instruction helpful.
  • Brent from Bend, OR
  • Easy
  • Less than 15 mins
  • Screw drivers
Removed the retaining clip that keeps the door on, took the door off. Removed the plastic rim that is clipped into place. Removed old screws holding on handle and replaced.
Was this helpful?
Thank you for voting!
Broken door micro switch. (unit does not start heating)
37 of 68 people found this instruction helpful.
  • JAMES from BILLINGS, MT
  • Very Easy
  • 30 - 60 mins
  • Screw drivers
Unplug the unit before servicing. Need phillips screwdriver. Open door. Use step ladder to access and remove 2 small screws from top of the room air diffuser at top of unit. Slide diffuser slightly to the left to align the diffuser's plastic tab on the left side to rotate toward you. (The wires for the front control panel are at the far l eft side of this difuser, but difuser is slotted for easy removal). Once the difuser is removed you will see 1 screw at the top that secures the pannel cover on the left side of the unit. Remove screw and slide this panel slightly up and out. This exposes the plastic frame that holds the upper and lower door switches. To locate the door switches and observe how they work, close and open the door and watch the door (bayonets) open and close the micro switches. Do the (red) buttons on top of the switches move up and down when the door bayonets push and release? If the buttons do not "pop" up when opened the switch is defective. The switch frame is secured with 2 screws. Remove screws and rotate the unit out for easy access to the micro switch(s). The internal (spring?) on my unit that is suposed to allow the red (visible) button on top of the switch to "pop" up when the door is opened was broken. Carefully pry the switch outward while being careful to lift the plastic holder-piece that holds the switch in place. Be careful, there is a small pin on the frame, so rotate the switch OUT toward you while lifting (carefully) the plastic holder-piece (you will see it on top of the switch). You can use an ohm meter to test the continuity of the switches. But if the buttons don't "pop" they are defective. Replace switch and reassemble.
Was this helpful?
Thank you for voting!
Handle was broken R&R required.
22 of 28 people found this instruction helpful.
  • Frank from Punta Gorda, FL
  • A Bit Difficult
  • Less than 15 mins
  • Screw drivers
Open the door and start at the outside perrimeter of the plastic moulding by inserting the putty knife and gently prying up.I started at the 2 latches that secure the door when it closes.Work your way around to the top and bottom. I was able to leave the portion of the plastic moulding by the door hinges still intact while removing the sc rews for the handle and replacing with the new one.After handle is on gently snap moulding back in place.Remember start at the inside of the door in the small opening at the outter edge of the door.
Was this helpful?
Thank you for voting!