This high-voltage diode is designed for use within various makes and models of microwaves and is a genuine OEM part that converts alternating current (AC) into direct current (DC). If you notice your ...
This is a high limit thermostat designed for use within various models of microwaves. The purpose of a high limit thermostat is to open the circuit of the appliance when the internal temperature reach...
The microwave light, or surface light lens, keeps the bulb in your microwave protected from getting cracked, scratched, and damaged. If your lens is defective or broken, or the bulb in your appliance ...
This part is the replacement flat bolt for your microwave. It is a Phillips-head screw, which is approximately 4 inches long. The main reason to replace this bolt is if your current bolt is stripped, ...
The rectifier (also known as a diode) provides the microwave with energy to cook food. If your appliance is not producing heat or not turning on it could be due to the breakdown of the rectifier. This...
This vent damper is a genuine OEM replacement part that is compatible with various models of Samsung over-the-range microwaves with ventilation systems. It is responsible for regulating the airflow in...
Removed control panel, discharged HV capacitor. Removed old diode, tested to confirm failure. Replaced part. Other than the removal of the panel swapping the part was almost as easy as replacing a light bulb.
The high voltage tired was shorted. I replaced it with a new one, but that did not solve the problem.
You can test the high voltage tired with a voltmeter and a 9 V battery. Search Search for it on YouTube.
You can also test the high voltage capacitor, the high-voltage transformer, and the magnetron with a multi met
... Read moreer. Search for the procedures on YouTube.
I tested all these high-voltage components with a low-voltage multi meter, and they all checked out OK (after replacing the diode). However the microwave still did not heat food.
When working on a microwave it is important to unplug it and also discharge the high voltage capacitor. The capacitor has a 10 megaohm resister to automatically discharge itself, but it may have failed – – so discharge it manually.