Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Broken ice maker
Unplugged faulty ice maker, removed two screws holding it to the refrigerator and took it out. Reversed the operation with the new ice maker and after a few minutes presto, we have ice.
This was the second part I tried. The defrost timer was first, but that did not fix it. To do this I had to remove the ice maker and the back plate of the freezer. Then I defrosted the coil and cut the wires. stripped them back and installed the new thermostat. re-assembled and tested. has been working great ever since.
Refrigerator would not run but interior light was on.
I unplugged the refrigerator, then opened the door and removed four screws holding the plastic electrical panel to the interior top of the main refrigerator compartment and noticed the cold control was corroded badly, apparently from moisture in the panel. I ordered a new one from partselect.com. When it arrived the next day, I then pulled off the control knob, unclipped the cold control, unplugged the three wires to the control, then removed the styrofoam insulation blocks holding the thermocouple wire and then removed the thermocouple wire to complete the removal. I then reversed the process to install the new thermostat and control. That is repositioned the thermocouple wire, put the insulation blocks back to hold the wire, then replugged the three electrical wires, clipped the control back and pushed the control knob back on and finally screwed the panel back to the top of the main compartment and plugged the refrigerator electrical cord back in to provide current to the refrigerator. It immediately started up and ran fine. Total time - about 8 minutes.
When cleaning the coils on your refrigerator always remember rule number 1, unplug it first. I was cleaning the coils and hit the fan blade while it was moving with a brush, thus breaking off one of the fan blades. I ordered a new fan and installed it in about 15 minutes. Very easy repair.
I had put in a new ice maker and it still had the problem, (I needed the Ice maker anyway) I installed the vale and while I was at it I put a five year filter on the water line that went from the value to the Ice maker, it took less than one hours, the ice is making like it did when it was new, I could not be more please at theis time. Thanks for your Interest. God bless.
Brand new refrigerator, but evaporator fan blade broken, causing considerable vibration and noise.
Really, really, really easy: 1.Unplug refrigerator (electrical safety). 2.Remove cardboard cover at bottom of refrigerator (two short self-tapping bolts) with a wrench. 3.Pull old fan blade off fan motor shaft (just held on by a compression fitting--no tools needed). 4.Push new fan blade on shaft. 5. Replace cardboard cover. 6. Plug in refrigerator, write nasty letter to Frigidaire.
Loosen two screws, unclip electrical connection, remove ice maker, remove l shaped leveling piece of metal from old one, put on new one. Install in reverse order. Hint.. when loosening two screws, use a mirror
I removed a couple of screws from the old part, and inserted the new part. Replaced the screws and I was done. No problem. I'm an almost 60 year old woman, and fixed this myself. It was so easy.
- Unsnapped old light socket from top of Frig - Disconnected elect wires - Reconnected elect wires to new light socket - Snapped new socket in place - Done in less than 2 min.
I slammed the door on the pan severely cracking it.
All I did was to take out the cracked pan and slide in the new one.Excellent service.I ordered the pan late evening one day the part arrrived not the next day but the day after.I expected that it would have taken a week or better.I recommend Part Select.com because of this.
It was fairly easy. Only had to remove the back cardboard. Remove 3 screws and the power plug. Replacing the screws took a little time the motor mount didn't seem to be tapped exactly for the screws supplied and it was in a tight area. Its working great now.
Pull refrigerator away from wall, being careful not to kink or break water line to ice maker, unplug refrigerator. Using 1/4" nutdriver, remove cardboard lower rear panel, bottom lifts out. Fan and motor are now directly in front of you, grasp the moter to stablize it, and using your other hand, pull fan hub from motor shaft. Be sure motor shaft is clean before reinstalling new fan blade, press new bladr onto motor shaft, until center of blade is centered on outlet side of fan housing. spin blade by hand to insure clearance. Plug refrigerator in and observe operation of fan, refrigerator needs to be calling for cooling for this fan to operate. Reinstall cardboard panel and move refrigerator back into position.