EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details

Find Parts

Parts Departments

Top Model Types

Top Brands

Repair Help

Expert Repair Videos

Keep typing for more specific results...

25322442412 Kenmore Freezer - Overview

Diagrams for 25322442412

See every part. Know exactly what you need.

Enter a part description. DIY Heroes keep it simple, eg. "belt" or "pump".

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Freezer Door Key – Part Number: 297147700
$14.18
In Stock
Freezer Door Key
★★★★★
★★★★★
(28)
Part #297147700
This freezer door key is designed for use with most upright and chest freezers. It is an authentic OEM replacement part. Your appliance has a lid or door that locks and unlocks, this key controls that function. If your key is lost or damaged this is the replacement you need. Be sure to store this key someplace safe, we also recommend that you store it away from the freezer. This part is made of plastic, is white in color, and it is sold individually.
DEFROST TIMER – Part Number: 5304518034
$48.93
In Stock
DEFROST TIMER
★★★★★
★★★★★
(16)
Part #5304518034
This is a 120 volt defrost timer manufactured for refrigerators. The defrost timer manages the automatic defrost systemin the unit. It acts like a clock by switching between activating the cooling cycle and the defrost heater to maintain the set thermostat temperature, preventing the unit from being too warm or cold. The defrost timer may need to be replaced if the fridge will not maintain its temperature or has frost buildup. Depending on the model, it could be located on the rear panel or ceiling of the fresh food compartment. Be sure to disconnect power to the refrigerator before replacing this part.
Run Capacitor - 120V – Part Number: 297286803
$52.75
In Stock
Run Capacitor - 120V
★★★★★
★★★★★
(18)
Part #297286803
This part helps the compressor kick on and off while maintaining a constant temperature to keep things frozen in your freezer. The run capacitor is attached to the compressor. This part is 120 volts and 15 mfd. The run capacitor helps the compressor kick on and off while maintaining a constant temperature to keep things frozen in your freezer. If your refrigerator is too warm, will not start, or your freezer section is too warm, you may need to replace this part. This is a genuine OEM part. Please remember to disconnect power to your refrigerator before starting your repair.
Evaporator Fan Motor (115v) – Part Number: 297309000
$60.64
In Stock
Evaporator Fan Motor (115v)
★★★★★
★★★★★
(10)
Part #297309000
This evaporator fan motor is 115V. If you notice that your freezer is noisy or is too warm, you may need to replace the evaporator fan motor. This package comes with the evaporator fan motor itself, as well as a wire harness. The evaporator fan motor is in the back of the freezer, so you will need to remove your freezer shelves and the back panel before you can access it. The function of the evaporator fan motor is to circulate air over the coils. The coils convert the heat into cool air, which is then circulated. Be sure to remove the power source from the freezer before you begin this repair.
Refrigerator Light Bulb – Part Number: 5304517886
$63.72
In Stock
Refrigerator Light Bulb
★★★★★
★★★★★
(10)
Part #5304517886
This is an LED light for a variety of refrigerator models. This 3.8W LED light is used to shine and adequately light the contents of your refrigerator when you open its door. If your current light is significantly dimmer than normal, or simply not working anymore, it will need to be replaced. To replace this bulb, unplug your fridge momentarily, and then simply unthread the old one and screw in the new one. This bulb is sold individually and does not come with any other parts.
Adjustable Leveling Foot - Black – Part Number: 216396900
$39.94
Special Order
Adjustable Leveling Foot - Black
Part #216396900
This part could be found underneath a fridge, dryer, or freezer. The original foot may be cracked, broken, or perhaps missing altogether. If you notice the appliance is uneven to the floor or wobbling, it may indicate that the levelling foot needs to be replaced. You will need pliers and a block of wood to perform this task. There will be one adjustable foot found in the package. Lift the dryer and place the wood to keep it propped up. You may need to use the pliers to remove the old foot. Screw the new foot into place using your hand. Once the new leveling foot is in place, lift the appliance and remove the block. Test the machine out to ensure it is now sitting level.
Hinge Mounting Hexagonal Screw – Part Number: 240578902
$26.35
In Stock
Hinge Mounting Hexagonal Screw
Part #240578902
This genuine OEM hinge mounting screw is designed for use in Frigidaire and Electrolux refrigerators, providing a secure and reliable way to fasten door hinges to the cabinet. Built with a durable hex washer head and standard threading, it helps restore proper door alignment and maintain a tight seal to prevent cold air loss. Ideal for replacing worn, stripped, or corroded hardware, this heavy-duty screw ensures long-lasting stability and dependable everyday performance.
Hinge Bearing – Part Number: 5304511026
$18.60
In Stock
Hinge Bearing
★★★★★
★★★★★
(15)
Part #5304511026
This part is sold individually.
SWITCH – Part Number: 216822900
$69.59
In Stock
SWITCH
★★★★★
★★★★★
(6)
Part #216822900
This part turns the light on/off as the door opens and closes.
SCREW – Part Number: 216858001
$19.68
In Stock
SCREW
Part #216858001
Sold Individually.
Door Closing Cam – Part Number: 297415900
$21.86
In Stock
Door Closing Cam
★★★★★
★★★★★
(3)
Part #297415900
Sold individually.
Top Hinge Bearing – Part Number: 216970802
$19.68
In Stock
Top Hinge Bearing
Part #216970802
This hinge bearing supports smooth door movement while maintaining proper alignment. Reduced friction helps prevent wear and ensures easy opening and closing. Replacing a worn bearing restores smooth and stable door operation.

Questions And Answers for 25322442412

Ask our experts a question about this model and we'll get back to you as soon as possible!

Sort by:
  • 1
  • 2
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Gregory - For model number 25322442412
February 28, 2023
how do I replace the freezer light bulb
Chris Boyle Profile
Hi Gregory, thank you for contacting us. We have attached the relevant video for the installation of a freezer bulb. We hope this sorts out your problem!
3 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Frank - For model number 25322442412
June 1, 2023
Freezer wont star or stop automatically by will run manually
Chris Boyle Profile
Hi Frank, thank you for reaching out. Based on the description that you have provided, we would recommend checking the temperature control thermostat, part number PS12365300, as it is most likely faulty and may need to be replaced. We hope this solves your problem!
$68.10
In Stock
Temperature Control Thermostat
1 person found this instruction helpful.
Was this helpful?
Thank you for voting!
Jan - For model number 25322442412
June 28, 2021
Is it normal to have a some amount of water drainage on the floor during the summer? It evaporates quickly. Our unit is in our garage.
Chris Boyle Profile
Hello Jan, Thank you for the question. There should be no water drainage on the floor. We suggest checking the Drain Tube for a blockage or damage. We hope this helps!
$23.01
Special Order
DRAIN HOSE
Was this helpful?
Thank you for voting!
Robin - For model number 25322442412
February 19, 2022
My mom had just bought this freezer and it worked fine in her house. We moved to my house after it had been unplugged for several months. It is getting power but will not turn on now.
Chris Boyle Profile
Hello Robin, Thank you for the question. We suggest testing the Run Capacitor. This part helps the compressor kick on and off while maintaining a constant temperature to keep things frozen in your freezer. The run capacitor is attached to the compressor. When testing a capacitor with a multimeter, you will need to set the meter between 10K and 1m ohms. Touch the leads from the multimeter to the corresponding leads on the capacitor. The red lead to positive and the black lead to the negative. The meter should start at zero and then moving slowly toward infinity. This means that the capacitor is in working condition. If the meter stays at zero, the capacitor is not charging through the battery of the meter, meaning it is not working. If you need help placing an order, customer service is open 7 days a week. Please feel free to give us a call. We look forward to hearing from you!
$52.75
In Stock
Run Capacitor - 120V
Was this helpful?
Thank you for voting!
Ha - For model number 25322442412
April 6, 2023
Hi there . Why my Kenmore freezer run all the times . The door s good no gap at all inside cold. Look like thermostat not working. Thank you
Chris Boyle Profile
Hi Ha, thank you for reaching out. Based on the description that you have provided, we would recommend that you first make sure the room temperature is suitable for the freezer to operate. Normal operating room temperatures for a freezer are between 60° and 95° Fahrenheit. The hotter and more humid the air is, the less efficient the freezer will be, causing it to run more. If the room temperature is fine, then the issue is most likely due to the defrost timer, part number PS12585793, which may need to be replaced. We hope this helps!
$48.93
In Stock
DEFROST TIMER
Was this helpful?
Thank you for voting!
  • 1
  • 2

Common Symptoms of the 25322442412

How this model fails, and the parts that fix it.

Watch our pros, then fix it yourself.

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
After getting wiring diagram off internet it was diagnosed as freezer stuck in defrost mode, temp alarm on, but fan running.
82 of 99 people found this instruction helpful.
  • James from Navarre, FL
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
Turned gray knob on defrost timer (located bottom left back of freezer) past defrost position to verify compressor would run...it would not, but fan would run. Tested run capacitor...found borderline defective (weak, wrong value ohm meter kick). Just to be sure, removed interior shelves and interior rear and gasket to check heater at 20 ohms as OK and removed thermostat and verified contact closure after exposure in another freezer....re-installed, hooked heater back up and re-installed interior rear panel. Replaced defrost timer by unplugging 4-pin connector, then removed 2 screws that hold it to the bracket. Installed new one in reverse order. Then removed wire bail holding run capacitor to compressor plug assembly, removed run capacitor, plugged in new one. Turned on freezer......now making ice and holding cold temperature and cycling properly between freeze and defrost modes. Two problems made this repair a bit more difficult. This is the second time that defrost timer has failed...only got 3 years from last one.
Was this helpful?
Thank you for voting!
replacement freezer keys
77 of 91 people found this instruction helpful.
  • CHARLOTTE from SEDALIA, MO
  • Really Easy
  • 30 - 60 mins
I accidently threw away both freezer keys to our upright Gibson and G.E. Freezers!!!! I had no luck finding replacements locally, so I got on the internet and came across PartSelect.com. I called them on the telephone; and after giving the model numbers of my freezers, the keys were on their way!! I received the keys very quickly and bot h worked perfectly. I would highly recommend Partselect.com. Charlotte M. Bishop
Was this helpful?
Thank you for voting!
Temp alarm sounding and food on top shelves partially thawed
43 of 52 people found this instruction helpful.
  • Wayne from Forest Hill, MD
  • Easy
  • Less than 15 mins
  • Screw drivers
After silencing the alarm, it seemed to be running as normal without any unusual noises, but food was starting to thaw from the top shelf on down and condensation was dripping from the roof. We were able to place most of the food in 2 large ice chests and then the rest in the freezer compartments of 2 fridges we have in the house. I the n turned down the temp dial to the coldest setting and let it run for an hour or so; no change.

After researching on the internet, it sounded like our symptoms could be pointing to a defrost timer issue. I pulled the freezer away from the wall, located the timer and used a large screwdriver to slowly advance it. While doing this, at one point I could hear the compressor kick in. I pushed the quick freeze button and let it run for a while. When I checked it in a few hours, the alarm light had gone out and water that I had placed inside was frozen. We took a chance and put the food we placed in the ice chests back in the freezer. Everything was fine several hours later.

I ordered a new defrost timer, it arrived in a couple of days, and replaced the old one with it in a matter of minutes by disconnecting the wire harness from the old timer, removing the 2 screws holding it onto the bracket, screwing the new timer to the bracket, reconnecting the wires harness, and done. It's been a week or so and no problems.
Was this helpful?
Thank you for voting!