The evaporator is found in the back of the freezer. This kit comes with two mounting grommets, two sleeves (not to be used on porcelain models), two #8 mounting screws, and a push-on fan blade. If you are experiencing symptoms such as the fridge making loud noises (generally stemming from the freezer compartment), or the fridge/freezer fe...Read moreeling warm in temperature, this may indicate a need to replace your evaporator fan motor. This part pulls air into the evaporator coils and then disperses the air in a continuous motion throughout the refrigerator and freezer.
NOTE: NO LONGER ABLE TO GET BRACKETS. SEE PART INSTRUCTIONS IN SERVICE MATTERS INSTRUCT SHEET# W11500157 11/20KC.
This refrigerator evaporator fan motor kit comes with a wiring harness and a four-inch push on fan blade. If your current evaporator fan motor has shorted out and does not circulate the cold air from the freezer into the fresh food compartment, or you notice that your refrigerator is too warm, you may have to replace the evaporator fan. T...Read morehe evaporator fan motor is located behind the back panel of your freezer. You will need to remove any shelves, as well as the back panel to access this part for repair. Be sure to disconnect the power source from the refrigerator before you begin this repair.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Unit very noisy and freezer too warm
90 of 96 peoplefound this instruction helpful.
Michael from Churchville, NY
Easy
15 - 30 mins
Nutdriver, Screw drivers
First I removed the racks in the freezer. The rack supports on the sides lift off without tools. The evaporator cover is at the back of the freezer. 4 phillips head screws. The cover lifts up then forward to expose the evaporator, evaporator fan and duct. The duct is held by 3 hex head screws. The evaporator fan is attached to the duct wi
... Read moreth a wiring pigtail to a plug. Unplug the fan and remove the duct. The fan is held by 2 hexhead screws. The new fan is put in place and assembly is simply the reverse of disassembly. The unit is quiet and cools properly now. The new part fit perfectly.
Read less
Was this helpful?
Thank you for voting!
fan motor was loud,sqeal,would not get cold
35 of 42 peoplefound this instruction helpful.
Thomas from Monsey, NY
Easy
15 - 30 mins
Pliers, Screw drivers
Very easy, hardest part was taking panels out of way. 20 min. to finish. After repair it works like new.About 20 years old.
Was this helpful?
Thank you for voting!
Evaporator Fan had quit running
25 of 28 peoplefound this instruction helpful.
Duane from Piper City, IL
Really Easy
Less than 15 mins
Nutdriver, Screw drivers
After unplugging the fridge, I removed all the phillips head screws from the evaporator fan housing as well as the back cover and the bottom of the freezer compartment (7) in all. After first removing the bottom cover - then the back cover I could access the evaporator fan unit. This was held in place with two hex-head screws that were e
... Read moreasily removed with a nut driver. Then after unplugging the Red, White, and Green wires from the fan I removed it and replaced it with the new one. I did have to break off the two ends of the mounting bracket as described in the instruction sheet since it was too wide. Repeating the above steps in reverse, I had the job done and refridgerator up and running as quiet as could be in less than 15 minutes.