water was leaking down from freezer section to bottom part of unit
13 of 16 people
found this instruction helpful.
-
Eric from miami, FL
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
First, unplugged the refrigerator. Then removed bottom plastic liner of the freezer, 2 screws with 5/16 nut driver. At this point the ice maker had to be removed 3 screws, two on the upper part and the other under the ice maker. Now the back wall of the freezer section was removed by unscrewing 2 screws with the nut driver. This gave me a
... Read more
ccess to remove the defective clip-on Bimetal defrost thermostat. It was located in the upper right corner on the back wall of the freezer. Cut off the 2 wires from the bad part( one pink the other brown)then used wire nut to replace with the new part and matched wires from freezer to new part( pink to pink and brown to brown) and clipped the part in one section of the coil. ( where the bad part was located) Put all back in place. And so far no more water leak inside the fridge.
Read less
Was this helpful?
Thank you for voting!
Leaking water inlet valve
14 of 19 people
found this instruction helpful.
-
Steven S. from Kerrville, TX
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Wrench (Adjustable)
This would have been a less-than-5-minute repair except for one item. The water intake nossle was 180 degrees from the original part. As a result, the copper water inlet tube would not fit in the old space and still allow me to reattach the valve to the freezer chassie. I ended up leaving the valve hanging loose under the freezer. I s
... Read more
pent most of my time trying to fit the valve into the old space.
Unplug freezer. Disconnect electrical connections (pull apart). Remove one screw holding the valve to the chassie. disconnect water inlet pipe and water outlet pipe from old valve.
Reconnect electrical connection to new valve. Reconnect in and out water hoses. Reconnect valve to chassie. Plug freezer back in. Finished
Everything works just fine !
Unplug freezer. Disconnect electrical connections (pull apart). Remove one screw holding the valve to the chassie. disconnect water inlet pipe and water outlet pipe from old valve.
Reconnect electrical connection to new valve. Reconnect in and out water hoses. Reconnect valve to chassie. Plug freezer back in. Finished
Everything works just fine !
Read less
Was this helpful?
Thank you for voting!
Freezer compartment iced over, food thawing,
12 of 13 people
found this instruction helpful.
-
Lawrence from New Bern, NC
- Easy
- Less than 15 mins
-
Nutdriver
I deenergized the refigerator, removed the storage tray, three screws that hold the ice maker, two screws that hold the lower portion of the freezer, two screws tjhat hold the back portion of the freezer. Removed the ice maker and disconnected the wire connector and ground, Removed lower portion of the freezer which allowed the back porti
... Read more
on to be lifted out. Once the back was out the bimetal defrost thermostat was located in the upper right corner clipped to a copper line. Using an ohm meter, I found the bimetal defrost thermostat to be electrically open, ordered part from information found on part, Once part arrived I deenergized the refrigerator and replaced bimetal thermostat by cutting the old thermostat wires (pink and brown), stripping the wires back about 5/8 inch and wire nutting the replacement parts like colored wires, clipped the bimetal part on the copper tube, replaced the covers in reverse order, and reenergized the refrigerator. Testing and replacing the part took about 15 minutes, waiting for the ice build up to thaw took considerably longer.
Read less
Was this helpful?
Thank you for voting!
No water to the ice maker
11 of 13 people
found this instruction helpful.
-
Ron from Ferndale, WA
- Really Easy
- 15 - 30 mins
-
Nutdriver
At age 65 I have never attempted to repair a refrigerator, until now. It took longer than needed because I did not read these articles carefully. Please note that when you open the door and the light blinks twice, waits a second and blinks again, the optics are working fine. I ordered an emitter and receiver when I didn't need to. I s
... Read more
ent it back, the money was refunded, and ordered the ice maker. I replaced the old icemaker by removing three screws and slipping it out of its holder.
Here is how I found out I needed the new ice maker. I took the supply line apart that runs down the back of the refrigerator. I blew through it without any trouble. This told me that the line was not frozen within the refrigerator. I put the supply line back together, and jumped the solenoid that was connected to the supply line at the bottom right of the refrigerator. My model is the side by side, so it has two solenoids. The solenoid that runs the water to the dispenser in the door was always running, so I knew if there was a problem it would be with the ice maker solenoid. So, how did I jump the solenoid. Kids, don't try this at home. I disconnected the wiring harness to the solenoid by pulling it straight out. Then I took the female end of an extension chord and placed a twelve two electrical wire with the ends stripped into the positive and negative slots. I then jumped the solenoid. Water ran to the ice maker, but there still wasn't any ice made. Since the optics and the solenoid were working it seemed to me that the ice maker wasn't doing it's part. There are easier ways to check the solenoid in this forum, but this worked for me. I saved a lot of money and the parts got here quickly.
Here is how I found out I needed the new ice maker. I took the supply line apart that runs down the back of the refrigerator. I blew through it without any trouble. This told me that the line was not frozen within the refrigerator. I put the supply line back together, and jumped the solenoid that was connected to the supply line at the bottom right of the refrigerator. My model is the side by side, so it has two solenoids. The solenoid that runs the water to the dispenser in the door was always running, so I knew if there was a problem it would be with the ice maker solenoid. So, how did I jump the solenoid. Kids, don't try this at home. I disconnected the wiring harness to the solenoid by pulling it straight out. Then I took the female end of an extension chord and placed a twelve two electrical wire with the ends stripped into the positive and negative slots. I then jumped the solenoid. Water ran to the ice maker, but there still wasn't any ice made. Since the optics and the solenoid were working it seemed to me that the ice maker wasn't doing it's part. There are easier ways to check the solenoid in this forum, but this worked for me. I saved a lot of money and the parts got here quickly.
Read less
Was this helpful?
Thank you for voting!
Broken gooseneck on fill tube
10 of 11 people
found this instruction helpful.
-
Thomas from Brunswick, OH
- Really Easy
- 15 - 30 mins
-
Screw drivers
The gooseneck on the icemaker fill tube extends out beyond the back cabinet of the refrigerator, and is easily broken. Luckily, this part is a piece of cake to replace. You'll literally spend more time pulling out your fridge and cleaning out behind it then you will replacing this part.
Shut off water supply line, and turn of ... Read more f ice maker (lift the metal bar in the ice bucket all the way up). Loosen the hose fitting, and remove two screws. Pull out the old tube, and slide the new one in. You may have to wiggle the tube around from the inside to get the alignment correct. Replace screws and fitting. Turn water and ice maker back on, and check for leaks. It really is that easy! It took me longer to type this than to actually replace the part.
Only one potential catch. The instructions warn that you may have to cut the new tube to match the length of the old tube, so make sure you compare the length of the old and new tube. I didn't have to to do anything - the replacement part was the exact same length of the original. If by chance you do need to cut the tube, you'll need small saw of some sort, such as a coping or hack saw.
Shut off water supply line, and turn of ... Read more f ice maker (lift the metal bar in the ice bucket all the way up). Loosen the hose fitting, and remove two screws. Pull out the old tube, and slide the new one in. You may have to wiggle the tube around from the inside to get the alignment correct. Replace screws and fitting. Turn water and ice maker back on, and check for leaks. It really is that easy! It took me longer to type this than to actually replace the part.
Only one potential catch. The instructions warn that you may have to cut the new tube to match the length of the old tube, so make sure you compare the length of the old and new tube. I didn't have to to do anything - the replacement part was the exact same length of the original. If by chance you do need to cut the tube, you'll need small saw of some sort, such as a coping or hack saw.
Read less
Was this helpful?
Thank you for voting!
Crisper Drawer cover broke.
10 of 11 people
found this instruction helpful.
-
Monica from Greendale, WI
- Really Easy
- 15 - 30 mins
-
Screw drivers
We removed the drawers and drawer cover
(after we'd unloaded that part of the refrigerator!), and
took the glass out of the drawer cover. Then we took
the gaskets off the old cover and put them on the new
one (that's what the screwdriver was for).
It was easy because of the very helpful diagram of all
t ... Read more he parts that I had used on the web site to order the
part.
Getting the part was amazingly fast - thank you!
(after we'd unloaded that part of the refrigerator!), and
took the glass out of the drawer cover. Then we took
the gaskets off the old cover and put them on the new
one (that's what the screwdriver was for).
It was easy because of the very helpful diagram of all
t ... Read more he parts that I had used on the web site to order the
part.
Getting the part was amazingly fast - thank you!
Read less
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people
found this instruction helpful.
-
Benjamin from Daytona Beach, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
Read less
Was this helpful?
Thank you for voting!
Ice maker stopped working
9 of 9 people
found this instruction helpful.
-
Martin from DESOTO, TX
- Really Easy
- 30 - 60 mins
-
Nutdriver
Our ice maker had been overfilling and causing a big block of ice in the bin for some time, but it finally stopped working completely. In trying to determine the problem, I read the comments on the PartSelect website from other customers and thought I needed either a new valve or a new ice maker. I replaced both because when I took the
... Read more
old ice maker out, it had a lot of mineral deposits in it and looked very unappetizing. The videos on how to replace the valve and ice maker were very helpful. Other customers comments on replacing the valve were also great. The only thing I would add is that after getting the parts installed and the water line and electricity reconnected, it takes an hour or so for the ice maker to to fill. I suppose there is a temperature sensor that won't fill it until gets down to a certain point. I am very pleased with the outcome of this project on our 28 year old refrigerator.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people
found this instruction helpful.
-
Steven from Brigham City, UT
- Really Easy
- 15 - 30 mins
-
Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Read less
Was this helpful?
Thank you for voting!
socket melted with bulb in it.
12 of 18 people
found this instruction helpful.
-
martin l. from JACKSONVILLE,, IL
- Really Easy
- Less than 15 mins
plastic warped in ,spaced out and, the socket snapped back in place.
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people
found this instruction helpful.
-
JAMES from Middleboro, MA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Read less
Was this helpful?
Thank you for voting!
part of a freezer support bracket was missing
9 of 10 people
found this instruction helpful.
-
peter from saint augustine, FL
- Really Easy
- Less than 15 mins
I wasn't sure the kit included the part I needed from the pictures, but it did. The part slipped over the flat plastic bracket attached to the right freezer wall and the shelf fit over it. No tools required.
Was this helpful?
Thank you for voting!
The refrigerator leaked water every time the ice maker filled.
11 of 16 people
found this instruction helpful.
-
Robert E. from Darien, IL
- A Bit Difficult
- Less than 15 mins
The problem was discovered to be a cracked fill tube head, This part extends behind the refigerator and is VERY vulnerable to breakage when the box is pushed backagainst a wall space! Placing a shim under the vertical part of the fill tube fixed the problem even without replacing it with the new part. So, now I have a spare!
Was this helpful?
Thank you for voting!
ice maker was leaking water
13 of 22 people
found this instruction helpful.
-
Sandra from Temecula, CA
- Really Easy
- 15 - 30 mins
-
Screw drivers
Parts went right into place as the pictures showed and was working again in about 30 minutes. The only thing that wasn't working was the ice took forever to make, but solved that problem by turning up the temp in the freezer.
Other Parts Used:
Was this helpful?
Thank you for voting!
fan had stopped-freezer not performing etc.
8 of 8 people
found this instruction helpful.
-
George from Glenwood, MN
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws
... Read more
and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Read less
Was this helpful?