Models > FHC10CM

FHC10CM General Electric Freezer - Overview

Sections of the FHC10CM

[Viewing 1 of 1]
Keep searches simple, eg. "belt" or "pump".
Relay PTCR - 3 Wire – Part Number: WR07X10055
Relay PTCR - 3 Wire
★★★★★
★★★★★
(3)
PartSelect #: PS963826
Manufacturer #: WR07X10055
Also known as the Start Relay. The start relay briefly boosts the compressor, and then shuts off as soon as the motor gets up to speed.
$28.62
  In Stock
LAMP – Part Number: PURCH LOC
LAMP
PartSelect #: PS711095
Manufacturer #: PURCH LOC
  No Longer Available
LOCK COMPLETE – Part Number: 3-26329-023
LOCK COMPLETE
PartSelect #: PS12310493
Manufacturer #: 3-26329-023
  No Longer Available
DRIER 1" WITH VALVE – Part Number: WG03F02140
DRIER 1" WITH VALVE
PartSelect #: PS12341198
Manufacturer #: WG03F02140
  No Longer Available
LAMP - 15T7N – Part Number: WG04F07592
LAMP - 15T7N
PartSelect #: PS9863512
Manufacturer #: WG04F07592
  No Longer Available
NO LONGER AVAILABLE – Part Number: 4-32812-012
NO LONGER AVAILABLE
PartSelect #: PS12324349
Manufacturer #: 4-32812-012
  No Longer Available
TIEBOLT HINGE – Part Number: 2-30037
TIEBOLT HINGE
PartSelect #: PS12309903
Manufacturer #: 2-30037
  No Longer Available
NO LONGER AVAILABLE – Part Number: 1-26356
NO LONGER AVAILABLE
PartSelect #: PS12310835
Manufacturer #: 1-26356
  No Longer Available
NO LONGER AVAILABLE – Part Number: 4-33521-001
NO LONGER AVAILABLE
PartSelect #: PS12311610
Manufacturer #: 4-33521-001
  No Longer Available
CLIP COVER – Part Number: 4-34047-001
CLIP COVER
PartSelect #: PS12317704
Manufacturer #: 4-34047-001
  No Longer Available
Grommet, hinge (plastic) – Part Number: 3-23995-002
Grommet, hinge (plastic)
PartSelect #: PS12318402
Manufacturer #: 3-23995-002
  No Longer Available
NO LONGER AVAILABLE – Part Number: 1-30228-002
NO LONGER AVAILABLE
PartSelect #: PS12322746
Manufacturer #: 1-30228-002
  No Longer Available

Questions And Answers for FHC10CM

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Common Symptoms of the FHC10CM

[Viewing 1 of 1]
Will Not Start
Fixed by
these parts
Fixing
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Relay
Removed back panel. Opened cover to relay attached to the compressor and pulled off replacing with new relay. No problem.

Better than paying $250 for someone else to do it.
Parts Used:
Relay PTCR - 3 Wire
  • John H from Austin, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
41 of 52 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!