This is a multi-use and multi-appliance screw. It can be used on a microwave, refrigerator, range/oven, air conditioner, dehumidifier, washer, or dryer. The measurements of this screw are 8 x 1/2 inch. It has 6 threads. Refer to the manual provided by the manufacturer for further information on repair and accurate guidance. Remember to wear work gloves as a safety precaution.
This part is both the start relay and the overload. The start relay boosts the compressor, and then shuts off as soon as the motor gets up to speed and the overload provides extra protection against excessive temperatures.
This metal freezer door key fits upright freezers. It has a cross shape and is approximately 2 inches long. If your freezer door will not stay shut, you can lock the door to keep it closed. If your key will not lock, or unlock the freezer door; check to see if it has been damaged or bent. If the key is damaged, you should look to replace ...Read moreit to avoid damaging the lock. The key should engage the locking mechanism with ease. If the lock sticks when you turn the key, use penetrating fluid to loosen the mechanism. These keys are sold individually, and should be stored somewhere safe and not next to the unit.
This drier may also be known as a refrigerator ultra-violet dye drier or a filter drier and is meant to be used with your fridge. This piece is a filter for the refrigerant that moves through the refrigerators sealed-system. The most common reason you will need to replace the filter is if your fridge/freezer is not starting. You should co...Read morensider having this piece installed by an appliance repair technician that is trained and licensed. Installing this part requires specialized knowledge and tools. The installation will require the service technician to recover and recharge the refrigerant in the refrigerators sealed-system.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Our Refrigerator and freezer stopped working
60 of 71 peoplefound this instruction helpful.
Anna from Lincoln, RI
Easy
Less than 15 mins
Screw drivers
I had read on a fix it site that the start device for the compressor on this particular model was known to fail after 3-5 years. When we received the part it looked like something that just plugged into the compressor. My husband unscrewed the panel in the back of the fridge and saw the part on the compressor. He first removed the thre
... Read moree wires that it was connected to, and the wires were inside a plug so all he had to do was remove the plug from the start device. He then removed the old start device from the compressor. Plugged in the wire plug into the new start device, and pushed in the new start device into the compressor. There was also another black part plugged into the old start device that he plugged inot the new start device that connected to the compressor. Our freezer and refrigerator starting working. Within a couple of hours our freezer had made ice.
Read less
Was this helpful?
Thank you for voting!
Refrigerator not cooling, water dripping from doors
21 of 24 peoplefound this instruction helpful.
Darrell from Hammond, LA
Easy
15 - 30 mins
Screw drivers
Water was dripping out of top freezer door and had water under the refridgerator. I could hear a clicking noice from bottom of refrigerator every 3-5 minutes. After removing back panel, I noticed the fan was running and the clicking seemed to be coming from somewhere around the compressor which was warm. I noticed on the site a si
... Read moremular problem had been submitted. It said to remove the start relay and if it rattled it was bad. I removed two wires from it ( it is connected onto the side of the compressor) then took a small screw driver to pry it away from the compressor. It not only rattled but had tiny pieces falling out. I ordered the part and replaced it in less than 15 minutes total and all is well.
Read less
Was this helpful?
Thank you for voting!
stopped cooling,the compressor would come on and shut back off.
16 of 19 peoplefound this instruction helpful.
william from shady dale, GA
Easy
15 - 30 mins
Screw drivers
pull the fridge out away from the wall and hope you have a long flex water supply hose.remove cardboard cover,oh yea unplug fridge first.unplug wire from the relay.flip the wire retainer off the relay and pry it away from the compressor.pull the 2 prong capacitor off and then reverse the steps to reasemble. skip the middle man at the loc
... Read moreal appliance shop.i waited 2 weeks for him to get the part and gave up.your reg shipping got it here in 2 days.