Quit making ice.

  • Customer: Joe from Brentwood TN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 20 of 22 people found this instruction helpful
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.

Other than the two-screw problem, it was easy.

Drawer Slide Rails were broken

  • Customer: Mikki from Tooele UT
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 19 of 20 people found this instruction helpful
For the past 6 months I've dreaded trying to find the parts and make the needed repairs to the slide rails. I just didn't have time to search for part numbers and drag all the tools out. I even contemplated buying a new frig. I thought I would have to find the original "Owners Manual". How stupid was I?

Within 15 minutes the model number was determined and the parts (VERY EASY to find the exact part) were ordered. They arrived within a week (in a GE wrapper). I unscrewed two parts per rail and within minutes the repairs were done. It took me a lot longer to clean and wipe down everything to make the refrigerator look like new again. I bragged to all my friends (like I was some type of engineer) and have referred this website to many of them. What a fantastic experience. I saved over $1,200 and the hassle of moving a frig in and out of the house. Glad you're in business and on the web.

Fridge would not stay cold

  • Customer: Juan from Brooklyn NY
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 20 of 23 people found this instruction helpful
The appliance is relatively old. Sears estimated the cost around $300 dollars after diagnosing a thermostat problem. Looked online for model and part number and found Partselect.com. Good reputation on BBB. Site was very easy to use, good customer service and quick delivery.

Replacement was easy. Temp control and timer located inside the appliance. Removed temp knob, plastic cover, light bulb and 1 screw to dislodge housing and unplug power. 4 screws to remove temp control unit and timer from metal housing. Took images before disconnecting connectors.

Replaced parts, plugged power and re-screwed onto housing. Put back the housing, bulb, plastic cover and knob.

Plugged in the appliance and turn on the temp control. NOTE: defrost timer needs to be adjusted with flathead to enable the appliance. Once the timer was enabled, unit is functioning normally.

Saved myself $200.

low flowing water (not just a drip) from refrigerator ice maker

  • Customer: Theresa from Rochester MI
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers, Wrench(Adjustable)
  • 20 of 25 people found this instruction helpful
The icemaker's valve is easy to inspect and test. First, gently pull the refrigerator away from the wall, and unplug it. Turn off the water supply to the icemaker by closing the shut-off valve in the copper waterline leading to the valve. Use a screwdriver or nutdriver to remove the rear lower access panel from the refrigerator's back.

Next, remove the fill tubing from the water valve. Use a wrench to loosen the flare nut on the brass fitting on the inlet side of the valve (above). Place a container or towel under the valve to catch the small amount of water that will spill from the valve and tubing.

Now use a screwdriver or a nutdriver to remove the screw holding the valve's mounting bracket to the refrigerator cabinet. Pull the valve out of the compartment and remove the tube (or tubes if both water dispenser & ice maker) on the valve's outlet. If plastic tubes don't come out with pliers and assuming there is enough extra tubing, then cut the plastic tubing with a even straight cut edge razor. Then, remove the solenoid's electrical contacts.

Push the plastic water and ice tubes int he appropriate holes in the new valve outlet, reconnect solenoids and remount new water valve.

Before installing the back panel on the refrigerator cabinet, test run the icemaker. Look for leaks, and tighten any leaky connections. If necessary, use Teflon tape or a similar product to ensure tight connections. Discard the first ice cubes that are produced because they are likely to have sediment in them.

Ice maker dispensed crushed ice but not cubes

  • Customer: James from Greenville NC
  • Difficulty: Difficult
  • Time to Complete: More than 2 hours
  • Tools Required: Nutdriver, Screw drivers
  • 20 of 26 people found this instruction helpful
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap out neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.

The selector switch to select water - crushed ice - or cubes broke off

  • Customer: Christopher from No. Massapequa NY
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 19 of 24 people found this instruction helpful
Removed the face plate this just gets popped off. removed the four screws to release the unit. unplugged the wiring harness, removed the two screws that hold the bracket in place that the control unit is housed in. Slid the old unit out and replaced with the new unit. installed the bracket over the control unit put two screws back, plugged the wiring harness's back in. Slid the whole unit back in replaced the four screws and put the face plate back on. Very Easy.

ice maker leaked water slowly and froze the cubes together

  • Customer: Steven from Cave Creek AZ
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
  • 21 of 30 people found this instruction helpful
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.

Door closing cam had disentigrated over the past 12 years.

  • Customer: Randall from Ashburn VA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 17 of 19 people found this instruction helpful
I read over the other posts here and went with jacking up the fridge door and setting it on (2) 2x4 studs. A nut driver was used to remove the bottom hinge. I then drilled out the rivet that held the old cam in place and then used a 3/16 rivet to secure the new cam. A rivet is not necessary as you can also use a nut and bolt to hold the cam in place. It took less time to order the part and install it than it did to drive over to the appliance parts store and pick it up. I ordered around 10 am and the part was here the next day at 2:00 (without special delivery costs). By 2:30 it was on my fridge.

This seems to be a design problem because I have to replace this part about every other year since we bought it. I tried to talk to GE but all they want to do is send a service man out to replace the part for about 100.00, But I do it for around 15.00. I just think they should find out why the rubbe

  • Customer: Jeff from Columbia City IN
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 17 of 19 people found this instruction helpful
The repair is easy, just pop the grill off around the ice and water door, then there are 4 screwws to take out so the touch pad can be moved out of the way to unsnap the old door assm. and snap in the new one and wait about a year and a hald to order another one!!!!!

Door wouldn't stay closed & was out of alignment

  • Customer: Patsy S from Ahoskie NC
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Socket set
  • 16 of 18 people found this instruction helpful
Order 2 cams as recommended in other posts.
I didn't realize until the project was finished that the 2 cams fit together to tilt the door toward the refrigerator and force the door to catch.
1. Removed all items from door storage.
2. Removed top hinge cover held by single screw and top hinge plate held by two bolts.
3. Lifted up door to clear bottom hinge pin and removed door.
4. Turned door upside down and removed bottom hinge assembly held on by two bolts.
5. Replaced upper cam located on bottom of door and screwed the hinge assembly back on to bottom of door.
6. Drilled out the rivet that holds the lower cam to the bottom hinge pin.
7. Removed old lower cam and and replaced with new cam and secured to lower hinge assembly with pan head screw and nut (instead of rivet).
NOTE: The metal shim that goes between the cam riser & door was also broken, we used a small washer instead of the replacement shim.
8. Replaced door back onto lower hinge pin and secured upper hinge pin with original bolts.
9. Placed cover on upper hinge assembly and secured with original screw.
This is a project my husband and I completed together :)
Perhaps we will store lighter items on the door to lessen the chances of the cams deteriorating again.

Wouldn't dispense ice

  • Customer: george from palmetto FL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 17 of 24 people found this instruction helpful
First pried off front panel, then removed 4 screws that hold dispensing unit in place, then rotated top of dispensing unit out, then pulled off electrical connector, then removed screw that holds switch in place and removed switch. Installed new switch by reversing above procedure. Only thing switch wasn't the problem. No ice problem was resolved later by replacing control printed circuit board which is located in the same area.

Freezer wasn't keeping food frozen

  • Customer: Alok from Alpharetta GA
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 14 of 15 people found this instruction helpful
First I turned the freezer off and took out all of the shelves in the freezer section. I then removed the guides that the shelves go into. I removed these only from one side of the freezer - the left side actually. Now I removed the plastic piece that keeps the bulb in the freezer protected. Removed the bulb. Removed the three screws on the top and the two in the bottom that keep the rear panel of the freezer attached. This exposed the header cable and the coils. The coils had ice on the lower section, I used a hair dryer to melt the ice. Removed the cable assembly that has the two heater elements and the thermostat. The thermostat had to be plucked off the the metal pipe of coils. Replaced the assembly with the purchased assembly. Clipped the thermostat onto the metal pipe of the coils. COnnected the wires at the white connector. Attached the real panel using the five screws, put the bulb back in, installed the bulb cover, installed the shelf guides, put the shelves back in.

Freezer freezes very well now.

The old Solenoid was rusted and made a loud noise, also kept the trap door open.

  • Customer: Kevin from West Palm Beach FL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 15 of 18 people found this instruction helpful
First I removed the face plate by lightly prying . Once removed noticed 4 screws. Removing the screws allows you to gain access to the two plugs, one for the solenoid and the other for the switch that energizes the solenoid . Unplug the connectors and carefully lower the piece enough to reach the 3 screws that hold the solenoid in place. The 4th screw in the center at the bottom of the solenoid is the ground wire. If it is rusted like mine was just re-attatch it to one of the solenoids holding screw. It must be grounded!
Just re-assemble, just dont forget to replug the connectors. Also a little hint, If you open the freezer door a little you wont trigger the solenoid.

Kickplate grille cracked

  • Customer: John from Georgtown TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 14 of 15 people found this instruction helpful
Pulled off cracked grille and inserted new in grille holders

WATER LEAK FROM THE ICE MAKE - WATER ALL OVER THE FRIG

  • Customer: David T from Irvine CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench(Adjustable)
  • 13 of 14 people found this instruction helpful
REPLACE THE OLD WATER VALVE (WR57X11) with the new one (WR57X10051:
Make sure you unplug the 110 AC power . and close the water come to the refrig. first

1. Open the paper panel on the back with screw driver.
2 Use a small adj. wrench to take the old valve of.
3. Label the connector and its terminals in a proper number to Identify their connector.
4. unscrew 2 water hoses - one to the drinking one to the Ice maker. They are in diff. sizes - make sure to mark where the hoses connected in case you need to use it again.
5. Cut of the thread section on the hose end - you do not need thread any more on the new water valve.
6. Make sure the new valve is in the same position as the old one. then plug the water hoses to the valve - and connector terminals. There are 2 new terminal adapter in your new package. These new adapter will be fit to the old hardness for connecting to the new valve.
7. secure the valve onto the Refig frame then plug in the water hose to make sure no leak at the valve.
The new valve has new type of self-lock plug ( not Thread ) to the 2 water hoses. Make sure to press hard so the hoses are fit in to these new water .
valves.

Turn on the water and power on on the Refrig. That's all. Very simple save $300 for hiring the service man. Good Luck to all.
All Instructions for the CSC24GRSBWH
16-30 of 889