Models > CSC24GRSBWH > Instructions

CSC24GRSBWH Hotpoint Refrigerator - Instructions

All installation instructions for CSC24GRSBWH parts

These instructions have been submitted by other PartSelect customers and can help guide you through the refrigerator repair with useful information like difficulty of repair, length of repair, tools needed, and more.

All Instructions for the CSC24GRSBWH
61-75 of 924
Search Instructions
Keep searches simple, eg. "belt" or "pump". Need help?

Defrost Thermostat quit working

  • Customer: Jimmy from Palmer TN
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 8 of 10 people found this instruction helpful
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.

This replacement of the light shield was fast and easy. I wish they all good go this smooth.

  • Customer: Stephen from Northglenn CO
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 7 of 7 people found this instruction helpful
I repaired as follows. 1) Open freezer door. 2)Removed ice maker bin. 3) removed screw with broken tab on it. 4) install new shield slide to side.
5) Reinstall screw. 6) Grab TAB (tasty adult beverage) and enjoy on back deck while talking about how good you are at repairing stuff.... HA!

Ice Maker Timing was off

  • Customer: Mark from Antelope CA
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 7 of 7 people found this instruction helpful
The Ice maker would not run through a cycle. It would fill with water and produce ice but would need a little help by pressing up on the ejector to run through its cycle. Otherwise, it would not bring the ice to the holding bend. Sometimes the water would not fill. The icemaker was making ice it just was not letting the ice maker run through its cycle so I figured it had to be the circuit board. I bought the circut board which was easy to install.
1) Turn off water line and unplug power.
2) Pop off front panel plate at ice cube select switch area.
3) Unscrew 4 screws that holds control panel housing in place.
4) Remove panel assembly by disconnecting two different wiring plugs.
5) Unscrew 2 screws that allows access to control circuit board at end cap.
6) Remove circuit board by sliding it out of the assembly housing.
7) Install new circuit control board in assemble housing and screw on end cap retainer.
8) Attach two electrical wiring plugs.
9) Install control board assemble housing into frig opening and secure with 4 screws.
10) Install front panel plate (pops on).
11) Plug in power and turn on water line.

Flapper not sealing. Frost buildup on inside of freezer door

  • Customer: D from ZELLWOOD FL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 7 of 7 people found this instruction helpful
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved

ICE MAKER CAP BROKE

  • Customer: TIM from GRETNA LA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 8 of 11 people found this instruction helpful
IT TOOK ME ABOUT 15 MINUTES TO COMPLETE THE REPAIR, 1ST I EMPTIED THE ICE MAKER, THEN I REMOVED 4 SCREWS FROM THE REAR OF THE ICE MAKER TRAY AND TOOK THE PLASTIC PIECE OFF OF THE AUGER. I REVERSED THE STEPS AND PUT IT BACK TOGETHER.

Water and Ice acuator had a hole in it. Need to be replaced.

  • Customer: Lowell H from Gilbert AZ
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 7 of 8 people found this instruction helpful
Used my fingers and pulled the old one our and pressec the new one in all in about 30 seconds. Saved at least a $60 service call.

broken ice maker

  • Customer: robert from bensalem PA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 7 of 8 people found this instruction helpful
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.

NOISEY MOTOR, BEARINGS OUT, DYING

  • Customer: PERRY from VANDERBILT MI
  • Difficulty: Easy
  • Time to Complete: More than 2 hours
  • Tools Required: Nutdriver, Wrench set
  • 7 of 8 people found this instruction helpful
REMOVE BACK COVER, EXPOSING FAN MOTOR. TURN OFF POWER, REMOVE NUT ON FAN BLADES. REMOVE FAN CAREFULLY, DO NOT BEND. UNHOOK WIRING HARNESS. REMOVE THREE SCREWS THAT HOLD THE MOTOR ON THE BACK FRAME. REMOVE OLD MOTOR, INSTALL NEW. CAREFULLY, REINSTALL FAN BLADES, HOOK UP WIRING, AND YOUR READY FOR TRYOUT. ALSO DO SOME CLEANING WHILE YOUR THERE. CLEAN OLD FAN BLADES WITH HOT SOAPY WATER OR CONTACT CLEANER. EVERYTHING RUNS BETTER CLEAN!

Very low flow from water dispenser, hollow ice cubes, broken ice dispenser helix

  • Customer: Osvaldo from Miami FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Wrench(Adjustable)
  • 8 of 11 people found this instruction helpful
Unplugged refrigerator. Removed cardboard cover, vacuumed lint from coils and equipment area. Removed dual valves and labeled the four electrical leads with masking tape. Cut off the end of water lines to dispenser and ice maker to remove threaded connections (New are simply push on). The water leads are of different diameters, so there is no confusion.
Decided to replace water line at the same time so bought a plastic replacement for less than $10, removed old copper line and replaced it with new. (Original plumber used a custom made line with a smaller diameter and this may have contributed to the low flow).
Connected all lines and wires (had to use adapter supplied with valve for two of the leads which are of different connector widths than original) and secured valve and back panel. Had to bedn the valve mounting plate somewhat to allow it to fit (this is also a little different from the original).
After installation, it takes a little time to refill the lines until proper flow is established both at the dispenser and the icemaker.
Replacing the Helix took completely disassembling the ice drawer, Take your tiime in doing this as there are many parts that fit in only one precise way. This helix replacement took about 20 minutes total.

leaking water / icemaker valve

  • Customer: Lorry from Bentonville AR
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 8 of 11 people found this instruction helpful
Simple. UNPLUG THE FRIDGE. Remove set screw holding valve to frame, switch hoses one at a time into new valve, switch wires one set at a time from old to new, re-attach the new valve, turn on water , plug in fridge, check for leaks. 2-minute job.

freezer coil iceing up

  • Customer: Paul from Palmdale CA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 6 of 6 people found this instruction helpful
removed freezer racks and back panel. removed and relaced defrosting harness. reassembled compartment
PartSelect rocks! easy to locate needed parts. price is fair and quick shipping. saved me $$$$

Refrigerator warm / Freezer iced over

  • Customer: David from Lynnwood WA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 6 of 6 people found this instruction helpful
I began by turning off the refridgerator and then removing all of the drawers/bins and icemaker from the freezer.

I removed the three phillips-head screws across the top of the rear access panel. (same height as the light bulb) I then removed the two phillips-head screws from the bottom of the access panel.

I removed the access panel by swinging the left side forward to clear the drawer slides, while keeping the right side back against itsattaching points. (Like a door swinging on its hinges.)

I followed the wire harness from the upper heating element up to its connector and unplugged the defrosting heaters from the plug. I then gently removed the little (just smaller than a tea light candle) thermostat from the top of the coils. (Not far from where the wire connector was.)

I removed two phillips head screws for each heater unit and removed the whole thing as on big assembly.

I installed the new parts from the bottom up, careful not to damage anything. I installed the new thermostat carefully and then reconnected the wire harness. Next I reinstalled the access panel, starting twith the top center screw to hold it in place during the installation of the other 4 screws in the corners.

Lastly, I put the drawers / bins and icemaker back in and turned the refrigerator back on. DONE.

It corrected the problem. THANKS for the Great Customer Service, too!

would not defrost

  • Customer: Richard from Quakertown PA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Socket set
  • 6 of 6 people found this instruction helpful
First I removed the light cover, one screw. Then I removed the rear coil cover, three Phillips screws and two hex head screws. I then defrosted the coils and removed the old defrost element and wiring harness, two hex head screws held in the element, wiring harness just unplugs. I the installed the new defrost coils ( new one had two coils but had a previously designed area for the second element ) and ran the wiring harness up to where the plug was. I then reinstalled the coil cover plate, and light guard and started the refridgerator. Frige runs like new. Thank you PartSelect for the extremely propmt delivery and the correct part. part

Door wouldn't stay closed & was out of alignment

  • Customer: Rod from Nashville TN
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set, Wrench set
  • 8 of 12 people found this instruction helpful
This repair replaced two riser cams - one attached to the bottom fridge hinge and one attached to the bottom of the door. The two cams
mate together. So, don't just buy one cam, buy two.
1. Removed all contents off the inside of the door as well as the bins.
2. Unscrewed single screw holding plastic cover over top hinge.
3. Unscrewed 2 screws holding top hinge to the top of the door and removed the top hinge.
4. Pulled door up and off bottom hinge and layed
on floor.
5. Removed plastic grill on bottom of fridge.
6. Removed 2 screws holding bottom hinge in place.
7. Using a vice to hold the hinge, I used a hacksw to cut through the rivet holding the riser cam to the hinge plate.
8. Used a small bolt & nut to secure the new riser cam to the hinge plate.
9. Reattached hinge plate to the bottom of the fridge.
10. On bottom of the door remove two screws holding riser cam to door.
11. Position new riser cam in place and reattach to bottom of door.
NOTE: on my door, the metal SHIM that goes between the cam riser & door was also broken. I ordered the replacement SHIM but it turned out to be made of PAPER. So, I didn't bother putting it on. If the riser cam wears out again, I'll just replace it again.
12. Put door back on and secure the top hinge to the top of the fridge and you're done.

Refrigerator door wouldn't close automatically.

  • Customer: Christopher from N. Merrick NY
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers, Socket set
  • 6 of 6 people found this instruction helpful
Removed the top hinge with a socket and lifted the door off. Removed the bottom hinge from the refrigerator with same sized socket. Used a Dermel to cut out the old rivet holding the old mangled cam. Attached the new cam with a screw, washers and nut. Reattached bottom hinge to the refrigerator. Removed the bracket holding the second cam on the bottom of the door. Replaced the shim and cam. Reinstalled the door. No problems. Just don't make the same mistake I made. You need two cams. They interlock and work together to close the door automatically. The cams are identical. They are just off set by 90 degrees when the door is closed.
All Instructions for the CSC24GRSBWH