Defrost Thermostat quit working

  • Customer: Jimmy from Palmer, TN
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 10 of 12 people found this instruction helpful
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.

This replacement of the light shield was fast and easy. I wish they all good go this smooth.

  • Customer: Stephen from Northglenn, CO
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 9 of 9 people found this instruction helpful
I repaired as follows. 1) Open freezer door. 2)Removed ice maker bin. 3) removed screw with broken tab on it. 4) install new shield slide to side.
5) Reinstall screw. 6) Grab TAB (tasty adult beverage) and enjoy on back deck while talking about how good you are at repairing stuff.... HA!

ice would not dispense

  • Customer: john from montgomery, TX
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 11 of 15 people found this instruction helpful
I removed 6 screws, unplugged assembly that had motor attached,removed from fridg,replaced motor and reinstalled assembly, putting back 6 screws.works like new.
thanks.

Ice Maker Timing was off

  • Customer: Mark from Antelope, CA
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 9 of 9 people found this instruction helpful
The Ice maker would not run through a cycle. It would fill with water and produce ice but would need a little help by pressing up on the ejector to run through its cycle. Otherwise, it would not bring the ice to the holding bend. Sometimes the water would not fill. The icemaker was making ice it just was not letting the ice maker run through its cycle so I figured it had to be the circuit board. I bought the circut board which was easy to install.
1) Turn off water line and unplug power.
2) Pop off front panel plate at ice cube select switch area.
3) Unscrew 4 screws that holds control panel housing in place.
4) Remove panel assembly by disconnecting two different wiring plugs.
5) Unscrew 2 screws that allows access to control circuit board at end cap.
6) Remove circuit board by sliding it out of the assembly housing.
7) Install new circuit control board in assemble housing and screw on end cap retainer.
8) Attach two electrical wiring plugs.
9) Install control board assemble housing into frig opening and secure with 4 screws.
10) Install front panel plate (pops on).
11) Plug in power and turn on water line.

Ice maker ot making ice

  • Customer: Barry from Phoenix, AZ
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 13 of 21 people found this instruction helpful
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.

Flapper was stuck open. Old and warped.

  • Customer: James from Virginia Beach, VA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 13 of 21 people found this instruction helpful
Replaced flapper

icemaker developed a leak and froze over

  • Customer: debbie from chino hills, CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required:
  • 13 of 22 people found this instruction helpful
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.

Noisey Motor, Bearings Out, Dying

  • Customer: PERRY from VANDERBILT, MI
  • Difficulty: Easy
  • Time to Complete: More than 2 hours
  • Tools Required: Nutdriver, Wrench set
  • 9 of 10 people found this instruction helpful
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning while your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!

Compressor overheating - Fridge not Cooling

  • Customer: CHRIS from LAGUNA NIGUEL, CA
  • Difficulty: Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 10 of 13 people found this instruction helpful
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.

ice maker not making ice

  • Customer: Cristina from Los Angeles, CA
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 9 of 11 people found this instruction helpful
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours

Ice Maker was leaking all over freezer compartment

  • Customer: Mary from Langhorne, PA
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench set
  • 9 of 11 people found this instruction helpful
Pulled out the fridge, took off the cardboard back. Get a nut driver instead of screwdriver (easier). TURN OFF WATER NOW. UNPLUG FRIDGE NOW. Removed one screw holding valve. Pulled off electrical connectors. Use two small adjustable wrenches to remove water lines. Tag the plastic tubes (I marked RED and BLUE). Grab the new valve and try to stuff it into the same space. Whoops ! Dang plastic housing protecting the electrical from the water is in the way. Have to cut most of it out to make it fit. By the way, DONT follow the instructions about take the bracket off the OLD solenoid. You don't need it. Just throw it away. Connect the wires (remember to use the adapters sent with the new solenoid) Mount the new solenoid (now that the plastic is out of the way) with the one screw (nut driver). Hook up the supply water line (wrenches). Hook up the plastic tubes (aren't you glad you marked them ?). The tubes just push into the new solenoid, no more threads. I just left the plastic nuts on the tubing. TURN ON THE WATER. Check your connections for leaking. Do this before plugging in the fridge. If OK, plug in the fridge. Run some water on the door, look in about an hour to see if cubes are making now. Put cardboard back on fridge. Push fridge back against wall. CONGRATULATE YOURSELF ON A JOB WELL DONE.

Refrigerator door wouldn't close automatically.

  • Customer: Christopher from N. Merrick, NY
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers, Socket set
  • 8 of 8 people found this instruction helpful
Removed the top hinge with a socket and lifted the door off. Removed the bottom hinge from the refrigerator with same sized socket. Used a Dermel to cut out the old rivet holding the old mangled cam. Attached the new cam with a screw, washers and nut. Reattached bottom hinge to the refrigerator. Removed the bracket holding the second cam on the bottom of the door. Replaced the shim and cam. Reinstalled the door. No problems. Just don't make the same mistake I made. You need two cams. They interlock and work together to close the door automatically. The cams are identical. They are just off set by 90 degrees when the door is closed.

Ice machine wasnt making ice

  • Customer: Robert from Auburn, AL
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 11 of 17 people found this instruction helpful
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!

broken ice maker

  • Customer: robert from bensalem, PA
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 9 of 11 people found this instruction helpful
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.

Burnt out heater defront unit

  • Customer: Fred from Martinez, CA
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 8 of 8 people found this instruction helpful
1. Turned unit off and removed freezer shelving
2. Removed 5 screws on back pannel to expose heaters
3. Deforsted coils with a hair dryer and removed ice cubes
4. Compaired new defrost harness to the existing
5. Removed 4 screws holding the defective harness
6. Installed new heater harness with 4 screws and elec. plug
7. Reinstalled back pannel and shelving
8. Turned unit back on