Valve was leaking at end-cap
Shut off water supply to refrigerator. Unplugged electrical supply. Removed waterline from valve and valve from refrigerator. Disconnected electrical connections to valve. Disconnected water supply from valve to refrigerator. Repeated the process in reverse order using the replacement valve. Checked water in refrigerator door for proper operation and monitored area around valve for leaks before rolling refrigerator back into cabinet space.
Parts Used:
Primary Water Inlet Valve
  • Thomas R. from Lexington, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set, Wrench (Adjustable)
19 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge quit coolingg / freezing
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
Parts Used:
Condenser Fan Motor - 115V
  • JEFF from HAMPTON, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaking inlet water valve
Disconect and Removed cover from back of frig.
Removed water supply pipe (adjustable wrench).
Removed Bracket and Valve Assembly from frig (1 screw).
Marked tube placements with marker so that I could put them back correctly.
Removed power connectors from valve.
Disconected tubes from valve (not that easy to pull off).
Connect tubes on new valve. Plug power connectors back in.
Screw the Assembly back on the frig.
Reconnect water supply & test for leaks.
Parts Used:
Water Valve and Bracket Assembly
  • Gilbert from Tucker, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench (Adjustable)
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator not defrosting.
After gaining access thto the Evaporator Coil, lots of disassembly, I was able to cut the foam (Heater Trough) and remove it first (in pieces). This allowed room to lower the Condensate pan and slide it out to replace the Heating Coil, which was also purchased from you. Don't forget to disconnect the drain hose. Because of the "V" shape of the pan, the rear portion of the foam trough had to be removed to allow reassembly. I still have to verify whether the Defrost Timer is working properly, but the unit is coolingto proper temperatures (Freezer and Refrigerator).

Regards,
Mike Hall
Parts Used:
De-Icing Kit
  • Michael from Tappan, NY
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Will not make ice
Bing , Bang, Boom.
Parts Used:
Ice Maker
  • GEORGE from ELIOT, ME
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator did not cool
i put a new evaporator motor in and now it works fine
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Carl from Kent City, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
10 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan had quit; needed replacement.
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues
Parts Used:
Condenser Fan Motor - 115V
  • John from Divide, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice in freezer running down sides
This is a built-in unit. Remove the external bezel at the top of the unit. Reach through the unit and unplug the frig. On the compressor unit, you'll see a vertical metal panel. Remove the metal panel and the timer is right behind it. Remove one wire at a time and switch it to the new timer. Remove timer and replace with new one.

Just an added comment, GE Service wanted to put an "ice kit" into my unit. The full repairs would have cost $1,000. While I described how to replace the defrost timer, the problem was the tray heater. But that's another story.
Parts Used:
Defrost Timer - 120V 60Hz
  • P. Michael from Tustin, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Leaking from behind refrigerator
Turn off water to the refrigerator and unplug from wall outlet remove the defective inlet valve replace with new inlet valve. Now is a great to clean use a air compressor and vacuum and your old crusty frige will be good as new ! Special thanks to Parts Select fast shipping and original ge parts!!
Parts Used:
Primary Water Inlet Valve
  • Greg from Eden prairie, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
13 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy freezer evaporator fan, bearings worn out
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Todd from Saint Paul, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaked
replaced water valve for 50 dollars, saved about 200 dollars by doing it myself
Parts Used:
Primary Water Inlet Valve
  • David from Tampa, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water/no ice
The first sign of trouble was when the water dispenser would continue to come out after you let up on the button. Then water and ice stopped. Changed the secondary inlet value and the main water valve, as well as a 1/4" water line running to the freezer (it was cracked). Water is working. Ice maker is working better than ever. New life for an aged refrige.
Parts Used:
Secondary Water Inlet Valve
  • Joseph from Cortlandt Manor, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
compressor not starting
Refrigerator is not cooling. Light and fan working. Changed the capacitor.. Still not cooling. Back to discovery mode.It may be the timer
Certainly not PartSelect's fault. They have great service.
Parts Used:
Capacitor
  • H.K. from Seagoville, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator wouldn't cycle into defrost mode without doing it manually.
I removed the shield over the timer and the part that supported the timer. Just unpluged it and pluged in new timer and put back shield. I had already replaced the defrost heaters which had totally burned up. I also replaced the thermostat while I was making the repairs although the old one was still o.k. All the information that I needed to make the repairs I obtained through your website. After looking at several websites to compare prices-etc, I found yours to be the best overall. Thanks-a-million your website is worth it's weight in Cold Food !
Parts Used:
Defrost Timer - 120V 60Hz
  • Ben from Warrior, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
noise from condenser fan
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
Parts Used:
Condenser Fan Motor - 115V
  • donald from opelousas, LA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ZIS48NCB