The freezer was whining and growling like a baby
I replaced the motor that runs the fan in the freezer compartment. Had to remove a number of shields to get to the fan and then some wires and screws to get at the motor. It came with a plug with 4 wires in it and I was supposed to pull 2 wires out of the old plug and place them in the new plug. Long story short the pins would not extract from the plug and the wiring harness was molded in solid plastic, so I ended up cutting the 4 wires to the motor and splicing in the new one and taping them with electrical tape. So far no more moaning and the ice cream is still hard, so I think we nailed it.
Parts Used:
Evaporator Fan Motor
  • James from Madison, CT
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
43 of 54 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cold water reservoir tank was cracked and spraying the interior of the fridge
Symptom was water running out of bottom of fridge. Found water pooled up under bottom drawer. Removed (3) drawers and found water was "spraying" from the reservoir tank at back of fridge. Unboxed the new "tank" and confirmed it was the right one by holding it up to the one still in the fridge. Pulled fridge from the wall; removed the rear bottom cover panel on the back using the nutdriver. Removed the solenoid assy by taking that single hex screw out. Push down on the blue circular flange where tube supply enters solenoid, and release the tubing from the solenoid. Remove front bottom cover with phillips screwdriver. Located 2nd tubing connector below freezer (under the unit) and used the same procedure to release that tube from the coupling. Removed screws from tank on inside of fridge, after removing several shelves that were in front of it. Pulled the tubing from the old unit up and out. Discard. Got new unit and fed tubes through the hole the others came out of (back right corner of fridge) MAKE SURE THE NEW TUBES HAVE THEIR "stoppers" IN PLACE. You don't want to contaminate the new tubes with insulation or other debris. Make sure the "o" ring that seals the tubes on the inside of the fridge (supplied with new unit)and the styrofoam insulation stays in place to keep air from leaking through the holes the tubes go through. Installation of the (2) tubes is simple, simply push them into the connector on the solenoid, and the coupler under the freezer. You'll need to feed the longer tube from the back to the front left corner where this coupler is. After making the connection, I bolted the solenoid unit back to the fridge (only 1 screw) and then tested the unit to see there were no leaks before I buttoned everything up. NO LEAKS!! Put the front bottom grill back on with the (2) phillips screws, and the back bottom cover back on with the hex screws removed near the beginning. Probably took longer to write this than it did to make the repair.
Parts Used:
Water Tank Assembly
  • Thomas from Waynesboro, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
41 of 49 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker stripper arm tine broke off (by me), causing ice to remain and not discharge normally. The cause was a stripperarm tine becoming caught under an opposing tine in the icemaker preventing it from discharging ice altogether.
Installed the new stripper arm per instructions - an easy installation. After a few cycles the original problem happened again, the stripper arm tine caught under an opposing tine stopping the unit from operating. I removed the stripper arm, after marking where it was caught, and filed it down so it wouldn't catch anymore. Icemaker works fine now. Troubleshooting tip. If a stripper arm tine is caught under an opposing tine, gently slide a screwdriver between them to release it without breaking the tine. Remove the arm, file it down 1-3 mm, and reinstall.
Parts Used:
Icemaker Stripper Arm
  • Errol from Mill Creek, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
45 of 61 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker quit making ice
the first thing i did was replace the water valve at the bottom of the refrigerator but that didn't work so then i spent more time researching the problem on your site and your diagnostic said to replace the ice maker so i ordered it, took the old one out, plugged the new one in and we had ice the next day.
Parts Used:
Ice Maker
  • Jeffrey from Bluefield, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
40 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The partion between the tub and dispenser broke
Once I got the correct part, (the expanded view of the icemaker is confusing as it shows the partition at the back of the diagram) I removed the ice dispenser from the tub by removing the screws and disengage the tabs holding the dispenser assembly in the tub. The most difficult step was getting the disenser disengaged from the tub. I used two kitchen knives to wedge between the walls of the tub. It was then easy to remove and replace the broken inside partition and reassemble the dispenser. Works like new.
Parts Used:
Housing Crusher Dispenser
  • Mark from Brandon, MS
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
36 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frost builds up in freezer section and refrigerator stops working slowly. manually defrost for 24-48 hours and starts working perfect. Goes through the cycle again after a week.
As advised by the forum just replaced the defrost heater assembly now the refrigerator works perfect. did not have to replace the thermostat.
My nephew had exactly same problem on ge refrigerator - replaced the defrost heater assembly and the problem is solved. Just remove the back panel in the freezer compartment, disconnect the cable, remove the nuts and replace the assemble. It is very simple. Bought both assembly from parts select.com - got next day delivery. they are great. would do business in future.
Parts Used:
Defrost Heater Harness Kit
  • David from West Palm Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
34 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would not run.
I found if I would put pressure on one connector on the board the unit would come on. So the board had a short. I ordered it, it came in 24 hours and I installed it and problem was solved.
Parts Used:
Main Electronic Control Board
  • Robert from Battle Creek, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
34 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker dispensed crushed ice but not cubes
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap out neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.
Parts Used:
Ice Dispenser Solenoid Service Kit
  • James from Greenville, NC
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
42 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Pieces broke off Auger and Cover cracked.
Remove and empty ice maker from freezer . Remove two screws from bottom to remove the front panel (cover bucket). Remove one screw which holds the deflector on top of the bucket.(tray which holds the ice curbs). Remove one screw that holds the clip that holds the wire actuator rod.

To remove the the ice crusher/dispenser mechanism from the bucket I used two table knives Spread one side of the bucket with one knofe and pry up with the other to get the retainer wedge free from the bucket side. Repeat on the other side. Once the retainer wedges are free the ice crusher/dispenser with the auger attached can be lifted free from the bucket.

With a spanner wrench remove the nylon nut from the shaft. NOTE: THIS IS A LEFT HAND NUT. Note the orientation and relationship of the crusher blades. They must be replaced properly for the system to crush ice and dispense cubes correctly. Remove blades and spacers from Auger.

Reassemble in reverse order. Be sure to get the actuator rod in place in the cam for the dispensor cover before sliding the crusher/dispenser mechanism totally in place. If not in the cam correctly the crusher/dispenser may have to be removed again.

Although a little difficult the first time the project is easily done by an adventourous handy person.
Parts Used:
BUCKET AUGER Dispenser Crusher Cover
  • Larry from Georgetown, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
40 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Quit making ice.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.

Other than the two-screw problem, it was easy.
Parts Used:
Ice Maker
  • Joe from Brentwood, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
37 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water if refigerator door is really slow. Ice making is really slow.
Used by pass filter and problem disappeared. Of course wayer is now unfiltered. This is a GE design flaw. Also replacement filters are outrageously expensive and do not last long. We have good water here and I'll stick with the bypass.
Parts Used:
MWF BYPASS
  • Fred from Edgartown, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
41 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evap Fan was sqeeling
First I removed the shelf and light cover, then removed 3 screws from the ice make. Then I removed 6 screws from the moter cover (back wall of the freezer) and removed it. I then removed the 2 screw holding the moter. This is where the soldering iron comes in. The wire leads from the old motor were molded into a 3" rubber holder and the end wire plastic connector held 6 prongs (2 from a thermo tube). The new motor only held the 4 moter prongs, 2 were empty. To resolve this problem I cut the wires on both the new and old motor. I then attached the old connector to the new moter with the soldering iron and shrink tubing. Replaced all the parts I had removed and started it up. Works like a champ.....
Parts Used:
EVAPORATOR FAN BLADE Evaporator Fan Motor Compression Ring Evaporator Fan Grommet - Grey Lid Bumper Dust Cap
  • David from Raleigh, NC
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
41 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker leaked water slowly and froze the cubes together
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
Parts Used:
Ice Maker
  • Steven from Cave Creek, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
41 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water line froze, food in fridge started freezing
I knew almost as soon as I found the frozen milk that the air-flow diverter, whatever it's called, had broken. It's a plastic part that opens and closes to allow cold air from the freezer into the fridge side.

Step one: clear off the top two shelves and take them out.

Step two: remove the lower piece of the assembly. It pops straight out at the top and drops down after that. If you pull the bottom straight out, you may break the bits that holds it to the fridge wall.

Step three: remove screws holding in light, and then the screws holding in the AASM COVER FF INLET K (wish I had a better name for it).

Step Four: Unplug the unit from the fridge wall.

Installation, reverse, except maybe unplug the unit earlier.
Parts Used:
Air Inlet Cover Kit
  • Bradley from Spokane, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
33 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Was Not Cold Enough To Keep Food Frozen Or Make Ice
I am a single mom of two with limited funds. I had a repairman come out and find the problem and give an estimate. We were told that it was the evaporator fan motor and and the main control board. The repair would cost $400 and no guarantee. So I checked the cost of parts and it was $200 so for no guarantee I figured why not try it myself and possibly save $200. So I ordered the parts from partselect. Even though I paid the cheapest postage they arrived the next day. So from what I read and saw this would be a piece of cake. Well let me just say if the freezer section was gutted to begin with it might not have been that big of a deal. As it was getting to the top screws of the panel that covers the evaporator fan required the removal of the icemaker and all. I am not a tall woman nor am I a thin woman and fitting my body in that small freezer section was not easy. There were times that I had to have my teenagers reach a long arm in and hold a part up for me. After that I discovered that the fan I had purchased only had 4 wires. The one from my old fan had 6. I discovered that 2 of the wires went to some sort of sensor. Long story short I rigged it. I was able to remove the 2 prongs for the sensor and insert them into the empty holes on the new fan harness. It wasnt easy. I have limited tools too and I wont even get into how I did it. They did not fit the greatest so I used the electrical tape to cover the whole connection. I put the whole thing back together and debated on trying it without putting in the main board but I decided to trust the repairman this time and go for it. Getting to the main board was no big deal. But what disturbed me was the main board I held in my hands did not look exactly like the main board I was about to take out. I watched the video 3 times my how easy it looked. I then read the directions that came with it. It talked about removing a pin and cutting a wire. Well I about had a stroke worrying. I finally found the serial # on my frig and thankfully mine was not on the list. However the directions did still say something about if there wasnt a wire in pin 2 proceed to step 3. Well I had a wire in pin 2. So it was confusing. My serial # wasnt one of the models #'s given but I did have a wire in pin 2. I just took a chance and trusted the serial #'s and ignored the rest of it. I plugged the wires on the new board one at a time. Put the cover back on and prayed as I plugged it in. A soft purr began. It was running. The freezer was around 60 degrees. I put a room thermometer in to make sure it was going down. It kept going down. Around 3 hours after I finished there was a loud noise from the freezer. It had made ice something it had not done in months. I stayed awake most of the night watching and listening to it. It got down in the single digits I was afraid that maybe it would never shut off. It finally shut off as I was making the kids breakfast the next morning. Of course I was worried that it would not restart. So I opened the freezer and fanned in room air. It worked. Since then we have purchased no more dry ice or regular ice. We bought a tub of ice cream and more than one day of school lunch stuff at a time. Bottom line it works. Thanks to everyones post and to partselect for the video. I hope that I never have to do it again though.
Parts Used:
Main Electronic Control Board Evaporator Fan Motor Evaporator Thermistor Clip
  • MARCELLA from FAIRDALE, KY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
39 of 55 people found this instruction helpful.