Ice maker quit making ice
the first thing i did was replace the water valve at the bottom of the refrigerator but that didn't work so then i spent more time researching the problem on your site and your diagnostic said to replace the ice maker so i ordered it, took the old one out, plugged the new one in and we had ice the next day.
Parts Used:
Ice Maker
  • Jeffrey from Bluefield, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
40 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator side of the side by side refrigerator stopped regulating its temperature causing cans and bottles to burst.
I removed the back panel held in place by 5 screws. I located the thermostat and disconnected it from the wire connection to another part. Due to the connection requirement, I had to cut the wires from the original part and splice the connector with wires to the new part. After securing the spliced wires and covering in electrical tape, I replaced the panel and all screws.
Parts Used:
Defrost Thermostat
  • Jonathan from Cary, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
36 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frost builds up in freezer section and refrigerator stops working slowly. manually defrost for 24-48 hours and starts working perfect. Goes through the cycle again after a week.
As advised by the forum just replaced the defrost heater assembly now the refrigerator works perfect. did not have to replace the thermostat.
My nephew had exactly same problem on ge refrigerator - replaced the defrost heater assembly and the problem is solved. Just remove the back panel in the freezer compartment, disconnect the cable, remove the nuts and replace the assemble. It is very simple. Bought both assembly from parts select.com - got next day delivery. they are great. would do business in future.
Parts Used:
Defrost Heater Harness Kit
  • David from West Palm Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
34 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leak on the water valve
I had noticed water on the front left of the fridge on the floor.I thought it was the drain in the freezer so i poured hot water with baking soda into the drain but it didn't help..I pulled the fridge out and saw water dripping from the water valve solenoid.I searched the web for parts and found Parts select.com.I found the part quickly and they had pictures from all angles to assure me that it was the exact part which was great.The transaction on line was simple and the part came the next day.I will definitly use this sight again
Parts Used:
Primary Water Inlet Valve
  • JAMES from LEDGEWOOD, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
44 of 65 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker dispensed crushed ice but not cubes
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap out neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.
Parts Used:
Ice Dispenser Solenoid Service Kit
  • James from Greenville, NC
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
42 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Quit making ice.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.

Other than the two-screw problem, it was easy.
Parts Used:
Ice Maker
  • Joe from Brentwood, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
37 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker leaked water slowly and froze the cubes together
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
Parts Used:
Ice Maker
  • Steven from Cave Creek, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
41 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Older Side By Side GE refrigerator needed filter replaced
Because of the age of the refrigerator, I was unable to find original water filter replacements. I found an adaptor through PartSelect, ordered and received it within 3 days. I was then able to find a replacement filter to work for my appliance. It was easy to install. The Adaptor snapped into the port where the old filter went and the new filter screwed into the adaptor...Water / Ice system is working like new again.

Thanx
Joel
Parts Used:
Water Filter Adapter
  • Joel from Flagstaff, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
42 of 63 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaking Water
Unplugged frig. Turned off water supply to pump. Removed black cardboard covering on back of frig with nut driver (6 screws).

Took digital photo of assembly to confirm reassembly position.

Removed copper waterline to pump with adjustable wrench. Removed 1 screw holding pump assembly to refrigerator. Pulled assembly out of the frig. Unscrewed two small black screws on a second bracket. Pulled old pump further out of frig. Unplugged two connectors. Removed plastic waterline from pump by turning hose counter-clockwise and gently pulling.

Inserted plastic water line into new pump by turning line in clockwise and it pushing into orange plastic stop. Reconnected two electrical connectors. Reconnected bracket to pump with two small black screws. Gently pushed assembly back into the frig and reconnected pump assembly to the frig with 1 screw. Reconnected copper water line to pump first wrapping threads on pump with Teflon plumbers tape.

Turned on water to check for leaks. Installed cardboard back on frig with 6 screws. Plugged in frig.

NOTE. My new pump assembly had the electrical connectors reversed. Take care to pair up the correct colored connectors.
Parts Used:
Primary Water Inlet Valve
  • Paul from Danvers, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
37 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water dispenser in door failed to dispense water
Unplugged refrigerator from electrical outlet for safety and turned off water supply valve. Removed the four metal screws that hold the access cover on the rear of the refrigerator. Then removed single metal screw attaching water valve and bracket assembly. Unplugged wire harness from the water valve and assembly then pressed down on colored o-rings to detach the four plastic water lines from the water valves. Used open end wrench to disconnect main water supply line from the water valve.
Pressed down on colored O-rings to install the four plastic water lines to new water valve and bracket assembly. Wrapped plumbing tape on threads of inlet valve and and used open end wrench to attach main water supply line to new water valve and bracket assembly. Attached wiring harness to new water valve and bracket assembly. Mounted new assembly to refrigerator with single metal screw. Turned on water supply valve and checked for leaks. Plugged in refrigerator to electrical outlet and tested water dispenser. Replaced access cover on rear of refrigerator with four mounting screws.
Parts Used:
Water Valve and Bracket Assembly
  • Robert from El Paso, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
31 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice was melting and freezing in bucket
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
Parts Used:
Ice Maker
  • John from Lodi, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
33 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The selector switch to select water - crushed ice - or cubes broke off
Removed the face plate this just gets popped off. removed the four screws to release the unit. unplugged the wiring harness, removed the two screws that hold the bracket in place that the control unit is housed in. Slid the old unit out and replaced with the new unit. installed the bracket over the control unit put two screws back, plugged the wiring harness's back in. Slid the whole unit back in replaced the four screws and put the face plate back on. Very Easy.
Parts Used:
Dispenser Control Board - 2 Slide Switches
  • Christopher from No. Massapequa, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
31 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rust had formed on some of the parts
I had to completely disassemble the ice bucket (dispenser) to gain access to the parts that were being replaced.
*
It was helpful to have the exploded parts diagram to aide in reassembling the ice dispenser when replacing the parts.
Parts Used:
Ice Dispenser Blade Ice Dispensing Drive Cup Ice Bucket Auger Front Helix
  • james from garland, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
38 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Heater coil in frost-free freeze side fail (second time)
Remove freezer contents, shelves, and interior back-panel. Melt all ice on freezer coolang coil with hair dryer. Be careful not to touch to coling fins on the coils with the hair dryeer since they damage easily. Unplug the old heater coil wire harness at the top of the coils. Gently remove the thermocouple clipped to the top coil. Gently remove the wires leading down to the heater coil at the bottom-back of the freezer. Remove the old heater by removing the two mounting screws. Install new heater by reversing the steps above.
Good luck.
Ps. When the heater coil fails the result is, both the freezer and refridgerator sides get warm and food spoils. A good indicator to watch for is frost building up in the freezer on the interior back-panel. I taped cheap thermometers in both side to help mointor the temperature in case it happens again.
Parts Used:
Defrost Heater with Thermostat
  • Keith from Osceola, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
29 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cold, Refrigerator Section Warm
The problem with this model is usually a burned out heater assembly, when the freezer is still freezing, but the fresh food section is warm. To check, first disconnect power from refrigerator. Remove food and then shelves from freezer section. Remove the screws that hold the back freezer panel in place. Remove back panel and the coils will be exposed. If they are covered in ice the heater is most likely the problem. At the bottom of the coils below the heater assembly is a drain hole plug this hole with a rag. Place a large towel in bottom of freezer pan beneath the coils to catch the water. I do not recommend any method to melt the ice from the coils but a hair dryer, do not chip at the ice or you will most likely damage the coils. After you have defrosted the coils and removed all water from the unit, remove the two screws that hold the heater element in place, this element is directly below the coils. Look at the element, if it is burnt black, this is a tell tale sign it is bad. If that is the case it will need to be replaced. Remove the electrical wires located on te end of unit, the new unit will have instructions with it, reconnect the electrical wires per instructions, remount heater with the same mounting screws that held it in place. Be sure to remove rag from drain hole, replace back freezer panel with screws, replace shelves, and plug refrigerator back in. If your problem was a cold freezer section but a warm fresh food section this should fix your problem. In conclusion, this problem and the fix for it is indicative to these model's ge refrigerator's
Parts Used:
Defrost Heater Harness Kit
  • CLIFFORD from SPRING CITY, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
30 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ERS2022DABB