Ice maker water valve failed open.
The replacement single outlet water valve was not an exact replacement and required a slightly different mounting position. The original plastic hose to the ice maker attached to the valve with a plastic nut. The new connection requires only pushing the hose into a hole in the valve. Easy and simple. However, the new mounting angle promptly broke the brittle old plastic hose. I was able to pick the broken pieces of hose out of the valve with a fine point pick saving the new valve. If I hadn't been able to pick the broken pieces out of the new valve I would have had to order another one. Off to the big box store to buy new 1/4 inch plastic hose and a coupler. Repair completed and no leaks. If the hose hadn't broken, the I would have been done in 15 minutes. I suggest you plan to replace the entire plastic hose when you replace the valve.
Parts Used:
Single Outlet Valve Kit
  • O. V. from Virginia Beach, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set, Wrench set
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker solenoid housing cracked
The original piece was already removed. installation required a little custom fitting as the mounting was slightly different and the copper tubing from the water line needed to be bent to fit. The push in plastic connection (output to the icemaker itself ) was simple ( I was a little leary of it not leaking.)
I plugged in the solenoid connection first
I attached both water lines and checked for fit. Made the adjustments and then screwed the bracket back on to the refrigerator. I could only install one screw but it holds it fine. I did have to trim the hard press board(cardboard) a little to fit the new valve. I believe the board is to protect against dust build up on the mechanical equipment (motor, condenser,etc)
Parts Used:
Single Outlet Valve Kit
  • Mark from Bayside, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Wasn't Getting Any Water To The Icemaker
It could not have been easier. The new part matched the old part exactly. I turned the water off going to the refrigerator, unscrewed one screw from the old part, pulled the electric plug loose, disconnect the copper water line from old part, cut off the black plastic tube next to the water valve going to the icemaker, and the new water valve was ready to install. It's that simple. I then took the new water valve, connected the copper water line to it, pushed the black plastic water line into its hole, connected the electric plug, and screwed the new part onto the refrigerater. In a matter of minutes I had water running to my icemaker again. I can't imagine the money I saved by doing this simple project myself. This took less than 10 minutes.
Parts Used:
Single Outlet Valve Kit
  • Mark from Ft. Lauderdale, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working.
I first replaced the ice maker and when that didn't work, I found out through this forum that another possibility is the water outlet valve.

When I got the replacement, it took some time to install because the bracket wasn't the same as the original. There are enough places on the bracket to mount the unit, but it may require using some force to bend the bracket so that it will flush with the wall.

After installation, it took about 2 days to fill up the ice bin. It cycles out ice crescents every 2-3 hours.

Thanks partselect for having this forum and saving me some money by having others share their experiences.
Parts Used:
Single Outlet Valve Kit
  • Alice from Vancouver, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old timer quit working.
Installed the new timer.
Parts Used:
Defrost Timer - 120V 60Hz
  • John from Mesa, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
cracked valve
Super simple. Extremely fast delivery of part. Simply disconnect the 2 fast-on connectors to valve, disconnect intake and out lines. connect intake and out tubes to new unit, mount via screws to fridge, reconnect the 2 fast-on power connectors and your back in business. Could not be an easier repair.
Parts Used:
Single Outlet Valve Kit
  • Don from Crete, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken outlet valve
All the repair people was on the money . I read them all .1--- NO paper work with new valve (.no instructions) ..2--- bracket is not the same .. I reversed my braket and it worked fine .you do not have to bend bracket.3--- It will take a day or so to start making ice..4--- the plastic nut is no longer needed on the new type outlet valve ....5--- the new outlet valve looks a little different from the old valve. WORKS GREAT ..
Parts Used:
Single Outlet Valve Kit
  • KEITH from WINDER, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer cold but refrigerator warm, would not cycle the defrost on freezer
two screws and a connector were removed to replace the timer.
Timer was located on the top front of fridge
Parts Used:
Defrost Timer - 120V 60Hz
  • MATT from OAKLAND, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer too cold and refrigerator not cold enough because fan not working
Had to defrost a bit and then was able to remove rear freezer panel by simply removing the 2 screws holding it in place.
Old motor easily removed from its mounting bracket. and replaced with the new. Had to use the two wires sent with the motor. I clipped off the male connectors and joined them with wire splicers to the black and red wires clipped from the old motor. Then reinstalled.
The replacement motor works great. I was afraid the old fan blade might not fit but it slid on perfectly.
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Ann from LAPORTE, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water not being drawn up into icemaker
unplugged the old valve and disconnected the water line, then reconnected water line on new valve and plugged it in. It was an easy process but unfortunately that did not fix the problem. It is the ice maker it self so I will be ordering a replacement ice maker.
Parts Used:
Single Outlet Valve Kit
  • timothy from aberdeen, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old solenoid was slow to shut off causing the icemaker to overfill.
Unplug refrigerator and turn water supply off to the ice maker. Remove the screws holding the bottom cardboard-like cover from the lower back of the refrigerator. Remove the water supply line to the old solenoid with 1/2 inch wrench. Unplug the two power supply wires to the old solenoid. Remove the screw that holds the solenoid to the back panel of the unit. After the solenoid is pulled out, remove the output hose with a 1/2 inch wrench. The configuration of the replacement solenoid is likely a little different than the original, but it seems to be rather universal and will fit back into place and perform properly. The new solenoid does not use a compression type nut to secure the output line. It's just a simple push-in connection. The wires may have to be rerouted a little, just keep them clear of the evaporator fan blades Reverse the removal procedure and you're done.
Parts Used:
Single Outlet Valve Kit
  • Cliff from ROCKVILLE, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Wrench set
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leaking from bottom of refrigerator
I'm not a DIY-er, and wasn't sure a 20 year old refrigerator was worth the repair, but for $30 I could afford to be wrong. The swap is pretty intuitive, especially in my case since the problem was that the water tube from the valve to the ice maker had detached from the coupling. So I didn't have to cut anything off, just inserted the tube into the new valve. Reconnected the supply line, screwed the assembly back on the refer, and Bob's your uncle. Other than unloading some canned goods to lighten the refer, longest process was finding the right size nut driver in my disorganized tool tray. Be aware, there are NO instructions included with the part. Found a good video on you tube that confirmed the obvious. Glad I took a shot!
Parts Used:
Single Outlet Valve Kit
  • Bill from ORO VALLEY, AZ
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator stopped making ice
Removed the old water valve from back of refrigerator by using a screwdriver. Pulled water line off old valve that runs into the fridge and inserted it into the new part. I used a pair of pliers to take off water line that runs into the water valve from the house. Screwed the water line back onto the new valve. Took about 10 minutes.
Parts Used:
Single Outlet Valve Kit
  • Doug from COPE, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Original evaporator fan (31 years old) was making a lot of worn bearing noise
Empty freezer;
Remove shelves and ice trays;
Unscrew and remove the rear vertical panel;
Unscrew and remove fan housing;
Unscrew and remove fan from fan housing;
Fan blade slides off the motor shaft without tools.
Reverse order to reassemble with new fan motor.

I did have to use the wire extensions that were included as the replacement motor had the electric connections in a different location from the original motor.

Overall, this was an easy replacement.
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • T from SOUTHBURY, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan would not turn when the refrigerator came on all the time. Would physically have to turn the fan blades.
Did not do the repair because the unit arrived damaged. The packaging was in good condition. The plastic around the plug in shattered, and some of the plastic was inside the motor. Very good, and fast on adjusting the order.
Parts Used:
Condenser Fan Motor - 115V
  • David from CLIFTON, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the BCS42CKC