Models > ASD2514ARA > Instructions

ASD2514ARA Admiral Refrigerator - Instructions

All installation instructions for ASD2514ARA parts

These instructions have been submitted by other PartSelect customers and can help guide you through the refrigerator repair with useful information like difficulty of repair, length of repair, tools needed, and more.

All Instructions for the ASD2514ARA
46-60 of 637
Search Instructions
Keep searches simple, eg. "belt" or "pump". Need help?

Fridge stopped working

  • Customer: Dan from Sumner WA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 7 of 8 people found this instruction helpful
I called a repair man from a pretty large name to come out and take a look. He found out in about 10 minutes that it was a bad capacitor. The quote he gave me was $75 for the part and $175 labor. I tried my best not to laugh and tell him no thank you. He did have to charge me for him to show up, which was only $98.
So I used what he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.

Ice bucket auger yoke was stripped out and turned freely

  • Customer: James from Pineville LA
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Screw drivers
  • 6 of 6 people found this instruction helpful
Removed the ice bucket from the freezer. Removed the single screw on the left side with a nut driver, then lift and pull the tray toward you...there is a wiring harness in back of the tray that I had to unplug...easy, pinch the sides of the plastic connector and it disconnects..and the tray came out of the refrigerator...and the cussing started. Since the threaded yoke was stripped it could not be unscrewed from the motor shaft...I took my trusty Dremel Tool and cut the shaft off so the yoke could be separated from the motor shaft and the motor could be removed from the plastic housing. From here on it was a piece of cake...install the new motor and screw the new yoke onto the motor shaft... I think it has a left handed thread, like the old propane bottles used to have..slide the tray back in, reconnect the wiring harness (it only plugs in one way), make sure the tray is sitting on the 4 side supports, put the single screw on the left side and you are done....put the ice bucket back in and flip the bail down and you should be back on business....!!

Compressor not working

  • Customer: Terry from Knoxville TN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 6 of 6 people found this instruction helpful
Extremely easy install. Just popped off the cover located on the side of the compressor. Noted placement of the wires on the overload and relay. Took a small screwdriver to slide both from the electrical pins on the compressor...take care doing this. Unplugged the wires, plugged the new components to the wires and installed to the compressor. Plugged in the frig and the compressor came on. Not sure why these went out to begin with but the fix was extremely easy and saved me the expense of a repair man.

No ice

  • Customer: Jon from Boise ID
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 8 of 12 people found this instruction helpful
1 screw remove assembly. Unplug cable harness and remove old cover and wire arm. Replace cover and wire arm and attach wire harness on assembly end. Re attach using screw removed in first step. Plug in wire harness. Making ice within 30 minutes.

Condenser fan motor seized

  • Customer: Benjamin from Daytona Beach FL
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers
  • 6 of 6 people found this instruction helpful
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.

Ice stripper broken on ice maker

  • Customer: Kenneth from New Braunfels TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 8 of 12 people found this instruction helpful
I unplugged the fridge. Loosened the 2 top screws on the ice maker and removed the lower screw. I disconnected the wiring harness and removed the Ice maker. I removed the plastic timer cover in front. I then loosened the screws on the face of the ice maker and removed the broken ice stripper and replaced it with a new one. Re-tightened the screws on the face, installed the timer cover, plugged in the wiring harness, re-attached the ice maker. Plugged the fridge back in and walla, it was making ice in 30 minutes!

Fan Motor making screaming noise

  • Customer: Daniel from Auburn CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench(Adjustable)
  • 8 of 12 people found this instruction helpful
First I unplugged the refrigerator, then next I removed the (4) screws holding in the inside back panel section of the freezer covering the cooling coils, the fan motor is attached to the removable panel.
I then unplugged the wiring harness to the fan motor which allows you to completely remove the freezer inside panel in order to replace the fan motor on a counter top or benchtop.
I removed the (3) spade terminal wiring from the fan motor and the nuts holding the motor on the frame. I then replaced the fan motor and blade the same way I had removed the old one, and then reattached the wiring terminals on the same terminals as the existing motor, making sure that black, red, and green do not get mixed up. I placed the rear panel back inside freezer and plugged in the wiring harness, fit panel back to original position and reinstalled the (4) panel screws. I once again plugged in the refrigerator and restored power. Everything is working fine.

fan had stopped-freezer not performing etc.

  • Customer: George from Glenwood MN
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers
  • 6 of 6 people found this instruction helpful
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!

Ice maker over flowing

  • Customer: ben from manhattan KS
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers
  • 6 of 7 people found this instruction helpful
My ice maker was overflowing and i realized that it was the water valve that needed replaced. unscrewed 1 nut, unhooked 3 water lines, unhooked electrical components and re-installed in reverse order. took about 10-15 mins.

freezer will not freeze or cool the ice box

  • Customer: David from Choctaw OK
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Socket set
  • 6 of 8 people found this instruction helpful
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson

noisy fan motor, fridge & freezer not holding temp

  • Customer: Paul from Joshua Tree CA
  • Difficulty: Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 7 of 11 people found this instruction helpful
I took off the ice maker, disconected the wiring, took out the back of the freezer and took out the fan motor. Harder than I thought because of all the wiring back there, light, fan assembly etc. After that it was easy, took out the old motor & installed the new one. Runs much quieter now, and the fridge & freezer are much colder.
I did this for less than the price of a service call by a repair shop.

Ice maker stopped working

  • Customer: Ronald from Chardon OH
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 5 of 5 people found this instruction helpful
Since I had no water in the try I started with the valve first. That did not fix the problem so I replaced the Ice Maker assembly however that still didn't solve my problem. The only thing left was the relay that entergized the valve. The part number shows NLA so I googled the part number on the relay and found one at Mouser Electronics under PN:G2R-1A-T-AC120. The whole project took me several days to solve however the actual time involved was only about 1 hour.

The Shaft of the Auger Drive Motor Became Stripped

  • Customer: Anthony from Amenia ND
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 7 of 11 people found this instruction helpful
I removed the one nut screw holding the Ice bucket shelf then removed the Ice Auger Container. Then I lifed the Part containing the Drive Motor. I removed the electrical connection which just plugs into the fridge. Once the Drive motor and container was out of the fridge I removed 4 screws and the Drive motor was out. I disconnected 3 electrical connectors and connected them to the new drive motor. Then replaced the motor and connected the 4 screws. I then installed the yolk on the drive shaft and then put the drive motor container back in the fridge and reconnected the electrical. Installed the nut screw and I was done.

Ice maker not dispensing ice

  • Customer: Travis from Westchester CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers
  • 5 of 6 people found this instruction helpful
Removed about 6 screws. Replaced the solenoid and door kit. Replaced the screws. These parts were easy to replace. They were also super easy to identify and order from the site. I received them two days after I placed my order.
Thanks partselect.com!

ice maker chute door not working

  • Customer: DOUGLAS from MILFORD PA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 5 of 6 people found this instruction helpful
removed outside water spill tray and removed exterior cover & interior cover exposing the door arm and solenoid. replaced with new parts including spring. Elontronics have a plug which is easy to disconnecct. & reconnect
old solenoid head would not have fit new door arm
and vice versa.
I strongly suggest using the kit.
A Torx type screw driver is required for all screws
on the Jenn-Air
All Instructions for the ASD2514ARA
46-60 of 637