Fridge stopped working

  • Customer: Dan from Sumner WA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 9 of 10 people found this instruction helpful
I called a repair man from a pretty large name to come out and take a look. He found out in about 10 minutes that it was a bad capacitor. The quote he gave me was $75 for the part and $175 labor. I tried my best not to laugh and tell him no thank you. He did have to charge me for him to show up, which was only $98.
So I used what he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.

Fan Motor making screaming noise

  • Customer: Daniel from Auburn CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench(Adjustable)
  • 10 of 14 people found this instruction helpful
First I unplugged the refrigerator, then next I removed the (4) screws holding in the inside back panel section of the freezer covering the cooling coils, the fan motor is attached to the removable panel.
I then unplugged the wiring harness to the fan motor which allows you to completely remove the freezer inside panel in order to replace the fan motor on a counter top or benchtop.
I removed the (3) spade terminal wiring from the fan motor and the nuts holding the motor on the frame. I then replaced the fan motor and blade the same way I had removed the old one, and then reattached the wiring terminals on the same terminals as the existing motor, making sure that black, red, and green do not get mixed up. I placed the rear panel back inside freezer and plugged in the wiring harness, fit panel back to original position and reinstalled the (4) panel screws. I once again plugged in the refrigerator and restored power. Everything is working fine.

Door flap not opening correctly and noise when pushing button for water

  • Customer: Charles from Allen TX
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Wrench set
  • 8 of 8 people found this instruction helpful
This repair was relatively easy due to the instructions provided and took about 15 minutes. Originally, I had bought a door flap thinking that was the problem (a small plastic piece on the flap had broken off) but after replacing that the assembly still would not allow ice flow. I then purchased the kit including solenoid and the repair worked. I had a bad solenoid all along. My suggestion is to replace the entire kit rather than one part as it is likely all parts need replacement.

the ice/water actuator switch burnt out and was stuck on.

  • Customer: Jon from Nampa ID
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 8 of 9 people found this instruction helpful
Removed the rubber cover over the actuator switch. Used a screwdriver to remove the switch, disconnected the wires. I then removed the switch from the mounting bracket using a small philips head screw driver. Installed the new switch on the mounting bracket then installed the switch onto the freezer door. The only difficult part was installing the rubber cover. Now I just need to repair the damage to my hardwood floors and carpet from all the water.

No water to icemaker

  • Customer: Philip from Mission Viejo CA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Wrench(Adjustable)
  • 8 of 9 people found this instruction helpful
Easy to diagnose problem because there was water to the water dispenser but none to the newly installed icemaker. Originally did attempt to clean the solenoid but found the plunger assembly damaged.

New part arrived sooner than I thought it would. Takes about as much time to remove the lower vent cover as to replace the valve. Remove the electrical plug from the wall, valve off the main water supply, remove lower vent cover, disconnect the supply hose from refrigerator valve assembly, remove one hex head mounting screw and you have both water valves in your hands. Identify the valve the supplies water to the filter and the one that supplies water to the icemaker/water dispenser. Then confirm which plastic water supply line goes to the water dispenser and which goes to the icemaker. Hose diameters are different but it is good to know. Disconnect the plastic water supply lines from both the ice dispenser and the icemaker portions of the valve. Replacement solenoid valve does not have thread on type compression fittings. Snip about an inch off of each hose and then press into the appropriate valve orifice.

Making sure the plastic supply lines do not get crimped, remount the valve assembly, reattach the supply hose, valve on the water and check for leaks. No leaks, reinstall dust cover and plug the refrigerator back in.

Move the unit back in place and then take a long deserved beer out and have a celebratory toast for a job well done.

Ice bucket auger yoke was stripped out and turned freely

  • Customer: James from Pineville LA
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Screw drivers
  • 7 of 7 people found this instruction helpful
Removed the ice bucket from the freezer. Removed the single screw on the left side with a nut driver, then lift and pull the tray toward you...there is a wiring harness in back of the tray that I had to unplug...easy, pinch the sides of the plastic connector and it disconnects..and the tray came out of the refrigerator...and the cussing started. Since the threaded yoke was stripped it could not be unscrewed from the motor shaft...I took my trusty Dremel Tool and cut the shaft off so the yoke could be separated from the motor shaft and the motor could be removed from the plastic housing. From here on it was a piece of cake...install the new motor and screw the new yoke onto the motor shaft... I think it has a left handed thread, like the old propane bottles used to have..slide the tray back in, reconnect the wiring harness (it only plugs in one way), make sure the tray is sitting on the 4 side supports, put the single screw on the left side and you are done....put the ice bucket back in and flip the bail down and you should be back on business....!!

Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always

  • Customer: JAMES from Middleboro MA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 8 of 10 people found this instruction helpful
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels

Condenser fan motor seized

  • Customer: Benjamin from Daytona Beach FL
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers
  • 7 of 7 people found this instruction helpful
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.

fan had stopped-freezer not performing etc.

  • Customer: George from Glenwood MN
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers
  • 7 of 7 people found this instruction helpful
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!

Ice Bin Enclosure Cracked

  • Customer: George from Reeds Spring MO
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 7 of 8 people found this instruction helpful
As the previous users have stated, remove the ice tray, then remove the ice bin enclosure. Watch for the screws that are used to mount the enclosure.
As you slide the enclosure forward, go slowly, there is a wiring connector at the back, you will need to un-plug this connector. The solenoid assy is kind of tricky, as it is spring loaded, but easy to figure out. As previously mentioned, the auger yoke is on a shaft that has to be removed by turning it clockwise (reverse threads). Be careful with that, as it is hard to hold on to the shaft while getting the yoke off. Now remount the motor, remount the spring loaded solenoid assy, slide the ice bin enclosure back in a ways, then reconnect the wiring harness, slide it the rest of the way in, tighten the screws, and you are ready to make ice again. Approx 30 minute job.

Broken (froze) ice maker water valve.

  • Customer: richard from Little Suamico WI
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Wrench(Adjustable)
  • 8 of 11 people found this instruction helpful
1. Turn off fridge and Pull plug from wall.
1a. Turn OFF water supply!
2. Remove rear dust cover to gain access to water valve.
3. Mark power connectors(red/green) attached to water valve before removing them. Remove connectors.
4. Remove supply line from old valve.
5. loosen mounting screw holding old valve in place.
6. remove valve.
7. disconnect two plastic water lines from valve.
8. Cut 1/2 inch off the end of each plastic line to get to un-streached line. Make sure you have enough line to still reach valve!
9. Insert plastic lines FIRMLY into outlets of NEW VALVE to lock in place. outlets are different sizes so you can't reverse them!
10. Install new valve and tighten mounting screw.
11. replace/tighten supply line to new valve.
13. Replace dust cover!
14. Plug in, Turn on fridge.
15. Turn on water supply, bleed air out by drawing a glass of water at door, and check for leaks!
All Done!

Ice maker over flowing

  • Customer: ben from manhattan KS
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers
  • 8 of 11 people found this instruction helpful
My ice maker was overflowing and i realized that it was the water valve that needed replaced. unscrewed 1 nut, unhooked 3 water lines, unhooked electrical components and re-installed in reverse order. took about 10-15 mins.

freezer will not freeze or cool the ice box

  • Customer: David from Choctaw OK
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Socket set
  • 7 of 9 people found this instruction helpful
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson

noisy fan motor, fridge & freezer not holding temp

  • Customer: Paul from Joshua Tree CA
  • Difficulty: Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 8 of 12 people found this instruction helpful
I took off the ice maker, disconected the wiring, took out the back of the freezer and took out the fan motor. Harder than I thought because of all the wiring back there, light, fan assembly etc. After that it was easy, took out the old motor & installed the new one. Runs much quieter now, and the fridge & freezer are much colder.
I did this for less than the price of a service call by a repair shop.

Icemaker was giving crushed ice only

  • Customer: Bill from Flowery Branch GA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 7 of 9 people found this instruction helpful
First I rolled the fridge out and unplugged the power cord. I then removed the ice bin. There was one screw to the left under the ice bin rack holding it in. After removing that screw, I could pull the rack out far enough to disconnect the electrical connector. You have to squeeze the wings b-4 you can pull the connector loose. I put the rack on the countertop, removed two screws and the solenoid with plunger came out. I replaced the old solenoid, put everything back together, and realized I probably just saved myself $300. My Wife thinks I'm a Hero again. It works fine now.
All Instructions for the ASD2514ARA