The part that closes with the solenoid broke off and did not close the ice maker

  • Customer: Karen from Rocky River, OH
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required:
  • 17 of 19 people found this instruction helpful
I removed the two screws that hold the element in place. I then unscrewed the four remaining screws with a star screwdriver and pulled the element out and disconnected the wire. I removed the part containing the solenoid, spring loaded holder and the plastic closer. I did not need to replace the solenoid or the spring loading device only the round circular piece that opens and closes the ice door. I just snapped it into the spring loaded part and replaced everything as I had removed it. It was very simple. Your need the star screwdriver though for removing the screws.

Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.

  • Customer: Florentino from Windsor Locks, CT
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 19 of 25 people found this instruction helpful
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.

Vegetables kept freezing regardless of temp setting.

  • Customer: John from Leominster, MA
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 19 of 26 people found this instruction helpful
I noticed that the thin plastic flap was missing. I squeezed the housing, unsnapped and pulled. INstalling the new part was just the reverse. No more frozen vegetables.

Ice Maker broke at the begining of summer !!!!!!

  • Customer: Darrell from Pepperell, MA
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 17 of 21 people found this instruction helpful
The new Ice Maker Assembly arived in less than 24 hours. I was amazed that it came so fast.

I had already removed the old ice maker in order to get the modle number.

I just took two parts off of the old ice maker and quickly snapped them into place on the new ice maker. Then attached it to the refrigerator in less than 10 minutes. With in a few hours I had ice again !!!!!

I would definatly use partselect.com again.

The old motor wouldn't turn the fan.

  • Customer: Bob from Hesston, KS
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Socket set, Wrench set
  • 16 of 19 people found this instruction helpful
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Removal of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.

Ice maker stopped working

  • Customer: Ronald from Chardon, OH
  • Difficulty: Really Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 14 of 14 people found this instruction helpful
Since I had no water in the try I started with the valve first. That did not fix the problem so I replaced the Ice Maker assembly however that still didn't solve my problem. The only thing left was the relay that entergized the valve. The part number shows NLA so I googled the part number on the relay and found one at Mouser Electronics under PN:G2R-1A-T-AC120. The whole project took me several days to solve however the actual time involved was only about 1 hour.

overload relay switch/bad compressor--buzzing sound, ends with click, retries

  • Customer: Nathan from Garland, TX
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set
  • 15 of 18 people found this instruction helpful
Remove back cover. Disconnect power. Pull out overload switch off compressor. Remove capacitor. The overload switch i ordered came with instructions. What took the most time was figuring out if i dared installing it the way i thought best. The instructions, in my instance, were incorrect. My overload switch didn't have a terminal #1. Long story short, i looked at the circuit diagram it came with, and based on process of elimination based on terminal sizes, I put it together. But the instructions weren't accurate. All in all for the average DIY, not a bad repair at all. I am still afraid that my problem is the compressor, b/c even after the new part is installed it still occasionally tries starting but can't, and keeps retrying until it does. It is either a faulty relay switch or a faulty compressor. We'll see which one wins.

Old Icemaker noisy and stopped making Ice

  • Customer: Daniel from Rhinelander, WI
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 16 of 22 people found this instruction helpful
The old icemaker had a bad motor and would stall in the fill cycle causing my kitchen to flood on occasion.

The new one was so quiet, I thought it didn't work!

Anyway, one nutdriver and 5 minutes and I had the new one in there... It is so quiet, and I always have plenty of ice now!!!

Thanks!!!

Freezer and Fridge wouldnt cool

  • Customer: Janet from Hillsboro, OR
  • Difficulty: A Bit Difficult
  • Time to Complete: More than 2 hours
  • Tools Required: Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
  • 13 of 14 people found this instruction helpful
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!

Ice stripper broken on ice maker

  • Customer: Kenneth from New Braunfels, TX
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 14 of 18 people found this instruction helpful
I unplugged the fridge. Loosened the 2 top screws on the ice maker and removed the lower screw. I disconnected the wiring harness and removed the Ice maker. I removed the plastic timer cover in front. I then loosened the screws on the face of the ice maker and removed the broken ice stripper and replaced it with a new one. Re-tightened the screws on the face, installed the timer cover, plugged in the wiring harness, re-attached the ice maker. Plugged the fridge back in and walla, it was making ice in 30 minutes!

Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.

  • Customer: David from Cedarville, OH
  • Difficulty: A Bit Difficult
  • Time to Complete: More than 2 hours
  • Tools Required: Screw drivers, Socket set
  • 12 of 13 people found this instruction helpful
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.

Refrigerator Ice Maker stopped making ice.

  • Customer: Harold from Oakton, VA
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 14 of 20 people found this instruction helpful
(1) Removed the three screws which attached the ice maker to the freezing compartmnet wall in refrigerator; (2) Disconnected the power to the old ice maker; (3) Removed the old ice maker from the freezing compartment of the refrigerator; (4) Took the white front cover off of the old ice maker; (5) Disconnected the wiring harness from the old ice maker; (6) Removed the "ice making-stop arm" from the old ice maker; (7) Placed the items taken from old ice maker on to the new ice maker; (8) Reconnected the new ice maker to the power; (9) Placed the new ice maker in the proper position in freezing compartment of refrigerator and replaced the three screws. JOB DONE!

Door flap not opening correctly and noise when pushing button for water

  • Customer: Charles from Allen, TX
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Wrench set
  • 11 of 11 people found this instruction helpful
This repair was relatively easy due to the instructions provided and took about 15 minutes. Originally, I had bought a door flap thinking that was the problem (a small plastic piece on the flap had broken off) but after replacing that the assembly still would not allow ice flow. I then purchased the kit including solenoid and the repair worked. I had a bad solenoid all along. My suggestion is to replace the entire kit rather than one part as it is likely all parts need replacement.

Not defrosting the coils warming up the compartments

  • Customer: Steve from Marion, IN
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 12 of 14 people found this instruction helpful
Removed housing on the freezer side and removed the assembly by removing the two bottom clips and then unclipping the wire harness, two prong, and replaced as remvoved. Power was off of course. Watched for 24 hours and recovered housing and its been working great.

the ice/water actuator switch burnt out and was stuck on.

  • Customer: Jon from Nampa, ID
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 11 of 13 people found this instruction helpful
Removed the rubber cover over the actuator switch. Used a screwdriver to remove the switch, disconnected the wires. I then removed the switch from the mounting bracket using a small philips head screw driver. Installed the new switch on the mounting bracket then installed the switch onto the freezer door. The only difficult part was installing the rubber cover. Now I just need to repair the damage to my hardwood floors and carpet from all the water.