Water overflowing ice maker

  • Customer: James from Denver NC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 4 of 6 people found this instruction helpful
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.

Broken ice enclosure

  • Customer: Robert from Hinesville GA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 5 of 9 people found this instruction helpful
The ice enclosure was broken where the element is attached to the enclosure. There was some ice buildup in the ice bin and looks as if the auger got bound up and twisted the element attachment until it broke the housing of the enclosure. We got on line and fround the part at PartSelect. The selection process was very easy since PartSelect had all the parts pictured and described. We ordered the part first thing on a Monday morning and received the part Tuesday morning. We are very inpressed with the company and the fast service in receiving the part. Thank you. If the need arises we will order from you again and recommend you to friends.

The freezer doors was missing two shelves.

  • Customer: Edwin L. from Prospect Park PA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 3 of 3 people found this instruction helpful
Purchased two new shelves and installed them into the freezer door,. they just clipped in.

leaking ice maker,big chunks ot ice were forming and had to remove them 2-3 times a day

  • Customer: Linda from Johnson City NY
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 3 of 3 people found this instruction helpful
removed old ice maker by taking out a couple of screws in the back of freezer,when new ice maker arrived i saw that it didn't have the same hose apparatus as old one so I easily took apart old one then took apart new one and switched them out-very-- easily done for a 61 yr old lady I might add-- also had to reinstall ice maker arm off old ice maker as new one does not come with one Then installed new ice maker in freezer I am very very pleased,sure saved a lot of money doing it my self

Ice shoot door broke and would not open or close

  • Customer: Michael from Arlington VA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 3 of 3 people found this instruction helpful
Removed the drip tray and cover panel. Then removed shoot housing, replaced broken door and reassembled in reverse order. Easy as pie.

Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser

  • Customer: Kenneth from Newton Grove NC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 4 of 6 people found this instruction helpful
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.

automatic ice door would not open

  • Customer: Gerald from colonia NJ
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 3 of 3 people found this instruction helpful
removed the front panel on freezer door ,removed and disconnected panel ,removed panel containing solenoid,replaced with new solenoid. replaced all parts. works perfect..

fridge ouit cooling

  • Customer: danny from adelanto CA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 5 of 9 people found this instruction helpful
where the wires crossed at the start relay, 20 years of vibration allowed them to short out and burn out the start relay ..since i have 2 identical fridges i switched the run capacitor to determine it was'nt bad too...ordered a start relay wednesday nite and got it friday morning...cold fridge by noon...good service and the part was exactly the same as the original....

No water to icemaker

  • Customer: Philip from Mission Viejo CA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Wrench(Adjustable)
  • 3 of 4 people found this instruction helpful
Easy to diagnose problem because there was water to the water dispenser but none to the newly installed icemaker. Originally did attempt to clean the solenoid but found the plunger assembly damaged.

New part arrived sooner than I thought it would. Takes about as much time to remove the lower vent cover as to replace the valve. Remove the electrical plug from the wall, valve off the main water supply, remove lower vent cover, disconnect the supply hose from refrigerator valve assembly, remove one hex head mounting screw and you have both water valves in your hands. Identify the valve the supplies water to the filter and the one that supplies water to the icemaker/water dispenser. Then confirm which plastic water supply line goes to the water dispenser and which goes to the icemaker. Hose diameters are different but it is good to know. Disconnect the plastic water supply lines from both the ice dispenser and the icemaker portions of the valve. Replacement solenoid valve does not have thread on type compression fittings. Snip about an inch off of each hose and then press into the appropriate valve orifice.

Making sure the plastic supply lines do not get crimped, remount the valve assembly, reattach the supply hose, valve on the water and check for leaks. No leaks, reinstall dust cover and plug the refrigerator back in.

Move the unit back in place and then take a long deserved beer out and have a celebratory toast for a job well done.

Replace ice enclosure

  • Customer: Charles from Columbus OH
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set
  • 3 of 4 people found this instruction helpful
The plastic around the the drive motor on the ice enclosure fatigued and broke. Couple if screws and the whole thing came. Replacement was easy, one screw under the rail of the ice enclosure, then it slides out. Swap the parts and reinstall.

broken light switch

  • Customer: Richard from West Warwick RI
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 4 of 7 people found this instruction helpful
followed the instructions provided and that's it!

oven light burnt out

  • Customer: William from Schwenksville PA
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 3 of 4 people found this instruction helpful
1. Unscrewed glass cover on bulb
2. Removed old bulb
3. Screwed in new bulb
4. Replaced glass cover
5. Mixed drink & baked cupcakes

Freezer too warm; noticed sides of refrigertor were warm

  • Customer: W from Nellysford VA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
  • 3 of 4 people found this instruction helpful
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.

Refridgerator was missing a glass freezer shelf

  • Customer: Janet from Fort Collins CO
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 3 of 4 people found this instruction helpful
Took the glass out of the package, attached the shelf trip and popped that sucker in!!
Easy....easy....easy!
THANKS!

The plastic ring that is the connection between the drive motor at the back of the freezer compartment to the auger in the ice bin shattered when my wife was dispensing crushed ice.

  • Customer: Larry from Anchorage AK
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 3 of 4 people found this instruction helpful
Part selects cataglog for parts selection was very easy to use and the online service and delivery was great.
When I got the part, it was not apparent on how to remove the auger so that I could insert the new connector. There were about about 8 visible screws, with star drive heads that I fortunately had a screwdriver that fit, and I could not tell if I had to remove all of them or only a couple.
I ended up removing all, but still could not separate the dispenser portion which held the front of the auger from the back of the ice bin. I finally figured out that the dispenser door trip lever had to be disconnected and I almost lost it when I removed the metal clip that attached it to the outside of the ice bin when the spring loaded lever tried to unwind. I managed to hold it in place, separate the dispenser holding the auger from the rest of the ice bin and replace the connector. I them got the pieces back in place and was able to refasten the spring loaded lever and then replace the screws.
If the spring loaded lever had unloaded, it would have been tricky to try to replicate the amount of turns (load) on the spring tension.