old valve was cracked
remove the back plate, removed the screw holding the valve, removed electrical wires and water tubing. installed new valve. very simple. also i received the valve in one day. thank you
Parts Used:
Secondary Water Valve
  • Duston from Lawton, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door would not self close tightly
Remove two screws from top door hinge.
Remove door from unit
Remove old broken plastic cam 1 screw
Replace new door cam tighten 1 screw
Reinstall door and top hinge screws.
Parts Used:
Door Closure Cam Kit
  • paula from julian, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cam snapped in half on bottom of door
Super easy - emptied door of all food, unscrewed bracket from top of door, lifted door off and set aside. Broken cam removed, new one screwed in, and lubed with some Vaseline. Set door back in new cam, screwed bracket into the top, and good to go. I was kinda worried about shopping from PartSelect since I had never heard about them, but the part was here in less than 2 days. Pretty awesome little company.
Parts Used:
Door Closure Cam Kit
  • Mason from Tallahassee, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Door Solenoid was Broken
I removed the two screws on the Ice dispenser housing and dropped it down. I catalogued all the electrical connections on a piece of paper for reassembly and basically followed my nose. I gave my wife the honor of testing it and I held my breath. Replacing this part was a breeze and it functioned perfectly when the job was completed. I wish I had done this three years ago when it failed! Thanks very much !!
Parts Used:
Ice Door Solenoid
  • norm from williamsburg, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker dripped water into ice bin, freeezing into large block of ice,
turn off water and unplug fridge. remove ice maker bottom mounting screw. just loosen the 2 top mounting screws. unplug wire harness from back of fridge. remove old icemaker from freezer compartment. once removed, salvage square endcover and reinstall on new maker. unfasten wire harness from old maker and reinsatll on new one. reinsert thermal wire in new ice maker holding bracket. remove second wiring bracket and reinstall on new maker to hold remaining wires (not mentioned on "how to-" video). remove old ice maker on/off bale and reinstall on new one. remount new maker to top mounting screws, reinsert harness plug into fridge. replace bottom screw,
Parts Used:
Replacement Ice Maker
  • charles from PHOENIX, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Parts Used:
Run Capacitor
  • riley from CAVE CREEK, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker Auger
Wow! less Than 15 mins to install, called partSelect and within two days the Auger arrived and with handy socket it was done!
Parts Used:
Ice Maker Auger and Crusher Blade Assembly
  • Marshall from Marrero, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
This is almost embarassing but you asked....
Once the part arrived, which was very quickly BTW..all I had to do was remove the old filter and then just screw the new one into place....Now I just happen to be both female and blonde but was able to get the job done in less than 15 minutes (that includes opening the box) and with very little water dripping from the old filter!!! Looks like I could work as the Maytag repair woman soon!!
Parts Used:
Refrigerator Water Filter
  • laurie from gold canyon, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door would not close properly
Removed the door by taking 3 screws out of the top and lifting straight up, then replaced with the new parts and very easily replaced the door, worked ike a charm, if i didn't know any better it was like factory new
Parts Used:
Door Closure Cam Kit
  • Sarkis from Havertown, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The door made a loud noise on opening and closing.
Emptied the door.
Removed the door, top bolts first.
Lifted out the door.
Installed new cam at the bottom.
Set the door back in place.
Bolted the top hinge back on.
Smooth!

The part came quickly and was the right one. You can't imagine how many outfits lose it here. Well done and thanks.
Parts Used:
Door Closure Cam Kit
  • Dennis from Kerrville, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replacing the bulb in the freezer side
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.

Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Parts Used:
Light Bulb - 40W
  • Yafa (and David) from Bothell, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaky ice maker - non-stick coating had failed
replaced the entire ice make - 3 screws and a squeeze -off connector and it's out. Reverse to re-install... except that the fill tube had iced up. To thaw the fill tube: unload freezer section (leave food in fridge, but keep door closed), remove ice maker. Boil water, dip drill bit (dull end) into hot water, swirl around, insert (dull end) into to fill tube. Depending on how hot you got it, maybe a tablespoon of ice will melt. Repeat many times - fill tube is about 14" long! Do not use anything sharp - you will nick the tube and ice will form causing you to repeat this procedure. Do not try to break the ice - let the heat work. It took me about 30 minutes to thaw the whole thing - it made a nive gasping noise when the final plug opened up. Re-install ice maker.
Parts Used:
Screw Replacement Ice Maker
  • Robert from Sunnyvale, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice cubes in bin frozen into big lumps due to water leaking into bin from icemaker. Lining of icemaker cube tray worn and damaged allowing leak.
Pull refrigerator out from wall to shut off water and power. Remove ice bin, pulling front down then out. Remove screw at bottom of icemaker, then pull down to release two clips, Pull out a couple inches to get hand behind icemaker to release wiring harness connector. (squeeze top and bottom to release clips). Remove unit. Remove wiring harness and wire bail from old unit and install on new unit. Reverse steps to install new unit. Make sure ice bin is fully inserted, or unit will not function.
Parts Used:
Replacement Ice Maker
  • Ross from Sun Lakes, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken valve due to outdoor storage and freezing
After locating broken valve ordered part online.

Replacment was very straight forward and directions were easy to follow. At first I was concerned about slip in fittings insted of threaded compression fittings, but they went in easy and sealed properly.

Fridge was pulled out, valve replaced, water flow tested and fridge pushed back in within 30 minutes.
Parts Used:
Secondary Water Valve
  • John from Friday Harbor, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator stopped running
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Parts Used:
Run Capacitor
  • Barbara H. from South Hill, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!