Motor squeal
I didn’t do the repair because the new motor had a female pigtail connector while the original motor has male connection. It came with wire clamps but didn’t want to cut wires to make repair. The pictures online show a male connection. Put the old motor back in and now it works fine.
Parts Used:
Evaporator Fan Motor Kit
  • Mark from Partlow, VA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Easy Fix
Was really basic, simply slide off the old caps, slide on the new ones, put the shelf back where it goes, push down lightly so as to not snap the new caps, and viola, complete. No more than 2 minutes worth of work. Great part at a great price, shipping was more than the part itself so I bought 2 of each. Only problem I ran into was that I ordered the top shelf caps instead of the bottom the first time, so I had to reorder.
Parts Used:
Door Shelf End Cap - Left Side Door Shelf End Cap - Right Side
  • Damien from Oneonta, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer frosted up, refrigerator compartment heated up
I removed the housing at the top of the refrigerator compartment that contained the reefer light and temperature adjustment knob. This required a small nut-driver. Inside, I found the old defrost control, unplugged it, unscrewed it with a Phillips screwdriver, and replaced it with the replacement part. Then I replaced the housing to its original position.
Parts Used:
Defrost Timer - 60Hz 120V
  • James from Hanover, ME
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer too cold
Removed the housing with the light, 4 hexhead screws. This exposed the defrost timer, removed 2 hexhead screws, electrical connector and reassembled the unit.

Great resource and service, thank you.
Parts Used:
Defrost Timer - 60Hz 120V
  • Curt from Maple Grove, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old Defrost Timer Noisy During Operation
First I removed the plastic grill (pulled out, no screws) from bottom of refrigerator, then I removed electrical plug & two screws from old timer (timer located on the front inside left lower side of refrigerator). Installed in reverse order.
Parts Used:
Defrost Timer - 60Hz 120V
  • Vernon from Granada Hills, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door shelf retainer bar end caps broke off at insertion point.
Removed plastic male parts. Inserted new end caps onto old retainer bar. Inserted all into door. A snap, but I didn't need to order the retainer bar after all - the old one was the perfect fit and the one I ordered was way too long. I returned the new retainer bar, and the shipping was more expensive than the part.
Parts Used:
Door Shelf End Cap - Left Side Door Shelf End Cap - Right Side
  • Nell from New Orleans, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer icing up and refrigerator section not cold
Removed four screws for cover on refrigerator temperature controls, unpluged old timer and pluged in new timer. Replaced cover and screws.
Parts Used:
Defrost Timer - 60Hz 120V
  • Les from Fenton, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
only freezer was cold, frig warm
removed all items from frig.. removed shelves, loosened one screw on each slide bracket and moved them down and out of the way of the rear panel....removed 6 screws in rear panel...removed all ice on coils with a heat gun...located defrost stat, replaced...crimped wires...re-installed rear panel and shelves! On left side of frig. in front bottom..located defrost timer..removed trim piece, loosened 2 screws....removed and replaced defrost timer...plugged in the frig. and it started!!!!
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Edward from Middletown, DE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator in my new apartment was missing the brackets that hold the bars so that things don't fall off of the door shelves. It was missing several off of the refrigerator door and one off of the freezer door.
I just had to make certain I had the correct end-cap for the correct side. I placed the two little curved pieces into the slots and applied some downward pressure (gently) onto the end-cap till I heard it "snap" into place. You could then see that it was held in place securely. I did first one side, then fed the bar into it, then placed the other side onto the the bar; inserted the end-cap and secured it in place.

HINT: I myself mistakingly ordered the same exact end-cap for both the freezer and the fridge doors. I was unaware (I failed to check), that the end-caps for the freezer are not the same end-caps as the ones for the fridge door. My refrigerator uses three different end-cap sizes; one size for the actual fridge door and two additional different sizes for the freezer door. Not wanting to exchange it, I used the one I ordered anyway. It still works, but makes the bar protrude into the freezer more than it would have, had I ordered the correct size.

SPECIAL NOTE: This company got the correctly ordered products to me within a couple of days. I would definitely order from them again without hesitation. I am very happy with the product and service. Smooth.
Parts Used:
Door Shelf End Cap - Left Side Door Shelf End Cap - Right Side
  • Lisa from Long Beach, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator wasn't cold enough.
I removed the plastic shroud on the ceiling of the refigerator, unscrewed and unplugged the old defrost timer, and replaced it with the new one. I reinstalled the shroud with the new timer installed.
Parts Used:
Defrost Timer - 60Hz 120V
  • John from San Diego, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge not cooling
My fridge side had warmed up to 70 degrees but the freezer side was still cold. The coils inside had iced up. After thawing with a hair dryer, it froze back after another week. I removed the old defrost thermostat and wired the heater strip directly and turned on the defrost timer. It began melting the ice so that ruled out the heater strip being bad. I couldn't get a reading with my ohm meter on the defrost thermostat so I took a chance and bought the part. Installation was a breeze and it fixed the problem.
Parts Used:
Defrost Thermostat
  • WESTLEY from HATTIESBURG, MS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was freezing but refridgerator was warm. Checked fan and it was not turning.
Unplug fridge. Removed 2 nuts to get the vent plate off and two more nuts to get the motor mount off. Removed fan blade and then the fan motor. I put the new motor in and put everything back as it was. It was very easy. I had items in the freezer, so I didn't turn the fridge off other than to replace the part. It took about 6 hours for the fridge to reach optional temps because I didn't get to defrost and the fridge had to work it out on it's own. If you don't need the freezer then you should turn the refridgerator off for at least an hour and open the doors so the coils can defrost and any ice blockage between the freezer and fridge portion can melt away as well.
Parts Used:
Evaporator Fan Motor Kit
  • Jerry from PHOENIX, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer was warm
Top freezer took off the panel in freezer and melted the ice around coils and found the defrost thermostat and replaced with the new one. Just followed the instructions from your video on line. Freezer works just fine now. Refrigerator is 38 years old.
Parts Used:
Defrost Thermostat
  • Carol from OSHKOSH, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Repaired Oven Range Light Bulb
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
Parts Used:
Light Bulb
  • Alan from SAN MATEO, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Parts Used:
Evaporator Fan Blade
  • gary from ARANSAS PASS, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the WRT13CGBY0