Light bulb failure
Received the part the day after ordering. Appreciated the quick service and repair took less than a minute.
Parts Used:
Light Bulb - 40W
  • Grant from Alexandria, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
compressor will not start - when you turn it on - it hums for a few seconds and them you hear a click sound (the overload opens) and the hum stops
be sure the power cable is NOT plugged into an electrical outlet - removed the cover on the bottom rear of the refrigerator - using a flat blade screw driver pry the cover off the side of the compressor - remove the old relay - remove the wires from the old relay and install them on the new relay in the same location - install the new relay on the compressor connections - snap the cover back on the compressor - replace the cover - power the refrigerator on - the compressor should start and run normally
Parts Used:
Refrigerator Compressor Start Relay
  • Cliff from Metairie, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
light switch sticking
I watched the video and thought "I can do this". Made some notes and then proceeded to remove the old switch and replace with the new one. Thank you.
Parts Used:
Refrigerator Door Switch
  • Paula from Rush, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Light did not come on (bad bulb!) on TC18KL
I have never before seen a bulb with the filament intact not light. If the bulb's filament seems intact, screw the bulb into a known working lamp and see if it lights. When screwing it back into the socket in the fridge, it takes a bit of extra effort to fully seat (until it does, it won't light!). For replacing the switch, I unplugged the unit, used a paint scraper and worked it under the switch bezel from the right side. A bit of moxie, and the switch came out. The replacement switch had a different spade contact spacing than the original. I used a pair of scissors to cut the rubber bridge between the two switch wire connectors so I could connect to the new switch. In the end, it turned out to be the bulb. NOTE: The Model TC18KL is _not_ listed! What I finally found that the number "P7803211WL" on the sticker is actually a manufacturing code. Found this out by searching, and Sears' part search came up with matches.
Parts Used:
Refrigerator Door Switch
  • Louis from Beloit, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Light socket not working
Pull out plastic cover #13of refrigerator part discription (temp. control and light socket), snap out old light socket and replaced with new light socket. light is now working.
Parts Used:
Light Socket
  • Romeo from Edinburg, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Switch didn't work
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Parts Used:
Refrigerator Door Switch
  • Don from Laramie, WY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
Was this instruction helpful to you?
Thank you for voting!
exchange of defective light rocker switch
1)pry out the old/defective light rocker switch with a screw driver (flat head) and pull out the cables 2)unplug two connectors at the end of light rocker switch 3) connect new light rocker into two connectors 4)push the wires inside and put back new light rocker switch
Parts Used:
Refrigerator Door Switch
  • Steve from River Edge, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Light in the refrigerator didn't work
I did exactly as the video showed. I popped out the old switch, disconnected the two terminals, connected the new switch and put it back. The light now works! The refrigerator is over 25 years old and the switch works! What a great website this is. Couldn't of done the job without Partselect's help.
Parts Used:
Refrigerator Door Switch
  • Anthony from Fairport, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
refridgerator was not cooling to the proper temps and finally would not cool at all
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Parts Used:
Condenser Fan Motor Kit
  • John from LAS CRUCES, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Ice bin had been lost
1. Removed part from packaging. 2. Cleaned part with foodsafe cleaners. 3. Rinsed thoroughly. 4. Dried thoroughly to prevent frost. 5. Placed bin in freezer. 6. Turned on ice maker. 7. Waited. 8. Discarded first batch to clear supply line. 9. Waited. 10. Enjoyed ice. 11. Provided these inductions.
Parts Used:
Ice Bucket
  • Bruce from Fort Wayne, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
shelf retianer bar kept falling off causing items to fall off and spill
Removed old broken plastic retainer clips and slid new ones into the retaining bar then lined up the prongs on the retainer clips to the holes in the door liner and pushed into place. They will snap in and lock in place. Make sure the curved section of the clip faces inward toward the shelf and the long ears on the plastic clip slide into retaining bar. If the retaining bar is bent or the ends are curled under you may have to reshape it back with some needle nose pliers or if bent too badly replace the aluminum bar as well as the clips. Hint: For an easier install you can snap one clip into the door liner first, then slide the bar over it. Then line up the other side and push the clip into place.
Parts Used:
Door Shelf Retainer
  • Robert from Drytown, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
Was this instruction helpful to you?
Thank you for voting!
Fan motor worn out
My Son who is not an appliance repairman did it for me. He had some difficulty getting the nuts and bolts loose mainly. Sorry I'm not much help other than that! I would like to compliment you on your fast service, first time ordering from you and it was for an older model refrigerator that my repairman said he couldn't find. It's working fine now and I'm a satisfied customer!
Parts Used:
Condenser Fan Motor Kit
  • Myrna from Decatur, IL
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
Was this instruction helpful to you?
Thank you for voting!
condenser motor broke
opened box,read directions,took out bad motor,installed new one.PRESTO CHANGO way to go.
Parts Used:
Condenser Fan Motor Kit
  • patrick from livonia, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
wouldn't make ice, door seal was hot to touch, warm in fridge.
I folded in half twice! and took the back off the fridge(cardboard) and took one brace off and just took the screws off the fan from the other two braces. Turned the fan enough to get at the wires for the fan and cut them off an inch from the old fan, stripped the insulation and wire nutted them to new fan. Make sure they don't interfere with the new fan and put the new fan in place put the screws in and we're making ice and cold fridge again.
Parts Used:
Condenser Fan Motor Kit
  • Dale from Sterling, AK
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Socket set
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped cooling compressor did not cycle
unplug power! Remove the screws from lower panel on back of refrigerator. Lift wire mount out of back panel. Capacitor is mounted directly to the relay and overload switch located on the left side of the compressor. Remove the spring clip holding the capacitor in place and pull the old capacitor out. Plug in new capacitor and replace spring clip. Use vacuum to remove dust from drip pan and wipe fan blades clean. Replace wire into slot on back panel and replace screws. Remove front coil cover below freezer door. vacuum dust off coils and replace cover. Plug refrigerator in and enjoy cold beverages. Relay and overload kit were not required for this repair.
Parts Used:
Run Capacitor
  • james from indian springs, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!