ice stalactites were drooling out of the icemaker and gumming up the cubes in the receiving tray.
I first shut off water flow to the fridge. Examination of the package (which was not exact in appearance to the original) demonstrated that the electrical connectors were well-insulated so I arrogantly and successfully proceded without disconnecting the power. My fridge is old enough that the model doesn't appear exactly on anyone's list so I wasn't alarmed that it took an extra 10 minutes or so to noodle out how to adapt the slightly different inlet cowling and electrical cord with extension, but the device is pretty simple. Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use. The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap. After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.
Refrigerator would not get cold although condensor fan worked. The compressor did not come on.
I replaced the capacitor first but the compressor still did not come on. After trying the new capacitor I removed the old board( marked the connectors just in case) then installed the new board. The major difference on the new board was the grounding wire which was simple to connect. The old board didn't have one. Once installed everything worked fine. The directions were easy to follow. I ordered the parts late Sunday night and I received the parts by Wednesday! That was fast. Thanks for the help, and this was much cheaper than calling the appliance service.
I unplugged the electrical connection. Then I removed the 2 screws holding the icemaker in place. I lifted out the old icemaker unit and put the new one in place. Then put the 2 screws back in and plugged in the new unit.
The icemaker started making ice very soon after turning the unit on.
Removed rear and front grills,brushed and vacuumed area- probably caused the fan motor to fail- unplugged fan, removed fan,motor,and shroud in 1 piece, carefully slipped fan off motor shaft, unscrewed shroud and motor. assembled in reverse order. Frige is in tight area, .I'll now roll it out and clean often
Recessed door on ice dispenser would stay open causing the freezer to frost up
I inserted the tip of a very small screwdriver from a eye glass repair kit into the three small holes under the panel near where the ice is dispensed. I never would have known about this simple procedure if it wasn't for the feedback you post from your parts cumtomers. Once I did this the front panel with the buttons on it poped off and it was just a matter of removing a few screws at that point. The wires from the new solenoid easily plugged into the board on the front panel. I would recommend changing the screws at the same time. The old one's worked but they were rusty. I feel the solenoid was my only problem but I changed all the parts in between the dispenser door and the solenoid just to be sure.
Our refrigerator stops delivering ice both crushed and cube. The ice bin was full. I first thought the delivery motor was bad and then the water dispenser in the door stopped delivery. Decided at that point it was either the door panel swith board, cable or the main circuit board on the back of t
After further diagnosis decided the main circuit board was the likely culprit. Ordered a new one from PartSelect. It came in 2 days and took less than 30 minutes to install. Unplugged the refrig. Removed the old board cover with a nut driver. Removed the wiring cables (note their location on the board) and also there were a couple of cable plugs on my refrig that were not not hooked to anything on the board. Snapped the old board out and the new board in. Reinstalled the cables and then the board cover. Plugged the refrig in and back in business. PartSelect is a great website! The speed of delivery and available information just saved me $500 to $600 from a appliance repair shop.
dropped something on the light switch and it broke off
we just pried out the old switch and pulled it out the rest of the way with a pair of needle nose pliers. Pulled off the wires on the broken switch and reattached to the new one and just slid/clicked it back into the hole.
After advise from the expert, he was adamant the motherboard was the (via symptoms)problem. After receiving the replacement board (via FEDEX), I followed the easy to understand instructions. I did number the electrical plugs and mapped the connections on paper. The key to the rapid fix was to carefully read all of the instructions to verify which (if any) wires needed elimination, which in my case was none. I will definitely use this service in the future as the expense was affordable and after research, I estimate a savings between 55% to 60%.
refrigerator/freezer defrosting completely for no reason
Unplugged refrigerator and used a screwdriver to remove access panel on rear of refrigerator to expose "mother board". Unplugged connectors (6 total) and using needle nose pliers released two retainers to remove mother board. Installed new mother board snapping it onto the two retainers and plugged the connectors onto the new mother board. Plugged refrigerator into outlet, refrigerator came back on, automatically reset it's temperature settings and has been working fine since. Total time, less than 15 minutes. Money saved, hundreds of dollars!
It appeared that the helix lock wore out first, then the cutter teeth dug into the side of the plastic housing. Then the cup drive broke in half from the helix being jammed. Removed the ice bin from the refrigerator. removed 4 screws around the edge of the bin. Pry open clips that hold the auger assembly in place. Remove the clip from the end of the auger. Pry old plate helix lock from holder. Pull out helix auger removing cutters and keeping everything in order. Replace old plate helix lock with new one. Replace cutters in order and tighten nut and install clip. Put new cup drive on end of helix. Snap assembly back together. Replace screws.
Not cold & saw ice accumulated on freezer back panel
-Disconnect the power supply wire& turn temp control inside refrigerator to 0! -15 mins spent on remove (5 screws) the back panel inside freezer, melt ice then replace the heater (2 screws) on the bottom! Black wire on left & pink wire on the right! Make sure both end has good connection to the heater!
-30 mins to drain all water from the bottom (back side) of the refrigerator, suck & clean all dust & dirt from the front & back side!
-Set both temp control knots to 5 & put back all the food!
-If no ice build up on the panel after 10 days & then the repair is good!
went to your website and viewed exploded view to find the sensor( there are two I just picked one to replace for now), pried the cover off carfully and pulled out the sensor. I snipped the wire in the middle leaving plenty to work with. I shortened the wire on the new piece, spliced the wires together and with some 3M rubberized, tape wrapped them up, replaced the sensor back into the cover and snapped in place.
Ice door would not open far enough, ice would get stuck in chute
First remove about 30 screws w/nutdriver that are hidden under door seal then inside of freezer door will come off. Second remove about 10 screws that hold dispenser assy to the inside of door, then support the unit with tape so you don't damage the wires that connect it. Third, pop touchpad loose, then remove three sets of wires plugged into the circuit board. Fourth, remove four screws that hold the ice chute and light assy. Fifth, now remove the 3 screws that hold solenoid. These three screws that hold the solenoid will be very rusty, you may want to replace these also. I went ahead and replaced all the related parts because they are so hard to get to. Also took the opportunity to clean in here with bleach to remove all the black mold and rust. NOTE: when reassembling the inside of the freezer door to the outside of the door you must loosely attach the door on both sides in the middle first, then the top and bottom. Add some more screws on each side and tighten them all. Now you must check to be sure that the door is not racked. If the door is not sealed at the top or bottom, loosen the screws and twist the door a little and tighten screws and check door again for proper seal. Spent more time adjusting door to seal right than doing the actual repair.
The old filter twists out and the new one twists in. The hardest part was bleeding off water thru the dispenser to make sure all the air was out of the line.