Noise coming from defrost timer

  • Customer: Thomas from Pottstown PA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 8 of 10 people found this instruction helpful
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.

Freezer and Fridge wouldnt cool

  • Customer: Janet from Hillsboro OR
  • Difficulty: A Bit Difficult
  • Time to Complete: More than 2 hours
  • Tools Required: Nutdriver, Pliers, Screw drivers, Socket set, Wrench set, Wrench(Adjustable)
  • 7 of 7 people found this instruction helpful
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!

ice maker was leaking water

  • Customer: Sandra from Temecula CA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 8 of 11 people found this instruction helpful
Parts went right into place as the pictures showed and was working again in about 30 minutes. The only thing that wasn't working was the ice took forever to make, but solved that problem by turning up the temp in the freezer.

Condenser fan motor seized

  • Customer: Benjamin from Daytona Beach FL
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers
  • 6 of 6 people found this instruction helpful
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.

Scratches in Surface

  • Customer: Michelle from Richardson TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 7 of 9 people found this instruction helpful
This product comes in a bottle with a brush like Liquid Paper. It goes on incredibly easy. A second coat might be needed. I wanted to prevent rust from setting in so I covered the scratches and dings. The paint is a little brighter since my washer is 10 years old but it still looks great.

socket melted with bulb in it.

  • Customer: martin l. from JACKSONVILLE, IL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 7 of 9 people found this instruction helpful
plastic warped in ,spaced out and, the socket snapped back in place.

fan had stopped-freezer not performing etc.

  • Customer: George from Glenwood MN
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers
  • 6 of 6 people found this instruction helpful
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!

I had frost build-up in the freezer.

  • Customer: David from Arnold ME
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 7 of 10 people found this instruction helpful
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).

Water valve failed, flooded kitchen

  • Customer: James R from Valley Springs CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Wrench(Adjustable)
  • 6 of 7 people found this instruction helpful
Turned off water supply and unplugged appliance. Removed lower panel on back of refrigerator with 1/4 " nutdriver. Then removed supply line, and line to icemaker. removed valve from back panel and replaced with new valve. wrapped water connections with teflon tape, turned on supply line, checked for leaks, everything o.k..Replaced back panel and in 45 minutes had first drop of ice. Job requires moderate mechanical ability and minimum tools. Saved a PANT load of money by doing it myself. VERY satisfied with Partselect.com

ice maker stopped working

  • Customer: Larry from Mount Airy NC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 5 of 5 people found this instruction helpful
popped front cover off and found a broken gear.ordered part,took one screw out to replace gear.thats all there was to it.ice maker is working perfectly!thanks to you Partselect!

freezer will not freeze or cool the ice box

  • Customer: David from Choctaw OK
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Socket set
  • 6 of 8 people found this instruction helpful
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson

Water began to leak under the refrigerator. Source looked like it was coming from control valve suppling water to ice maker and water dispenser.

  • Customer: jesse from hacienda heights CA
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 6 of 8 people found this instruction helpful
Followed instructions supplied. It was relatively easy and the parts fit exactly right. Sears wanted twice as much for the part and service would have charged me another $100 to come to my home. I saved over $100 doing the project myself.

Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always

  • Customer: JAMES from Middleboro MA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 5 of 7 people found this instruction helpful
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels

ice maker, intermittent hollow cubes, then no ice

  • Customer: paul from madison WI
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench(Adjustable)
  • 5 of 7 people found this instruction helpful
I was not sure what was causing the problem, I thought at first it was low water pressure causing the hollow ice cubes. After some trial and error testing I figured a likely cause could be the water valve in the ice maker itself. I replaced that part rather easily using the existing fasteners in about 15 or 20 minutes. The ice maker has been working flawlessly since the repair.

The refrigerator leaked water every time the ice maker filled.

  • Customer: Robert E. from Darien IL
  • Difficulty: A Bit Difficult
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 5 of 7 people found this instruction helpful
The problem was discovered to be a cracked fill tube head, This part extends behind the refigerator and is VERY vulnerable to breakage when the box is pushed backagainst a wall space! Placing a shim under the vertical part of the fill tube fixed the problem even without replacing it with the new part. So, now I have a spare!