Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always

  • Customer: JAMES from Middleboro, MA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 8 of 10 people found this instruction helpful
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels

condenser fan stopped working

  • Customer: Steven from Brigham City, UT
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 8 of 10 people found this instruction helpful
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.

Freezer too warm; noticed sides of refrigertor were warm

  • Customer: W from Nellysford, VA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
  • 7 of 8 people found this instruction helpful
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.

I had frost build-up in the freezer.

  • Customer: David from Arnold, ME
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 9 of 14 people found this instruction helpful
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).

freezer will not freeze or cool the ice box

  • Customer: David from Choctaw, OK
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Socket set
  • 7 of 10 people found this instruction helpful
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson

compressor didnt turn on

  • Customer: gerardo from el monte, CA
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 10 of 19 people found this instruction helpful
changed the starter connected to the compressor

ice maker, intermittent hollow cubes, then no ice

  • Customer: paul from madison, WI
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench (Adjustable)
  • 6 of 8 people found this instruction helpful
I was not sure what was causing the problem, I thought at first it was low water pressure causing the hollow ice cubes. After some trial and error testing I figured a likely cause could be the water valve in the ice maker itself. I replaced that part rather easily using the existing fasteners in about 15 or 20 minutes. The ice maker has been working flawlessly since the repair.

Condenser Fan Motor seized up

  • Customer: Peter from Herndon, VA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 5 of 6 people found this instruction helpful
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!

The Ice maker would not work.

  • Customer: Jerry from Boulder, CO
  • Difficulty: Easy
  • Time to Complete: 1- 2 hours
  • Tools Required: Screw drivers
  • 13 of 30 people found this instruction helpful
We rolled the refrigerator out away from the wall and it was obvious where the break was located. We took out the old water spout for the ice maker and replaced the tube and the tubing from the solenoid. We turned it on and soon we had water dripping everywhere. We unloaded and defrosted the freezer which got all of the remaining ice that was stuck in there. We put everything back together. I read in some instructions in the manual that it might take 24 hours for the ice maker to reprogram itself and start producing ice. I was only about 12 hours and we had ice again and everything worked well. You really do not have to disconnect the water from the main line, the solinoid controls that part of operation and turns the water off until the ice trays are free and clear.

JLB

The Freezer defrosted and everything on the top and the bottom spoiled

  • Customer: Jorge from Miami, FL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 6 of 10 people found this instruction helpful
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burned. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.

Replacing the bulb in the freezer side

  • Customer: Yafa (and David) from Bothell, WA
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 5 of 7 people found this instruction helpful
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.

Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.

Freezer would periodically allow things to partially thaw out

  • Customer: Dana from Canyon Lake, TX
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 4 of 5 people found this instruction helpful
First, I removed the two thermostat knobs, then the snap-on plastic cover. Then, I removed the 4 screws holding the housing for the timer, thermostats, etc., and dropped it down enough to remove the timer and the wiring harness going into it. Installing the new one was the same process, in reverse. Quite simple!

Refrigerator quit cooling and the freezer wasn't freezing anything

  • Customer: Tonya from Grand Prairie, TX
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Socket set
  • 4 of 6 people found this instruction helpful
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.

Fill tube on the icemaker was leaking.Looked at sears repair parts list and part was $62. I found the same part here for $4.99. Very easy to just remove the old part and replace it with the new. I also received the part in two days. Amazing!!!!

  • Customer: Walton from Woodland, PA
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers
  • 3 of 3 people found this instruction helpful
Simlpy removed two screws to remove the old part. replaced the new part and put the two screws in. Job finished.

Ice water valve leaking

  • Customer: Byron from Steamboat Springs, CO
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Pliers, Wrench (Adjustable)
  • 3 of 3 people found this instruction helpful
Removed two screws holding valve, removed two 1/4" water lines. disconnected wire clip from old valve.
Installed new valve, connecting water and electrical with ease.
Absolutely Simple!